= Beam Reducing Telescopes = = Transmission Monitor Telescopes (TMS) =
Line 3: Line 3:

Also called "beam reducing telescope (BRT)" in LCGT.
Line 4: Line 7:
'''[[KAGRA/Subgroups/AOS| back to AOS top]]'''
Line 7: Line 11:
TBD

== Applicable Documents ==
 * Spec. for vacuum chambers
 * Optical Layout Drawing of the LCGT interferometer
 * Length Sensing and Control doc
 * Alignment Sensing and Control doc
 * CCD Monitor doc
 * Any...
 . Transmission monitors for IR/Green beams.
Line 18: Line 14:
TBD === Applicable Documents ===
 * [[http://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=1122|麻生さんによるデザイン例]]
Line 21: Line 18:
Beams for TBD  * Collect 1064nm and 532nm light transmitting ETMs.
 * Monitor the off-centering and pitch/yaw fluctuations of the ITMs/ETMs relative to the preselected optical path.
 * Monitor the shape of the beam modes that transmit the arm cavity.

=== Requirements ===
 . For each TMS,
  * 2QPDs for 1064nm are required to monitor off-centering of the beam; one is for high gain, the other is for low gain.
  * 2QPDs for 1064nm are required to monitor pitch/yaw misalignments of the beam; one is for high gain, the other is for low gain.
  * 2QPDs for 532nm are required.
  * Remote stirring mirrors for QPDs are required at least in the initial commissioning phase.
  * Remote actuators for TMS chassis would be required.
  * CCD monitors for monitoring the beam mode transmitting the ETM are required.
  * Optical levers (or equivalent local monitors) are required.
  * Suspension system will require more signal channels?
  * Shutters for high gain QPDs are required.

=== List of Channels ===
 . For each TMS,
 ||<#FFFF00>Name||<#FFFF00>Type||<#FFFF00>Input ch#||<#FFFF00>Output ch#||<#FFFF00>Purpose||<#FFFF00>Used By||
 ||QPD1H||1064nm QPD||0||4||Mon. off-centering, high gain||MIF||
 ||QPD1L||1064nm QPD||0||4||Mon. off-centering, low gain||MIF||
 ||QPD2H||1064nm QPD||0||4||Mon. misalignment, high gain||MIF||
 ||QPD2L||1064nm QPD||0||4||Mon. misalignment, low gain||MIF||
 ||QPD1G||532nm QPD||0||4||Mon. off-centering, low gain||MIF||
 ||QPD2G||532nm QPD||0||4||Mon. misalignment, low gain||MIF||
 ||Stirring mirrors for QPDs||TBD||24||0||Remote stirring mirrors for QPDs; 6x2x2ch||MIF||
 ||CCD monitor1||TBD, for 1064nm||On/Off?||VIDEO signal?||CCD monitor||---||
 ||CCD monitor2||TBD, for 532nm||On/Off?||VIDEO signal?||CCD monitor||---||
 ||Shutters||TBD||2||0||On/Off of shutters for high-gain QPDs||MIF||


 . For each TMS suspension and local sensors,
 ||<#FFFF00>Name||<#FFFF00>Type||<#FFFF00>Input ch#||<#FFFF00>Output ch#||<#FFFF00>Purpose||<#FFFF00>Used By||
 ||Actuators for TMS||TBD||12?||0||Remote actuation for TMS||---||
 ||Optical levers for TMS||TBD||0||8||OpLev QPDx2?||---||
 ||Other, related to the suspension itself ||TBD||---||---||---||---||
Line 24: Line 57:
TBD  . TBD
Line 27: Line 60:
 * BS chamber
 *

== Requirements ==
TBD

== Characteristics ==
TBD
 * At the dedicated chambers in back of ETM chambers
Line 37: Line 63:
== Inspection plans ==
TBD

== Links ==
 * [[https://dcc.ligo.org/cgi-bin/DocDB/ShowDocument?docid=29666&version=1|LIGO-T1000746-v1, Viewports Subsystem Final Design Document]]
== External Links ==
 * [[https://dcc.ligo.org/cgi-bin/DocDB/ShowDocument?docid=6559|LIGO-T0900511-v4, Modeling of Alignment Sensing and Control for Advanced LIGO]]
 * [[https://dcc.ligo.org/cgi-bin/private/DocDB/ShowDocument?docid=4559|LIGO-T0900385-v7, The advanced LIGO ETM transmission monitor]]
 * [[https://dcc.ligo.org/cgi-bin/private/DocDB/ShowDocument?docid=11582|LIGO-T1000247-v3, ISC Gouy phase telescopes]]
 * [[https://dcc.ligo.org/cgi-bin/DocDB/ShowDocument?docid=62886|LIGO-E1100537-v10, Transmission Monitor Telescope Suspension (TMS) Final Design]]
 * [[https://dcc.ligo.org/cgi-bin/DocDB/ShowDocument?docid=60926|LIGO-G1100439-v4, TMS Telescope Alignment]]
 * [[https://dcc.ligo.org/cgi-bin/DocDB/ShowDocument?docid=58277|LIGO-T1100258-v4, Transmission Monitoring Telescope and Suspension - TMS]]

Transmission Monitor Telescopes (TMS)

Related subgroups: IOO, MIF, VAC, CRY, VIS...

Also called "beam reducing telescope (BRT)" in LCGT.


back to AOS top

Scope

  • Transmission monitors for IR/Green beams.

General Description

Applicable Documents

Functions

  • Collect 1064nm and 532nm light transmitting ETMs.
  • Monitor the off-centering and pitch/yaw fluctuations of the ITMs/ETMs relative to the preselected optical path.
  • Monitor the shape of the beam modes that transmit the arm cavity.

Requirements

  • For each TMS,
    • 2QPDs for 1064nm are required to monitor off-centering of the beam; one is for high gain, the other is for low gain.
    • 2QPDs for 1064nm are required to monitor pitch/yaw misalignments of the beam; one is for high gain, the other is for low gain.
    • 2QPDs for 532nm are required.
    • Remote stirring mirrors for QPDs are required at least in the initial commissioning phase.
    • Remote actuators for TMS chassis would be required.
    • CCD monitors for monitoring the beam mode transmitting the ETM are required.
    • Optical levers (or equivalent local monitors) are required.
    • Suspension system will require more signal channels?
    • Shutters for high gain QPDs are required.

List of Channels

  • For each TMS,

    Name

    Type

    Input ch#

    Output ch#

    Purpose

    Used By

    QPD1H

    1064nm QPD

    0

    4

    Mon. off-centering, high gain

    MIF

    QPD1L

    1064nm QPD

    0

    4

    Mon. off-centering, low gain

    MIF

    QPD2H

    1064nm QPD

    0

    4

    Mon. misalignment, high gain

    MIF

    QPD2L

    1064nm QPD

    0

    4

    Mon. misalignment, low gain

    MIF

    QPD1G

    532nm QPD

    0

    4

    Mon. off-centering, low gain

    MIF

    QPD2G

    532nm QPD

    0

    4

    Mon. misalignment, low gain

    MIF

    Stirring mirrors for QPDs

    TBD

    24

    0

    Remote stirring mirrors for QPDs; 6x2x2ch

    MIF

    CCD monitor1

    TBD, for 1064nm

    On/Off?

    VIDEO signal?

    CCD monitor

    ---

    CCD monitor2

    TBD, for 532nm

    On/Off?

    VIDEO signal?

    CCD monitor

    ---

    Shutters

    TBD

    2

    0

    On/Off of shutters for high-gain QPDs

    MIF

  • For each TMS suspension and local sensors,

    Name

    Type

    Input ch#

    Output ch#

    Purpose

    Used By

    Actuators for TMS

    TBD

    12?

    0

    Remote actuation for TMS

    ---

    Optical levers for TMS

    TBD

    0

    8

    OpLev QPDx2?

    ---

    Other, related to the suspension itself

    TBD

    ---

    ---

    ---

    ---

Naming Conventions

  • TBD

Locations

  • At the dedicated chambers in back of ETM chambers