Measurement information

  • The information of dir is (will be) listed in this page.
    • This page basically focuses on:
      • /users/VIS/TypeA/
      • /users/VISsvn/TypeA${part}/
      • where part=tower or part=payload
    • Also this focuses on the measurements by Y. Fujii from 2018 to 2019.


/users/VIS/TypeA/

Striptool configuration files

  • /users/VIS/TypeA/${suspension}/monitor_config/stp_files
    • where suspension=ETMX, ETMY, ITMX or ITMY.

dv configuration files

  • /users/VIS/TypeA/${suspension}/monitor_config/dv_files
    • where suspension=ETMX, ETMY, ITMX or ITMY.


/users/VIS/TypeA/general/

axis_check/

  • 20190928/
    • The time series when each IP-stage was steered in DC.
  • 20191009/
    • measurement files in .xml and the scripts to get the angle offset and the figures.

bruco/

  • test files to run the bruco

calib/

  • Measurement files for the length-oplev calibration with hte arm cavities.

for_summary/

  • Some of the scripts and the output figures used in PhD thesis by Y. Fujii.

implemented_filter_info/

  • The filter information which was used at the date which the dir_name shows, especially at ETMX.

LogNotes/

  • To be added

measurement_for_modeling/${suspension}/

  • This folder contains the measured transfer function information in terms of .txt and .pdf file.
  • the fitted zpk information is summarized in fitting-results.txt

monitor_config/

  • diaggui files which monitors each stage spectra of each suspension is stored.
    • TM_monitor.xml would be useful.

qfactor_measurement/

  • All the measurement files used for the decay-time measurement, which was done with ETMX suspension is stored.

rms_suppression/

toDARM/

utility/

Xarm_measurement/

  • The transfer functions of ETMX and ITMX measured with X-arm cavity in Dec. 2018 and Jan 2019.
  • This folder has the measurement results in .txt and .pdf. The measurement files in .xml is in other dirs (see the plottf.m, for example.)

  • Super messy and not much meaningful for you since the suspensions were extracted from the chamber once after this measurement and were re-installed. I.e, these measurement have to be done again and have t be updated.