Differences between revisions 3 and 4
Revision 3 as of 2017-02-16 12:08:21
Size: 1405
Editor: KojiNagano
Comment:
Revision 4 as of 2017-02-16 13:11:34
Size: 1900
Editor: KojiNagano
Comment:
Deletions are marked like this. Additions are marked like this.
Line 17: Line 17:
The aim of this experiment is demonstrating in lab scale the technique of the quantum radiation pressure noise (QRPN) reduction by measuring the ponderomotively squeezed light with the homodyne detector. With this technique, the sensitivity of KAGRA can beat the standard quantum limit. In order to demonstrate the QRPN reduction technique, the sensitivity limited by QRPN should be achieved. In this experiment, in order to enhance QRPN, it is planed to use the high finesse (~10^4^) cavity consisting of 23-mg tiny mirror and ~50-g 2.54-mirror. Using this cavity (x2), Fabry--Perot Michelson interferometer will be construed to reduce the noise other than QRPN. As a result, the QRPN in this experiment is expected to be 10^4^ times larger than that in KAGRA in therms of displacement noise (m/rtHz) although the laser light source with ~200 mW output power is used in this experiment. The aim of this experiment is demonstrating in lab scale the technique of the quantum radiation pressure noise (QRPN) reduction by measuring the ponderomotively squeezed light with the homodyne detector. With this technique, the sensitivity of KAGRA can beat the standard quantum limit.

In order to demonstrate the QRPN reduction technique, the sensitivity limited by QRPN should be achieved. In this experiment, in order to enhance QRPN, it is planed to use the high finesse (~10^4^) cavity consisting of 23-mg tiny mirror and ~50-g 2.54-cm mirror. Using this cavity (x2), Fabry--Perot Michelson interferometer will be construed to reduce the noise other than QRPN. As a result, the QRPN in this experiment is expected to be 10^4^ times larger than that in KAGRA in therms of displacement noise (m/rtHz) although the laser light source with ~200 mW output power is used in this experiment.
Line 21: Line 23:
This experiment is suspended now (2017/02/16) for lab moving.
The status before the lab moving is summarized in the related paper []
This experiment is temporarily suspended now (2017/02/16) for lab moving.
The status before the lab moving is summarized in the related paper [].
Line 27: Line 29:
 * [[http://...|(to be written)]]  1. S. Sakata, Study of the Reduction of the Radiation Pressure Noise in Gravitational Wave Detectors using the Ponderomotive Squeezing, PhD thesis, Ochanomizu University, 2008.
 2. T. Mori, Development of a high power optical cavity for optomechanical quantum nondemolition measurement, PhD thesis, University of Tokyo, 2011.
 3. M. Nakano, Study of Opt-Mechanical Cavity Control for Development of Quantum Noise Reduction in KAGRA Gravitational Wave Detector, Master thesis, University of Tokyo, 2014.
 

QND

Members

  • Seiji Karamura
  • Koji Nagano
  • Yutaro Enomoto
  • Yuzuru Sakai
  • Masayuki Nakano

Research advisor

  • Akira Furusawa

Overview

The aim of this experiment is demonstrating in lab scale the technique of the quantum radiation pressure noise (QRPN) reduction by measuring the ponderomotively squeezed light with the homodyne detector. With this technique, the sensitivity of KAGRA can beat the standard quantum limit.

In order to demonstrate the QRPN reduction technique, the sensitivity limited by QRPN should be achieved. In this experiment, in order to enhance QRPN, it is planed to use the high finesse (~104) cavity consisting of 23-mg tiny mirror and ~50-g 2.54-cm mirror. Using this cavity (x2), Fabry--Perot Michelson interferometer will be construed to reduce the noise other than QRPN. As a result, the QRPN in this experiment is expected to be 104 times larger than that in KAGRA in therms of displacement noise (m/rtHz) although the laser light source with ~200 mW output power is used in this experiment.

Current status

This experiment is temporarily suspended now (2017/02/16) for lab moving. The status before the lab moving is summarized in the related paper []. The 23 mg mirrors are kept in the desiccator in the ICRR B1 Lab and will be moved to Ando Lab (UT).

  1. S. Sakata, Study of the Reduction of the Radiation Pressure Noise in Gravitational Wave Detectors using the Ponderomotive Squeezing, PhD thesis, Ochanomizu University, 2008.
  2. T. Mori, Development of a high power optical cavity for optomechanical quantum nondemolition measurement, PhD thesis, University of Tokyo, 2011.
  3. M. Nakano, Study of Opt-Mechanical Cavity Control for Development of Quantum Noise Reduction in KAGRA Gravitational Wave Detector, Master thesis, University of Tokyo, 2014.

LCGT/AIC/QND (last edited 2017-02-16 13:53:26 by YutaroEnomoto)