⇤ ← Revision 1 as of 2018-07-19 09:40:40
Size: 317
Comment:
|
← Revision 2 as of 2018-07-19 09:47:36 ⇥
Size: 661
Comment:
|
Deletions are marked like this. | Additions are marked like this. |
Line 6: | Line 6: |
||'''Sensor'''||'''Efficiency [um/cnt]'''|| || LVDT H1 ||<)> 0.154 || || LVDT H2 ||<)> 0.146 || || LVDT H3 ||<)> 0.150 || |
|
Line 9: | Line 15: |
'''Notes''' * We have to reboot standalone everyday. * I changed thresholds of WATCHDOG 800 for LVDT and 80000 for Geophone, because WATCHDOG always tripped during TF measurements due to the resonant peaks. |
2018/07/18
Activities
- Set a calibration factor of each LVDTs.
Sensor |
Efficiency [um/cnt] |
LVDT H1 |
0.154 |
LVDT H2 |
0.146 |
LVDT H3 |
0.150 |
- I measured TF in L, T and Y.
- The results were saved at users/tanioka/TMS/TF/20180718.
- The measurements were done by swept sine and the excitation amplitude was 3000.
Notes
- We have to reboot standalone everyday.
- I changed thresholds of WATCHDOG 800 for LVDT and 80000 for Geophone, because WATCHDOG always tripped during TF measurements due to the resonant peaks.