Differences between revisions 31 and 32
Revision 31 as of 2012-07-13 22:13:26
Size: 3570
Comment:
Revision 32 as of 2012-09-16 20:35:15
Size: 3598
Editor: KiwamuIzumi
Comment:
Deletions are marked like this. Additions are marked like this.
Line 7: Line 7:
'''[[../|..Up]]''' '''[[KAGRA/Subgroups/AOS| back to AOS top]]'''

Transmission Monitor System (TMS)

Related subgroups: IOO, MIF, VAC, CRY, VIS...

Also called "beam reducing telescope (BRT)" in LCGT.


back to AOS top

Scope

Transmission monitors for IR/Green beams.

General Description

Applicable Documents

Functions

  • Collect 1064nm and 532nm light transmitting ETMs.
  • Monitor the off-centering and pitch/yaw fluctuations of the ITMs/ETMs relative to the preselected optical path.
  • Monitor the shape of the beam modes that transmit the arm cavity.

Requirements

For each TMS,

  • 2QPDs for 1064nm are required to monitor off-centering of the beam; one is for high gain, the other is for low gain.
  • 2QPDs for 1064nm are required to monitor pitch/yaw misalignments of the beam; one is for high gain, the other is for low gain.
  • 2QPDs for 532nm are required.
  • Remote stirring mirrors for QPDs are required at least in the initial commissioning phase.
  • Remote actuators for TMS chassis would be required.
  • CCD monitors for monitoring the beam mode transmitting the ETM are required.
  • Optical levers (or equivalent local monitors) are required.
  • Suspension system will require more signal channels?
  • Shutters for high gain QPDs are required.

List of Channels

For each TMS,

Name

Type

Input ch#

Output ch#

Purpose

Used By

QPD1H

1064nm QPD

0

4

Mon. off-centering, high gain

MIF

QPD1L

1064nm QPD

0

4

Mon. off-centering, low gain

MIF

QPD2H

1064nm QPD

0

4

Mon. misalignment, high gain

MIF

QPD2L

1064nm QPD

0

4

Mon. misalignment, low gain

MIF

QPD1G

532nm QPD

0

4

Mon. off-centering, low gain

MIF

QPD2G

532nm QPD

0

4

Mon. misalignment, low gain

MIF

Stirring mirrors for QPDs

TBD

24

0

Remote stirring mirrors for QPDs; 6x2x2ch

MIF

CCD monitor1

TBD, for 1064nm

On/Off?

VIDEO signal?

CCD monitor

---

CCD monitor2

TBD, for 532nm

On/Off?

VIDEO signal?

CCD monitor

---

Shutters

TBD

2

0

On/Off of shutters for high-gain QPDs

MIF

For each TMS suspension and local sensors,

Name

Type

Input ch#

Output ch#

Purpose

Used By

Actuators for TMS

TBD

12?

0

Remote actuation for TMS

---

Optical levers for TMS

TBD

0

8

OpLev QPDx2?

---

Other, related to the suspension itself

TBD

---

---

---

---

Naming Conventions

TBD

Locations

  • At the dedicated chambers in back of ETM chambers

LCGT/subgroup/AOS/BeamReduceTelescope1 (last edited 2012-09-28 03:45:15 by TomotadaAkutsu)