Differences between revisions 1 and 6 (spanning 5 versions)
Revision 1 as of 2019-12-22 17:07:24
Size: 280
Comment:
Revision 6 as of 2019-12-22 17:36:35
Size: 1878
Comment:
Deletions are marked like this. Additions are marked like this.
Line 1: Line 1:
== Measurement information ==
Line 9: Line 11:
== /users/VIS/TypeA/ ==


==== Striptool configuration files ====
  * /users/VIS/TypeA/${suspension}/monitor_config/stp_files
    * where suspension=ETMX, ETMY, ITMX or ITMY.
  
==== dv configuration files ====
 * /users/VIS/TypeA/${suspension}/monitor_config/dv_files
    * where suspension=ETMX, ETMY, ITMX or ITMY.

----

== /users/VIS/TypeA/general/ ==
=== axis_check/ ===
  * 20190928/
   * The time series when each IP-stage was steered in DC.

  * 20191009/
    * measurement files in .xml and the scripts to get the angle offset and the figures.

=== bruco/ ===
  * test files to run the bruco


=== calib/ ===
  * Measurement files for the length-oplev calibration with hte arm cavities.


=== for_summary/ ===
  * Some of the scripts and the output figures used in PhD thesis by Y. Fujii.


=== implemented_filter_info/ ===
  * The filter information which was used at the date which the dir_name shows, especially at ETMX.


=== LogNotes/ ===
  * To be added



=== measurement_for_modeling/${suspension}/ ===
  * This folder contains the measured transfer function information in terms of .txt and .pdf file.
  * the fitted zpk information is summarized in '''''fitting-results.txt'''''


=== monitor_config/ ===
  * diaggui files which monitors each stage spectra of each suspension is stored.
    * '''''TM_monitor.xml''''' would be useful.


=== qfactor_measurement/ ===
 * All the measurement files used for the decay-time measurement, which was done with ETMX suspension is stored.





Measurement information

  • The information of dir is (will be) listed in this page.
    • This page basically focuses on:
      • /users/VIS/TypeA/
      • /users/VISsvn/TypeA${part}/
      • where part=tower or part=payload
    • Also this focuses on the measurements by Y. Fujii from 2018 to 2019.


/users/VIS/TypeA/

Striptool configuration files

  • /users/VIS/TypeA/${suspension}/monitor_config/stp_files
    • where suspension=ETMX, ETMY, ITMX or ITMY.

dv configuration files

  • /users/VIS/TypeA/${suspension}/monitor_config/dv_files
    • where suspension=ETMX, ETMY, ITMX or ITMY.


/users/VIS/TypeA/general/

axis_check/

  • 20190928/
    • The time series when each IP-stage was steered in DC.
  • 20191009/
    • measurement files in .xml and the scripts to get the angle offset and the figures.

bruco/

  • test files to run the bruco

calib/

  • Measurement files for the length-oplev calibration with hte arm cavities.

for_summary/

  • Some of the scripts and the output figures used in PhD thesis by Y. Fujii.

implemented_filter_info/

  • The filter information which was used at the date which the dir_name shows, especially at ETMX.

LogNotes/

  • To be added

measurement_for_modeling/${suspension}/

  • This folder contains the measured transfer function information in terms of .txt and .pdf file.
  • the fitted zpk information is summarized in fitting-results.txt

monitor_config/

  • diaggui files which monitors each stage spectra of each suspension is stored.
    • TM_monitor.xml would be useful.

qfactor_measurement/

  • All the measurement files used for the decay-time measurement, which was done with ETMX suspension is stored.

KAGRA/Subgroups/VIS/TypeA/WorkingLog/dir_information (last edited 2019-12-22 17:44:34 by YoshinoriFujii)