Differences between revisions 40 and 41
Revision 40 as of 2011-02-15 13:03:41
Size: 2609
Comment:
Revision 41 as of 2011-02-15 13:19:47
Size: 2764
Comment:
Deletions are marked like this. Additions are marked like this.
Line 13: Line 13:
||Thermometer L ||1+1(table)||3+6(table)||1||1||1||1|| || ||1||1||1|| ||
||Thermometer H || || || || || || || || || || || || ||
||Thermo. L ||1+1(table)||3+6(table)||1||1||1||1|| || ||1||1||1|| ||
||Thermo. H || || || || || || || || || || || || ||
Line 17: Line 17:
||Accelerometer L ||1||1|| || || || || || || || || || ||
||Accelerometer H || || || || || || || || || || || || ||
||Accelerometer (3axis) || ||1||1||1||1||1|| || || || ||1|| ||
||Accel. L        ||1||1|| || || || || || || || || || ||
||Accel. H        || || || || || || || || || || || || ||
||Accel. 3D || ||1||1||1||1||1|| || || || ||1|| ||
Line 34: Line 34:
||Thermometer L ||2|| ||1||1||1||1|| || || || || || ||
||Thermometer H || ||4|| || ||1||1||5||5|| || || || ||
||Thermo. L     ||2|| ||1||1||1||1|| || || || || || ||
||Thermo. H     || ||4|| || ||1||1||5||5|| || || || ||
Line 38: Line 38:
||Accelerometer L ||2|| ||1||1||1||1|| || || || || || ||
||Accelerometer H || || || || || || || || || || || || ||
||Accelerometer (3axis) || ||4|| || || || || || || || || || ||
||Accel. L        ||2|| ||1||1||1||1|| || || || || || ||
||Accel. H        || || || || || || || || || || || || ||
||Accel. 3D || ||4|| || || || || || || || || || ||
Line 48: Line 48:


 * 温度計の測定精度から16ビット以上を希望
 * 温度計測定法から各入力チャンネルはコモン共通のシングルエンド入力では駄目で、チャンネル間が独立した絶縁入力が必要
 * Thermo. L : Low resolution (~0.1K) thermometer (e.g. IC sensors monitoring instrument temp.)
 * Thermo. H : High resolution (~0.001K) thermometer (e.g. monitoring room / tunnel temp.)
 * Accel. L : Acceleration pick up (e.g. vibration monitor)
 * Accel. H : 1-dim. accelerometer (e.g. acceleration to be used for quantitative analyses)
 * Accel. 3D : 3-dim. accelerometer for 3-dim. analyses.

Physical Environmental Monitoring Systm

Reference


PEM channel list

GW IFO

Name

Laser

Center

IX

IY

EX

EY

TX

TY

control room

mine

outside

Total

Thermo. L

1+1(table)

3+6(table)

1

1

1

1

1

1

1

Thermo. H

Hygrometer

1

1

1

1

1

1

Barometer

1

1

1

1

1

1

1

Accel. L

1

1

Accel. H

Accel. 3D

1

1

1

1

1

1

Particle

1

1

1

1

1

1

Seismometer

Microphone

1+1(table)

3+ 6(table)

1

1

1

1

1

Tilt meter

1

1

1

1

1

Magnetic field (3axes)

1

1

1

1

1

Name

Quantity

Low temperature monitor for suspensions

96(3ADCs) x 4sus=384

Geo IFO

Name

Laser

Center

IX

IY

EX

EY

TX

TY

control room

mine

outside

Total

Thermo. L

2

1

1

1

1

Thermo. H

4

1

1

5

5

Hygrometer

4

1

1

5

5

Barometer

4

1

1

Accel. L

2

1

1

1

1

Accel. H

Accel. 3D

4

Particle

2

Seismometer

1

1

Microphone

Tilt meter

Magnetic field (3axes)

  • IX:Room for ITMX, EX:Room for ETMX, TX:Tunnel of X arm, the same as Y

  • Thermo. L : Low resolution (~0.1K) thermometer (e.g. IC sensors monitoring instrument temp.)
  • Thermo. H : High resolution (~0.001K) thermometer (e.g. monitoring room / tunnel temp.)
  • Accel. L : Acceleration pick up (e.g. vibration monitor)
  • Accel. H : 1-dim. accelerometer (e.g. acceleration to be used for quantitative analyses)
  • Accel. 3D : 3-dim. accelerometer for 3-dim. analyses.

KAGRA/Subsystems/PEM (last edited 2012-06-06 18:31:03 by OsamuMiyakawa)