Size: 969
Comment:
|
Size: 2618
Comment:
|
Deletions are marked like this. | Additions are marked like this. |
Line 10: | Line 10: |
||Name||Vertex||IX||IY||EX||EY||MX||MY||control room||mine||outside(building)||Others(num., place)|| || || || || || || || || || || || || || ||Room Temperature||1 + 1(laser room)||1||1||1||1||1||1|| || ||1|| || ||Seismometer||1x3axis||1x3axis||1x3axis||1x3axis||1x3axis||1x3axis||1x3axis|| || ||1x3axis|| || ||Tilt meter||1||1||1||1||1|| || || || || || || ||Humid||1 + 1(laser room)|| || ||1||1||1||1|| || || || || ||Particle||1||1||1||1||1||1?||1?|| ||1?|| || || ||Microphone||3 +1(laser room) +5(each PD table)||1||1||1||1|| || || ||1|| || || |
==== GW IFO ==== ||Name ||Laser||Center||IX||IY||EX||EY||TX||TY||control room||mine||outside||Total|| || || || || || || || || || || || || || || ||Thermometer L ||1+1(table)|| ||1||1||1||1||1||1||1||1||1|| || ||Thermometer H || ||1+3(table)|| || || || || || || || ||1|| || ||Hygrometer ||1||1|| || ||1||1||1||1|| || || || || ||Barometer ||1||1||1||1||1||1||1?||1?|| ||1?|| || || ||Particle ||1||1||1||1||1||1|| || || || || || || ||Accelerometer L ||1||1|| || || || || || || || || || || ||Accelerometer H || || || || || || || || || || || || || ||Accelerometer (3axis) || ||1||1||1||1||1|| || || || ||1|| || ||Seismometer || || || || || || ||1||1|| || || || || ||Tilt meter || ||1||1||1||1||1|| || || || || || || ||Microphone ||1||3+ 5(PD tables)||1||1||1||1|| || || ||1|| || || ||Magnetic field (3axes)|| ||1||1||1||1||1|| || || || || || || |
Line 19: | Line 26: |
IX:Room for ITMX, EX:Room for ETMX, MX:Room for middle of X arm, the same as Y | ==== Geo IFO ==== ||Name ||Laser||Center||IX||IY||EX||EY||TX||TY||control room||mine||outside||Total|| || || || || || || || || || || || || || || ||Thermometer L ||2|| ||1||1||1||1|| || || || || || || ||Thermometer H || ||4|| || ||1||1||5||5|| || || || || ||Hygrometer ||1||1|| || ||1||1||1||1|| || || || || ||Barometer ||1||1||1||1||1||1||1?||1?|| ||1?|| || || ||Particle ||1||1||1||1||1||1|| || || || || || || ||Accelerometer L ||1||1|| || || || || || || || || || || ||Accelerometer H || || || || || || || || || || || || || ||Accelerometer (3axis) || ||1||1||1||1||1|| || || || ||1|| || ||Seismometer || || || || || || ||1||1|| || || || || ||Tilt meter || ||1||1||1||1||1|| || || || || || || ||Microphone ||1||3+ 5(PD tables)||1||1||1||1|| || || ||1|| || || ||Magnetic field (3axes)|| ||1||1||1||1||1|| || || || || || || * IX:Room for ITMX, EX:Room for ETMX, TX:Tunnel of X arm, the same as Y |
Line 23: | Line 46: |
||Low temperature monitor for suspensions||150 x 4sus|| | ||Low temperature monitor for suspensions||96(3ADCs) x 4sus=384|| * 温度計の測定精度から16ビット以上を希望 * 温度計測定法から各入力チャンネルはコモン共通のシングルエンド入力では駄目で、チャンネル間が独立した絶縁入力が必要 |
Physical Environmental Monitoring Systm
Reference
PEM channel list
GW IFO
Name |
Laser |
Center |
IX |
IY |
EX |
EY |
TX |
TY |
control room |
mine |
outside |
Total |
|
|
|
|
|
|
|
|
|
|
|
|
|
Thermometer L |
1+1(table) |
|
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
|
Thermometer H |
|
1+3(table) |
|
|
|
|
|
|
|
|
1 |
|
Hygrometer |
1 |
1 |
|
|
1 |
1 |
1 |
1 |
|
|
|
|
Barometer |
1 |
1 |
1 |
1 |
1 |
1 |
1? |
1? |
|
1? |
|
|
Particle |
1 |
1 |
1 |
1 |
1 |
1 |
|
|
|
|
|
|
Accelerometer L |
1 |
1 |
|
|
|
|
|
|
|
|
|
|
Accelerometer H |
|
|
|
|
|
|
|
|
|
|
|
|
Accelerometer (3axis) |
|
1 |
1 |
1 |
1 |
1 |
|
|
|
|
1 |
|
Seismometer |
|
|
|
|
|
|
1 |
1 |
|
|
|
|
Tilt meter |
|
1 |
1 |
1 |
1 |
1 |
|
|
|
|
|
|
Microphone |
1 |
3+ 5(PD tables) |
1 |
1 |
1 |
1 |
|
|
|
1 |
|
|
Magnetic field (3axes) |
|
1 |
1 |
1 |
1 |
1 |
|
|
|
|
|
|
Geo IFO
Name |
Laser |
Center |
IX |
IY |
EX |
EY |
TX |
TY |
control room |
mine |
outside |
Total |
|
|
|
|
|
|
|
|
|
|
|
|
|
Thermometer L |
2 |
|
1 |
1 |
1 |
1 |
|
|
|
|
|
|
Thermometer H |
|
4 |
|
|
1 |
1 |
5 |
5 |
|
|
|
|
Hygrometer |
1 |
1 |
|
|
1 |
1 |
1 |
1 |
|
|
|
|
Barometer |
1 |
1 |
1 |
1 |
1 |
1 |
1? |
1? |
|
1? |
|
|
Particle |
1 |
1 |
1 |
1 |
1 |
1 |
|
|
|
|
|
|
Accelerometer L |
1 |
1 |
|
|
|
|
|
|
|
|
|
|
Accelerometer H |
|
|
|
|
|
|
|
|
|
|
|
|
Accelerometer (3axis) |
|
1 |
1 |
1 |
1 |
1 |
|
|
|
|
1 |
|
Seismometer |
|
|
|
|
|
|
1 |
1 |
|
|
|
|
Tilt meter |
|
1 |
1 |
1 |
1 |
1 |
|
|
|
|
|
|
Microphone |
1 |
3+ 5(PD tables) |
1 |
1 |
1 |
1 |
|
|
|
1 |
|
|
Magnetic field (3axes) |
|
1 |
1 |
1 |
1 |
1 |
|
|
|
|
|
|
IX:Room for ITMX, EX:Room for ETMX, TX:Tunnel of X arm, the same as Y
Name |
number |
|
|
Low temperature monitor for suspensions |
96(3ADCs) x 4sus=384 |
- 温度計の測定精度から16ビット以上を希望
- 温度計測定法から各入力チャンネルはコモン共通のシングルエンド入力では駄目で、チャンネル間が独立した絶縁入力が必要