Differences between revisions 11 and 35 (spanning 24 versions)
Revision 11 as of 2020-04-17 09:34:41
Size: 1365
Editor: AyakaShoda
Comment:
Revision 35 as of 2020-04-17 12:40:18
Size: 3478
Editor: KousekiMiyo
Comment:
Deletions are marked like this. Additions are marked like this.
Line 2: Line 2:
2020/4/17 14:00 -  2020/4/17 14:00 -
Line 6: Line 6:
Participants:  Participants:
Line 15: Line 15:
=== General ===
(Miyo) I'm gathering information about the hardware part. (e.g. cabling, calibration of sensors and actuators.)
 * [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=11597|JGW-T2011597]] Calibration factors of LVDTs .
  * '''Purpose''' : To check the consistency in the klog information.
  * '''Status''' : Please check about Type-A and Type-Bp. ([[https://github.com/gw-vis/kagra-vis/issues/9|Issues list]]) -> __I will make a private meeting with Okutomi-san and Fuji-kun on Saturday to discuss__
  * [[https://github.com/gw-vis/kagra-vis/issues/7|Type-B is OK]]. Thank you fabian! :)
 * [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=11573|JGW-D2011573]] Cabling diagram which includes connections among AEL circuits and pin assignment at the feed-through.
  * '''Purpose''' : To make a consensus about the cabling with AEL and CRYO group for O4.
  * '''Status''' Need information about the pin assignment for all suspensions -> __Sato-san? and Shoda-san?__
Line 17: Line 27:
Line 18: Line 29:
 * In the context of writing a paper I gathered information about OSEMs and LVDTs and uploaded a document at : [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=11612|JGW-T2011612]], which I will be updating.Currently the content is
  * Linear ranges of 24 OSEMs and
  * Sensitivity of the six SRM OSEMS.
 * I gave feedback to Miyo-kun about LVDTs: all the current calibration factors in medm screens are consistent with klog reports. Just as a reminder:
  * The polarity of LVDTs is set in hardware: increase in LVDT output always means upwards motion or positive yaw in the IPs. Therefore, calibration factors in medm screens should always be positive.
  * An exception seems to be BS IP H2 LVDT, whose medm screen I have to check for a minus sign somewhere.
  * The offsets in medm screens correspond to the nominal places of keystones per the 3D-CAD, not the mid-point of the linear range.
Line 23: Line 42:
 * Papers (Type-B: Fabian, Type-A:?)  * Papers (Type-B: Fabian, Type-A: Lucia?)
Line 25: Line 44:
Line 27: Line 47:
Line 28: Line 49:
 * Had a VIS control strategy meeting [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=11557|documents]]  * For a summary of the current status of inertial damping in Type-B suspensions see the appendix (p14 onwards) in this [[https://1drv.ms/b/s!AoQaV1tdsEcUgc5MtkkqJv5fcCYBrw?e=TXSzu0|presentation]] shown the Commissioning Meeting on the 27th of September 2019.
Line 32: Line 54:

Agenda/Minutes of the VIS Meeting on 2020/4/17

2020/4/17 14:00 -

Zoom Meeting

Participants:

VIS Commissioning Task List

Task list towards O4

Schedule afetr O3

Progress report

General

(Miyo) I'm gathering information about the hardware part. (e.g. cabling, calibration of sensors and actuators.)

  • JGW-T2011597 Calibration factors of LVDTs .

    • Purpose : To check the consistency in the klog information.

    • Status : Please check about Type-A and Type-Bp. (Issues list) -> I will make a private meeting with Okutomi-san and Fuji-kun on Saturday to discuss

    • Type-B is OK. Thank you fabian! :)

  • JGW-D2011573 Cabling diagram which includes connections among AEL circuits and pin assignment at the feed-through.

    • Purpose : To make a consensus about the cabling with AEL and CRYO group for O4.

    • Status Need information about the pin assignment for all suspensions -> Sato-san? and Shoda-san?

Type-A

Type B

  • In the context of writing a paper I gathered information about OSEMs and LVDTs and uploaded a document at : JGW-T2011612, which I will be updating.Currently the content is

    • Linear ranges of 24 OSEMs and
    • Sensitivity of the six SRM OSEMS.
  • I gave feedback to Miyo-kun about LVDTs: all the current calibration factors in medm screens are consistent with klog reports. Just as a reminder:
    • The polarity of LVDTs is set in hardware: increase in LVDT output always means upwards motion or positive yaw in the IPs. Therefore, calibration factors in medm screens should always be positive.
    • An exception seems to be BS IP H2 LVDT, whose medm screen I have to check for a minus sign somewhere.
    • The offsets in medm screens correspond to the nominal places of keystones per the 3D-CAD, not the mid-point of the linear range.

Type-Bp

Type-C

Electronics

Post O3 (4/21~)

  • Request

  • Papers (Type-B: Fabian, Type-A: Lucia?)
  • Operation mode at the shutdown of KAGRA

Towards O3c

Controls

  • For a summary of the current status of inertial damping in Type-B suspensions see the appendix (p14 onwards) in this presentation shown the Commissioning Meeting on the 27th of September 2019.

Safety

Discussion

Travel Plans

Next meeting

On 2020/4/24(Fri)

KAGRA/Subgroups/VIS/VISMinutes20200417 (last edited 2020-04-18 10:45:23 by RyutaroTakahashi)