Participants: | Participants:Takahashi, Tatsumi, Okutomi, Joris, Aso, Fabian, Raffaele, Ishizaki, Mark, Fujii, Shoda, Akutsu, Shoda |
Line 10: | Line 10: |
* An OSEM flag on the mirror detached (right-bottom one seen from the AR side) * It was touching the OSEM when RM was slid in. * One of the 2nd wire breakers detached * Found a crack in one of the 1st wire breakers * The crack is in the middle of the prism. Not in the V-grooves. * Checked the spare mirror used for the test hanging: found a crack too (in the middle) |
|
Line 12: | Line 18: |
* Keep using them has a risk of further crack development * Replacing will take at least a few weeks: a large impact on the schedule * Will ask SEO (or EO) for executive judgement |
|
Line 13: | Line 22: |
* Do we need to remove the residual glue on the mirror ? * If so, where to remove it ? |
* Do we need to remove the residual glue on the mirror ?-> Yes |
Line 16: | Line 24: |
* Mirror transportation arrangement |
* We need to use acetone for the removal of the residual glue * We will perform the work in an ATC clean room. Will use only a small amount of acetone following the ATC rule. * Tatsumi-san is available to do the above task in Mitaka * Mirror transportation * Ishizaki-san will transport the mirror * Ideally, using the official vhiecle of the NAOJ is better but the vhiecle is already booked this time. |
PR3 Meeting on 2016/1/26
2015/1/26 13:30 -
Kamioka TV conference room + SeeVogh
Participants:Takahashi, Tatsumi, Okutomi, Joris, Aso, Fabian, Raffaele, Ishizaki, Mark, Fujii, Shoda, Akutsu, Shoda
Agenda
- What happened (Shoda)
- An OSEM flag on the mirror detached (right-bottom one seen from the AR side)
- It was touching the OSEM when RM was slid in.
- One of the 2nd wire breakers detached
- Found a crack in one of the 1st wire breakers
- The crack is in the middle of the prism. Not in the V-grooves.
- Checked the spare mirror used for the test hanging: found a crack too (in the middle)
- An OSEM flag on the mirror detached (right-bottom one seen from the AR side)
- What to do with the sapphire prism
- Replace or keep using them ?
- Keep using them has a risk of further crack development
- Replacing will take at least a few weeks: a large impact on the schedule
- Will ask SEO (or EO) for executive judgement
- What to do with the flag base and 2nd wire breaker
Do we need to remove the residual glue on the mirror ?-> Yes
- Where to do the gluing work ?
- We need to use acetone for the removal of the residual glue
- We will perform the work in an ATC clean room. Will use only a small amount of acetone following the ATC rule.
- Tatsumi-san is available to do the above task in Mitaka
- Mirror transportation
- Ishizaki-san will transport the mirror
- Ideally, using the official vhiecle of the NAOJ is better but the vhiecle is already booked this time.