Differences between revisions 28 and 32 (spanning 4 versions)
Revision 28 as of 2020-03-27 16:32:11
Size: 1588
Editor: KokiOkutomi
Comment:
Revision 32 as of 2020-03-27 16:43:38
Size: 1644
Editor: KokiOkutomi
Comment:
Deletions are marked like this. Additions are marked like this.
Line 8: Line 8:

=== Procedure ===

Line 19: Line 23:
||<#eeeeee> '''Chasses/Devices''' ||<#eeeeee> '''Description''' ||<#eeeeee> '''Links''' || ||<#dddddd> '''Chasses/Devices''' ||<#dddddd> '''Description''' ||<#dddddd> '''Links''' ||
Line 28: Line 32:
 * H. Tariq et al., ''Nucl. Instrum. Methods Phys. Res. A'' '''489''' (1-3), pp. 570-576 (2002) [[https://www.sciencedirect.com/science/article/pii/S0168900202008021|ScienceDirect]]  i. H. Tariq et al., ''Nucl. Instrum. Methods Phys. Res. A'' '''489''' (1-3), pp. 570-576 (2002) [[https://www.sciencedirect.com/science/article/pii/S0168900202008021|ScienceDirect]]

=== Notable klog posts ===

LVDT

Linear Variable Differential Transformer1 is a relative displacement sensor.

Calibration

(Typical calibration plot)

Procedure

Noise

(Typical measurement result)

Setup

(Graphical description)

Peripherals

Chasses/Devices

Description

Links

LVDT Driver

Distributing modulation career to 4 primary coils and demodulating displacement signals from receiver coils.

JGW-D1402826

LVDT-ACT Distributor

[Passive] Rearranging pin assignments from the emitter/receiver collection into the feedthrough port collection

JGW-D1402124

LVDT-ACT Combiner

[Passive] Extented LVDT-ACT distributor with LC filters for sharing receiver/actuator coils.

JGW-D1706069

Implemented location

References

  1. H. Tariq et al., Nucl. Instrum. Methods Phys. Res. A 489 (1-3), pp. 570-576 (2002) ScienceDirect

Notable klog posts

See also

  1. Sometimes referred to also as Transducer which is more suitable in terms of electronics. (1)

KAGRA/Subgroups/VIS/Sensors/LVDT (last edited 2020-03-27 16:43:38 by KokiOkutomi)