Differences between revisions 2 and 5 (spanning 3 versions)
Revision 2 as of 2010-08-11 11:14:54
Size: 853
Comment:
Revision 5 as of 2011-04-30 00:37:32
Size: 891
Comment:
Deletions are marked like this. Additions are marked like this.
Line 5: Line 5:
{{attachment:whiteboard.jpg|alt text|width=300}} [[attachment:whiteboard.jpg|{{attachment:whiteboard.jpg|alt text|width=300}}]]
Line 19: Line 19:
 * f1 and f2 are quite close (11.25MHz:45MHz=1:4)  * f1 and f2 are quite close (11.25 MHz:45 MHz = 1:4)
Line 31: Line 31:
see http://gw.icrr.u-tokyo.ac.jp/JGWwiki/LCGT/subgroup/ifo/ISC/Issues for other issues. see http://gwwiki.icrr.u-tokyo.ac.jp/JGWwiki/LCGT/subgroup/ifo/ISC/Issues for other issues.

Technical issues on control scheme

Original note

alt text

Optical configuration

  • homodyne phase far from 90 deg
  • unbalanced SB with DRSE

These can be an issue with our own risk as aLIGO and AdVirgo will start with BRSE configuration and they do not plan to change the homodyne phase from 90 deg.

Input optics

  • Mach-Zehnder noise
  • AM
  • f1 and f2 are quite close (11.25 MHz:45 MHz = 1:4)

These are also unique for LCGT.

Control

  • photodetector for double demodulation (dual resonances; if we use a single PD)
  • quality of the light at OMC-REFL
  • detector noise is currently not included in the loop-noise calculation (it should!)


see http://gwwiki.icrr.u-tokyo.ac.jp/JGWwiki/LCGT/subgroup/ifo/ISC/Issues for other issues.