= Wide Angle Baffle at IYC = ||<>||<>||<>||<>|| ||<>| == Links to knowledge == * [[http://gwwiki.icrr.u-tokyo.ac.jp/JGWwiki/LCGT/subgroup/AOS/WideAngleBuffle|The cooling test]] * [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=6474|Wide Angle Baffle design review (Obuchi)]] * [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=7415|Requirements for heat links of WAB (Akutsu)]] * [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=7710|Temporal information links]] * [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=7588|Wide Angle Baffle assembly-procedure manual (Zeidler)]] * [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=4660|Calculations regarding the back-scattering of different Wide Angle Baffle designs (Zeidler)]] * [[https://nbviewer.jupyter.org/urls/dl.dropbox.com/s/niycmhy8178ed0y/WAB20170224.ipynb|Personal calc of WAB's stray light noise by Akutsu]]; due to several uncertain parameters there are several results and no one would know the actual effect! * Heat links positions (by Obuchi) [[attachment:fmkopgehpapgdkcc.png]] == Task list == {{{#!wiki green/solid Note: some of the tasks can be done in parallel. }}} * --(Place/install the WAB suspension)-- * --(Align the position of WAB -> take WAB back to nominal position, put off protectors))-- * --(horizontal alignment)-- * --(yaw alignment)-- * --(Move it to the saving mode.)-- * --(Back to the nominal position.)-- * --(Attach heat links)-- * --(4 soft heat links to WAB)-- * --(1 heat link btwn the top and the structure)-- * --(Attach 2 thermometers)-- * Set revised blocks under the base plate. == Pin Assignment == P23, to be connected to Cryocon#7 E and F in this order respectively. ||Pin Name||Resistance|| Equipment || Assign || Comment1 || Comment2 || Connection || ||A||75 ohm|| Thermometer S/N#2564|| V- || Green || WAB || || ||B||75 ohm|| Thermometer S/N#2564|| V+ || Black || WAB || || ||C||4 ohm|| Thermometer S/N#2564|| I- || Red || WAB || || ||D||4 ohm|| Thermometer S/N#2564|| I+ || Yellow || WAB || || ||E||75 ohm|| Thermometer S/N#360|| V- || Green || Structure || || ||F||75 ohm|| Thermometer S/N#360|| V+ || Black || Structure || || ||G||4 ohm|| Thermometer S/N#360|| I- || Red || Structure || || ||H||4 ohm|| Thermometer S/N#360|| I+ || Yellow || Structure || || Note that the pin arrangement (or the ''naming'') is mirrored compared with that of in IXC! Rather, I guess this IXC's would be correct.