Beam splitter ||<tablewidth="1202px" tableheight="156px">Stage ||Description ||Relevant log entries || ||Top Filter ||At 25 ºC it's possible to use it to set the keystone at nominal ([[http://klog.icrr.u-tokyo.ac.jp/osl/?r=8125|8125]]), but at 24.5 ºC or lower it's not ([[http://klog.icrr.u-tokyo.ac.jp/osl/?r=8645|8645]], [[http://klog.icrr.u-tokyo.ac.jp/osl/?r=11465|11465]]). ||[[http://klog.icrr.u-tokyo.ac.jp/osl/?r=8125|8125]], [[http://klog.icrr.u-tokyo.ac.jp/osl/?r=8645|8645]], [[http://klog.icrr.u-tokyo.ac.jp/osl/?r=11465|11465]] || ||Standard Filter ||It's been at its lowest position since the temperature was 25 ºC.|| || ||Bottom Filter ||So far it's been working, but we haven't tried using it at all every temperature condition. || || |
== Beam splitter == === Top filter === * '''Range''' * '''LVDT:''' [ -2500 , +4900 ] µm ([[http://klog.icrr.u-tokyo.ac.jp/osl/?r=7694|7694]]). * '''Stepper motor:''' [ -1,400,000 , +1,400,000 ] steps ([[http://klog.icrr.u-tokyo.ac.jp/osl/?r=7694|7694]]). * Temperature when measured: * Observations * At 25 ºC it's possible to use the fishing rod to set the keystone at nominal position ([[http://klog.icrr.u-tokyo.ac.jp/osl/?r=8125|8125]]). * at 24.5 ºC or lower it's not ([[http://klog.icrr.u-tokyo.ac.jp/osl/?r=8645|8645]], [[http://klog.icrr.u-tokyo.ac.jp/osl/?r=11465|11465]]). |
Line 11: | Line 15: |
=== Standard Filter === * Range * '''LVDT:''' [ -700 , +700 ] µm ([[http://klog.icrr.u-tokyo.ac.jp/osl/?r=3358|3558]]). * '''Stepper motor:''' [ -870,000 to +835,000 ] steps ([[http://klog.icrr.u-tokyo.ac.jp/osl/?r=3358|3558]]). * It's been at its lowest position since the temperature was 25 ºC. We set the keystone to 488 µm and couldn't move it down more ([[http://klog.icrr.u-tokyo.ac.jp/osl/?r=8125|8125]], [[http://klog.icrr.u-tokyo.ac.jp/osl/?r=8645|8645]]). |
|
Line 12: | Line 21: |
=== Bottom filter === * This fishing rod didn't seem to have any problems before but we haven't tried to use it at every temperature condition we've had. * Range:''' '''from''' '''-1000 µm to +1800 µm in the LVDT and from -746,000 to +746,000 steps in the stepper motor ([[http://klog.icrr.u-tokyo.ac.jp/osl/?r=3280|3280]]).What was the temperature that day? == SR2 == === Top filter === Range: ''' [ -1,700,000 , 1,500,000 ]''' === Stardard filter === Range: from -750 µm to 1000 µm in the LVDT and from 300,000 to 1,000,00 steps in the stepper motor ([[http://klog.icrr.u-tokyo.ac.jp/osl/?r=4431|4431]]). === Bottom filter === Range: from -500 µm to 600 µm in the LVDT and from -550,000 to -250,000 ([[http://klog.icrr.u-tokyo.ac.jp/osl/?r=4430|4430]]). === Other related entries === [[http://klog.icrr.u-tokyo.ac.jp/osl/?r=8082|8082]] == SR3 == === Top filter === ([[http://klog.icrr.u-tokyo.ac.jp/osl/?r=7758|7758]]) === Standard Flter === ([[http://p://klog.icrr.u-tokyo.ac.jp/osl/?r=4720|4720]]) === Bottom Filter === ([[http://klog.icrr.u-tokyo.ac.jp/osl/?r=4654|4654]]) === Other related entries === . [[http://klog.icrr.u-tokyo.ac.jp/osl/?r=8658|8658]], [[http://klog.icrr.u-tokyo.ac.jp/osl/?r=8135|8135]]. == SRM == === Top Filter === ([[http://klog.icrr.u-tokyo.ac.jp/osl/?r=7857|7857]]) === Standard Filter === ([[http://klog.icrr.u-tokyo.ac.jp/osl/?r=4721|4721]]) === Bottom Filter === ([[http://klog.icrr.u-tokyo.ac.jp/osl/?r=4721|4721]]) |
Describe KAGRA/Subgroups/VIS/OpsManual/FishingRods here.
This page describes the status of the fishing rods.
Beam splitter
Top filter
Range
- Observations
Standard Filter
- Range
It's been at its lowest position since the temperature was 25 ºC. We set the keystone to 488 µm and couldn't move it down more (8125, 8645).
Bottom filter
- This fishing rod didn't seem to have any problems before but we haven't tried to use it at every temperature condition we've had.
Range: from -1000 µm to +1800 µm in the LVDT and from -746,000 to +746,000 steps in the stepper motor (3280).What was the temperature that day?
SR2
Top filter
Range: [ -1,700,000 , 1,500,000 ]
Stardard filter
Range: from -750 µm to 1000 µm in the LVDT and from 300,000 to 1,000,00 steps in the stepper motor (4431).
Bottom filter
Range: from -500 µm to 600 µm in the LVDT and from -550,000 to -250,000 (4430).
Other related entries
SR3
Top filter
(7758)
Standard Flter
(4720)
Bottom Filter
(4654)
Other related entries
SRM
Top Filter
(7857)
Standard Filter
(4721)
Bottom Filter
(4721)