Differences between revisions 10 and 11
Revision 10 as of 2011-01-02 10:31:13
Size: 1440
Comment:
Revision 11 as of 2011-02-15 09:59:59
Size: 1403
Comment:
Deletions are marked like this. Additions are marked like this.
Line 10: Line 10:
||Name||Vertex||IX||IY||EX||EY||MX||MY||control room||mine||outside(building)||Others(num., place)|| ||Name||Laser||Center||IX||IY||EX||EY||MX||MY||control room||mine||outside(building)||Others(num., place)||
Line 12: Line 12:
||Room temperature||1 + 1(laser room)||1||1||1||1||1||1|| || ||1|| ||
||Optical table temperature||4(laser, MC, REFL, AS)||1||1||1||1|| || || || || || ||
||Seismometer||1x3axis||1x3axis||1x3axis||1x3axis||1x3axis||1x3axis||1x3axis|| || ||1x3axis|| ||
||Tilt meter||1||1||1||1||1|| || || || || || ||
||Humidity||1 + 1(laser room)|| || ||1||1||1||1|| || || || ||
||Particle||1 + 1(laser room)||1||1||1||1||1?||1?|| ||1?|| || ||
||Microphone||3 +1(laser room) +5(each PD table)||1||1||1||1|| || || ||1|| || ||
||Air Pressure||1||1||1||1||1||1?||1?|| ||1?|| || ||
||Magnetic field(3 axes)||1||1||1||1||1||1?||1?|| ||1?|| || ||
||Room temperature||1||1||1||1||1||1||1||1|| || ||1|| ||
||Optical table temperature||1||3(MC, REFL, AS)||1||1||1||1|| || || || || || ||
||Seismometer|| ||1x3axis||1x3axis||1x3axis||1x3axis||1x3axis||1x3axis||1x3axis|| || ||1x3axis|| ||
||Tilt meter|| ||1||1||1||1||1|| || || || || || ||
||Humidity||1||1|| || ||1||1||1||1|| || || || ||
||Particle||1||1||1||1||1||1||1?||1?|| ||1?|| || ||
||Microphone||1||3+5(each PD table)||1||1||1||1|| || || ||1|| || ||
||Air Pressure||1||1||1||1||1||1||1?||1?|| ||1?|| || ||
||Magnetic field(3 axes)|| ||1||1||1||1||1||1?||1?|| ||1?|| || ||

Physical Environmental Monitoring Systm

Reference


PEM channel list

Name

Laser

Center

IX

IY

EX

EY

MX

MY

control room

mine

outside(building)

Others(num., place)

Room temperature

1

1

1

1

1

1

1

1

1

Optical table temperature

1

3(MC, REFL, AS)

1

1

1

1

Seismometer

1x3axis

1x3axis

1x3axis

1x3axis

1x3axis

1x3axis

1x3axis

1x3axis

Tilt meter

1

1

1

1

1

Humidity

1

1

1

1

1

1

Particle

1

1

1

1

1

1

1?

1?

1?

Microphone

1

3+5(each PD table)

1

1

1

1

1

Air Pressure

1

1

1

1

1

1

1?

1?

1?

Magnetic field(3 axes)

1

1

1

1

1

1?

1?

1?

  • IX:Room for ITMX, EX:Room for ETMX, MX:Room for middle of X arm, the same as Y

Name

number

Low temperature monitor for suspensions

96(3ADCs) x 4sus=384

  • 温度計の測定精度から16ビット以上を希望
  • 温度計測定法から各入力チャンネルはコモン共通のシングルエンド入力では駄目で、チャンネル間が独立した絶縁入力が必要