Line 5: Line 5:
 * [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=5788| JGW-T1605788 Length-Sensing OpLevs for KAGRA]] - writeup by Simon  * [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=5788| JGW-T1605788]] - Length-Sensing !OpLevs for KAGRA, writeup by Simon
 * [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=3946| JGW-T1503946]] - !OpLev, writeup by Ettore Majorana of VIRGO

== Data ==

 * [[KAGRA/Subgroups/AOS/DCQPDList]] - Inventory of QPDs for OLs

== Quadrants ==

{{attachment:QPD Segment Numbering.png| |width = 200}}

== Default OL2EUL Matrix ==

The following matrix is appropriate if the OL beam is bounced off the AR side of the optic. Then, positive pitch of the optic (right-handed around transverse, nose-down) gives a high return beam, more light on SEG3 and SEG4, and positive P. Similarly, positive yaw of the optic (right-handed around vertical, nose-left) gives a return beam offset to the left (looking at the QPD), more light on SEG1 and SEG4, and positive Y.

{{attachment:QPD Default OL2EUL matrix.png| |width = 300}}

== Micrometer Function ==
||Horizontal|| Vertical||Notes||
||Points right||Points down||viewed facing QPD||
||Anticlockwise||Anticlockwise||turn of micrometer knob||
||Retracts tip||Retracts tip|| ||
||Larger numbers||Larger numbers||on micrometer scale||
||Stage moves with tip||Stage moves with body|| ||
||QPD moves left||QPD moves down|| ||
||Spot moves to right quadrants||Spot moves to upper quadrants|| ||
||Simulates -yaw||Simulates +pitch|| ||

KAGRA VIS Operations Manual - Optical Levers

Info

  • JGW-T1605788 - Length-Sensing OpLevs for KAGRA, writeup by Simon

  • JGW-T1503946 - OpLev, writeup by Ettore Majorana of VIRGO

Data

Quadrants

QPD Segment Numbering.png

Default OL2EUL Matrix

The following matrix is appropriate if the OL beam is bounced off the AR side of the optic. Then, positive pitch of the optic (right-handed around transverse, nose-down) gives a high return beam, more light on SEG3 and SEG4, and positive P. Similarly, positive yaw of the optic (right-handed around vertical, nose-left) gives a return beam offset to the left (looking at the QPD), more light on SEG1 and SEG4, and positive Y.

QPD Default OL2EUL matrix.png

Micrometer Function

Horizontal

Vertical

Notes

Points right

Points down

viewed facing QPD

Anticlockwise

Anticlockwise

turn of micrometer knob

Retracts tip

Retracts tip

Larger numbers

Larger numbers

on micrometer scale

Stage moves with tip

Stage moves with body

QPD moves left

QPD moves down

Spot moves to right quadrants

Spot moves to upper quadrants

Simulates -yaw

Simulates +pitch

KAGRA/Subgroups/VIS/OpsManual/OpLev (last edited 2019-12-08 17:14:35 by fabian.arellano)