Size: 1168
Comment:
|
Size: 1860
Comment:
|
Deletions are marked like this. | Additions are marked like this. |
Line 17: | Line 17: |
* Type-Bp: Inter-calibration for the BF damper in PR3. | * Type-Bp: Inter-calibration for the BF damper in PR3. Monitoring of PRM during the vent. |
Line 38: | Line 38: |
* Replaced the SG board for the LVDT drivers with a new board in IY. The oscillator signal became stable. The old board seems to have a break in the circuit. |
|
Line 39: | Line 41: |
* For the BS, Terrence and I have been calculating the IP-L sensor correction and blending filters. Terrence had new ideas for updating the calculation of the filters, and it was worth trying. I aim to test the results next week. | |
Line 40: | Line 43: |
* For PR3, I added the inter-calibration factor and the BF Damper sensor correction filter. The sensor correction is enabled when the suspension goes through ENGAGE_STRONGDAMP state. |
|
Line 46: | Line 52: |
* Type-B/Bp: Sensor correction. | * Type-B/Bp: BS sensor correction and blending. |
Line 57: | Line 63: |
The week from 3/13 * Aso: 3/13-14 * Sato: 3/15-16 |
Contents
Agenda/Minutes
CRY+VIS Interface Meeting
Date: 2023/3/3 13:00-
Participants:
Status
- Type-A: Replacement of the SG board for the LVDTs in IY. Offload of the BF GAS in IY.
- Type-B:
- Type-Bp: Inter-calibration for the BF damper in PR3. Monitoring of PRM during the vent.
- Type-C:
Other items
- Oplev:
- ACC:
- Commissioning:
- Vacuum system: Switching from the TMPs to the SIPs.
- Heater control: Adjustment in IY.
- TMS: Covering in TMSY on 2-3 March.
Discussion
VIS Meeting
Date: 2023/3/3 13:30-
Participants:
Summary Report
Type-A
- Replaced the SG board for the LVDT drivers with a new board in IY. The oscillator signal became stable. The old board seems to have a break in the circuit.
Type-B
- For the BS, Terrence and I have been calculating the IP-L sensor correction and blending filters. Terrence had new ideas for updating the calculation of the filters, and it was worth trying. I aim to test the results next week.
Type-Bp
- For PR3, I added the inter-calibration factor and the BF Damper sensor correction filter. The sensor correction is enabled when the suspension goes through ENGAGE_STRONGDAMP state.
Type-C
Electronics
Control
Schedule
- Type-A: IP control with ACCs.
- Type-B/Bp: BS sensor correction and blending.
- Type-C:
Safety
Discussion
Travel Plans
(Date in Kamioka)
The week from 3/6
The week from 3/13
- Aso: 3/13-14
- Sato: 3/15-16
Next meeting
- 2023/3/10(FRI) 13:30-