Line 35: Line 35:
   * Note that even after the alignment [[http://klog.icrr.u-tokyo.ac.jp/osl/?r=4561|here]], the grooves seems in the "center-to-center" relations.

20180327

Today's activities

Workers: K. Nagano, Yokogawa, Ko. Yamamoto, Sugimoto, Akutsu

  • After Uchiyama-san allowed to turn on the green laser, we did it, and went to EYT.
  • Tried to check the current situation, but the green beam got crazy many times.
    • The cause was not still clear but probably due to the BS suspension's something...
  • Brought several optical parts and the holders; see here

  • Preparations to align the BRT.
    • Attached a diaphragm (or iris) after the 2nd BRT lens; call iris-1.

    • Attached another iris (iris-2) between the 2nd mirror and the 2nd BRT lens.

    • Then the reference for the alignment work is the beam positions on the two irises along with the beam position on the 2nd mirror; see here

    • Loosened the foots of the BRT base plate, and hook up it very slightly.
  • (Pitch and )height alignment
    • Found the beam position was relatively down ... to the height of the goal!
    • So it seems, in addition to the pitch alignment on March 22, needed to do the height adjustment.
    • So did a half rotation (about 180 deg) to each leg of the BRT; each leg part (misumi SGKS10-50) has M10 screw, meaning 1.5 mm pitch, so the half screwing down each would lead 0.75 mm up of the base plate when it went back to sit on the fixed stage.
    • Still the beam position is higher than the irises, we stopped the pitch and height alignment.
  • Yaw and X-shift (translational) alignment
    • Note that the three foots of the BRT base plate were still loosen and the BRT was hooked up by the crane.
    • First I tried to rotate the base plate to align the green beam to the iris-1.
      • But the right rotation direction was opposite against what we expected...
      • Found it was impossible to say the initial position and alignment of the BRT was ACTUALLY nominal.

        • Note that the center pin and the alignment pin are fixed to the fixed stage, while combination plates (a set of two plate to accept a pin; two plates for one pin) on the BRT base plate accept the pins.
        • The only reference we were able to use to determine the combination plates is a groove on the BRT base plate (showing the nominal optical axis line); a groove on the combination plates were aligned to the groove on the base plate only in the human-eyeball-accuracy at that time.
        • The grooves are 1mm widths, while the precisions we need to tune are 0.xxx mrad and 0.xxx mm, respectively (see the short summary memo below); it is impossible to align the stuffs only refering the groove by human being.
        • Moreover note that in average in KAGRA, the accuracy of the location of the vaccum chamber would be a few mm!
    • Finally used the green-beam-itself-today as the reference.
    • First we loosened only a combination plates for the alignment pins, and rotated the BRT base plate. But the result is not so better. This somehow moved the beam position on iris-1, but the reflection point on the 2nd mirror was not improved (shifted too much in -X direction).
    • So we also loosened another combination plates, which accepted the center pin to do X-shift as well at the same time!
    • Then I pushed and pulled somehow... so that the green beam positions on iris-1, -2, and on the mirror2 were improved. The results are shown here

    • Considering the reference beam we used will not be the actual one, we don't think we need to do much more extreme alignment today, so stopped.
      • Note that even after the alignment here, the grooves seems in the "center-to-center" relations.

Short memo

  • According to "図3_EXT,EYTの位置.pptx", (1) EYT chamber center: [ -0.013, 3023.297+8.3], and (2) ETMY AR: [ -7.590557e-03 3.023372e+03] (all units are in meters).
  • So the yaw tilt to EYT would be (x1-x2)/(y1-y2)= -6.5768e-04 rad, here y1-y2= 8.2250 and x1-x2= -0.0054.
  • More precisely speaking, the primary lens of the BRT is located about 450mm "upper" from the center of EYT; so 450mm x -6.6rad = -0.296 mm shift; too small, consideringa few mm accuracy of the vacuum chamber location.
  • To avoid just a qualitative discussion, here is the rough ABCD matrix of the BRT: [ [A,B],[C,D] ]=[ [0.1,2000],[about 0,10] ].
  • The input matrix is [x, theta]=[-0.296mm, -6.5768e-04 rad]
  • -0.296*0.1+2000*-6.5768e-4=-1.34mm; actually the first term is negligible; only tilt should have the dominant effect, but still difficult to be sensed by humans without micrometers or something...
  • So in the end, I think only the green beam can be used for the alignment reference.

Next plan

  • Measure the height with a laser leveler?
  • Locate the BRT on the stage base on XXX as references.
  • Make GPT on the optical table
  • Make a model to drive signals from the TMS
  • Check the response of the TMS by swinging BS, PR2, PR3... etc... with commissioning people
  • Endのend用のフランジとりつけ。たぶん最後のほうで。
  • そこのフランジにとりつける透過光用ビューポート。まだ柏にあるはず。
  • 外側の光学定盤の上の取り回しを考えよ。

Wanted!

  • Four M10 eye bolts

  • M8 SDC bolts? to tighten the top plate to the stage body are shortened!

  • Markers (black and white)

From VIS

  • Four clean slings (from Hirata-san)