Differences between revisions 11 and 45 (spanning 34 versions)
Revision 11 as of 2011-02-15 09:59:59
Size: 1403
Comment:
Revision 45 as of 2012-06-06 18:31:03
Size: 3035
Comment:
Deletions are marked like this. Additions are marked like this.
Line 1: Line 1:
## page was renamed from LCGT/PEM
Line 8: Line 9:
=== PEM channel list === === PEM sensors list ===
Line 10: Line 11:
||Name||Laser||Center||IX||IY||EX||EY||MX||MY||control room||mine||outside(building)||Others(num., place)||
|| || || || || || || || || || || || ||
||Room temperature||1||1||1||1||1||1||1||1|| || ||1|| ||
||Optical table temperature||1||3(MC, REFL, AS)||1||1||1||1|| || || || || || ||
||Seismometer|| ||1x3axis||1x3axis||1x3axis||1x3axis||1x3axis||1x3axis||1x3axis|| || ||1x3axis|| ||
||Tilt meter|| ||1||1||1||1||1|| || || || || || ||
||Humidity||1||1|| || ||1||1||1||1|| || || || ||
||Particle||1||1||1||1||1||1||1?||1?|| ||1?|| || ||
||Microphone||1||3+5(each PD table)||1||1||1||1|| || || ||1|| || ||
||Air Pressure||1||1||1||1||1||1||1?||1?|| ||1?|| || ||
||Magnetic field(3 axes)|| ||1||1||1||1||1||1?||1?|| ||1?|| || ||
==== GW IFO ====
||Name ||Laser||Center||IX||IY||EX||EY||TX||TY||control room||mine||outside||Total||
|| || || || || || || || || || || || || ||
||Thermo. L ||1+1(table)||3+6(table)||1||1||1||1|| || ||1||1||1|| ||
||Thermo. H || || || || || || || || || || || || ||
||Hygrometer ||1||1||1||1||1||1|| || ||1|| || || ||
||Barometer ||1||1||1||1||1||1|| || || || ||1|| ||
||Accel. L ||1||1|| || || || || || || || || || ||
||Accel. H || || || || || || || || || || || || ||
||Accel. 3D || ||1||1||1||1||1|| || || || ||1|| ||
||Particle ||1||1||1||1||1||1|| || || || || || ||
||Seismometer || || || || || || || || || || || || ||
||Microphone ||1+1(table)||3+ 6(table)||1||1||1||1|| || || ||1|| || ||
||Tilt meter || ||1||1||1||1||1|| || || || || || ||
||Magnetic field (3axes)|| ||1||1||1||1||1|| || || || || || ||
Line 22: Line 27:
 * IX:Room for ITMX, EX:Room for ETMX, MX:Room for middle of X arm, the same as Y

||Name||number||
||Name||Quantity||
Line 28: Line 31:

==== Geo IFO ====
||Name ||Laser||Center||IX||IY||EX||EY||TX||TY||control room||mine||outside||Total||
|| || || || || || || || || || || || || ||
||Thermo. L ||2|| ||1||1||1||1|| || || || || || ||
||Thermo. H || ||4|| || ||1||1||5||5|| || || || ||
||Hygrometer || ||4|| || ||1||1||5||5|| || || || ||
||Barometer || ||4|| || || || ||1||1|| || || || ||
||Accel. L ||2|| ||1||1||1||1|| || || || || || ||
||Accel. H || || || || || || || || || || || || ||
||Accel. 3D || ||4|| || || || || || || || || || ||
||Particle || ||2|| || || || || || || || || || ||
||Seismometer || || || || || || ||1||1|| || || || ||
||Microphone || || || || || || || || || || || || ||
||Tilt meter || || || || || || || || || || || || ||
||Magnetic field (3axes)|| || || || || || || || || || || || ||

 * IX:Room for ITMX, EX:Room for ETMX, TX:Tunnel of X arm, the same as Y
 * Thermo. L : Low resolution (~0.1K) thermometer (e.g. IC sensors monitoring instrument temp.)
 * Thermo. H : High resolution (~0.001K) thermometer (e.g. monitoring room / tunnel temp.)
 * Accel. L : Acceleration pick up (e.g. vibration monitor)
 * Accel. H : 1-dim. accelerometer (e.g. acceleration to be used for quantitative analyses)
 * Accel. 3D : 3-dim. accelerometer for 3-dim. analyses.

Physical Environmental Monitoring Systm

Reference


PEM sensors list

GW IFO

Name

Laser

Center

IX

IY

EX

EY

TX

TY

control room

mine

outside

Total

Thermo. L

1+1(table)

3+6(table)

1

1

1

1

1

1

1

Thermo. H

Hygrometer

1

1

1

1

1

1

1

Barometer

1

1

1

1

1

1

1

Accel. L

1

1

Accel. H

Accel. 3D

1

1

1

1

1

1

Particle

1

1

1

1

1

1

Seismometer

Microphone

1+1(table)

3+ 6(table)

1

1

1

1

1

Tilt meter

1

1

1

1

1

Magnetic field (3axes)

1

1

1

1

1

Name

Quantity

Low temperature monitor for suspensions

96(3ADCs) x 4sus=384

Geo IFO

Name

Laser

Center

IX

IY

EX

EY

TX

TY

control room

mine

outside

Total

Thermo. L

2

1

1

1

1

Thermo. H

4

1

1

5

5

Hygrometer

4

1

1

5

5

Barometer

4

1

1

Accel. L

2

1

1

1

1

Accel. H

Accel. 3D

4

Particle

2

Seismometer

1

1

Microphone

Tilt meter

Magnetic field (3axes)

  • IX:Room for ITMX, EX:Room for ETMX, TX:Tunnel of X arm, the same as Y

  • Thermo. L : Low resolution (~0.1K) thermometer (e.g. IC sensors monitoring instrument temp.)
  • Thermo. H : High resolution (~0.001K) thermometer (e.g. monitoring room / tunnel temp.)
  • Accel. L : Acceleration pick up (e.g. vibration monitor)
  • Accel. H : 1-dim. accelerometer (e.g. acceleration to be used for quantitative analyses)
  • Accel. 3D : 3-dim. accelerometer for 3-dim. analyses.
  • 温度計の測定精度から16ビット以上を希望
  • 温度計測定法から各入力チャンネルはコモン共通のシングルエンド入力では駄目で、チャンネル間が独立した絶縁入力が必要

KAGRA/Subsystems/PEM (last edited 2012-06-06 18:31:03 by OsamuMiyakawa)