Line 2: Line 2:
2016/2/4 15:00 - 2016/2/4 15:00 -

Participants: Takahashi, Aso, Mark, Shoda, Raffaele, Akutsu, Okutomi, Fujii, Sekiguchi
Line 6: Line 8:
  * https://db.tt/vg6TQYYa
  * https://db.tt/xKopUuUz
Line 7: Line 11:
  * Identify missing parts
  * Improvement for bKAGRA
  * Other suspensions
  * We went through the cables for PR3.
   * Overview diagram was drawn on a white board (picture)
    * Blue double circles indicates cables to be replaced from the test hanging (because of wrong pin-out).
    * Red check marks mean we checked the corresponding cable
   * Missing parts -> nothing
   * Connection between an LVDT driver and an ADC required a gender changer. Against the general policy of KAGRA electronics, the output connector of the LVDT driver is male (output should be female in the policy). Therefore, a gender changer was necessary. We should add a gender changer at the output of the LVDT driver.
  * Future improvement
   * We need an overview schematic like the one drawn in the meeting with links to more detailed documents.
   * From the schematic, we should generate a table of necessary cables
   * We should use this table to check if we have all the necessary cables

iKAGRA VIS electronics review

2016/2/4 15:00 -

Participants: Takahashi, Aso, Mark, Shoda, Raffaele, Akutsu, Okutomi, Fujii, Sekiguchi

Agenda

  • PR3 electronics diagram (Mark)
  • Discussion
    • We went through the cables for PR3.
      • Overview diagram was drawn on a white board (picture)
        • Blue double circles indicates cables to be replaced from the test hanging (because of wrong pin-out).
        • Red check marks mean we checked the corresponding cable
      • Missing parts -> nothing

      • Connection between an LVDT driver and an ADC required a gender changer. Against the general policy of KAGRA electronics, the output connector of the LVDT driver is male (output should be female in the policy). Therefore, a gender changer was necessary. We should add a gender changer at the output of the LVDT driver.
    • Future improvement
      • We need an overview schematic like the one drawn in the meeting with links to more detailed documents.
      • From the schematic, we should generate a table of necessary cables
      • We should use this table to check if we have all the necessary cables

KAGRA/Subgroups/VIS/VISMinutes20160204 (last edited 2016-02-05 10:10:14 by YoichiAso)