= Transmission Monitor System (TMS) = = Transmission Monitor Telescopes (TMS) =

Transmission Monitor Telescopes (TMS)

Related subgroups: IOO, MIF, VAC, CRY, VIS...

Also called "beam reducing telescope (BRT)" in LCGT.


back to AOS top

Scope

  • Transmission monitors for IR/Green beams.

General Description

Applicable Documents

Functions

  • Collect 1064nm and 532nm light transmitting ETMs.
  • Monitor the off-centering and pitch/yaw fluctuations of the ITMs/ETMs relative to the preselected optical path.
  • Monitor the shape of the beam modes that transmit the arm cavity.

Requirements

  • For each TMS,
    • 2QPDs for 1064nm are required to monitor off-centering of the beam; one is for high gain, the other is for low gain.
    • 2QPDs for 1064nm are required to monitor pitch/yaw misalignments of the beam; one is for high gain, the other is for low gain.
    • 2QPDs for 532nm are required.
    • Remote stirring mirrors for QPDs are required at least in the initial commissioning phase.
    • Remote actuators for TMS chassis would be required.
    • CCD monitors for monitoring the beam mode transmitting the ETM are required.
    • Optical levers (or equivalent local monitors) are required.
    • Suspension system will require more signal channels?
    • Shutters for high gain QPDs are required.

List of Channels

  • For each TMS,

    Name

    Type

    Input ch#

    Output ch#

    Purpose

    Used By

    QPD1H

    1064nm QPD

    0

    4

    Mon. off-centering, high gain

    MIF

    QPD1L

    1064nm QPD

    0

    4

    Mon. off-centering, low gain

    MIF

    QPD2H

    1064nm QPD

    0

    4

    Mon. misalignment, high gain

    MIF

    QPD2L

    1064nm QPD

    0

    4

    Mon. misalignment, low gain

    MIF

    QPD1G

    532nm QPD

    0

    4

    Mon. off-centering, low gain

    MIF

    QPD2G

    532nm QPD

    0

    4

    Mon. misalignment, low gain

    MIF

    Stirring mirrors for QPDs

    TBD

    24

    0

    Remote stirring mirrors for QPDs; 6x2x2ch

    MIF

    CCD monitor1

    TBD, for 1064nm

    On/Off?

    VIDEO signal?

    CCD monitor

    ---

    CCD monitor2

    TBD, for 532nm

    On/Off?

    VIDEO signal?

    CCD monitor

    ---

    Shutters

    TBD

    2

    0

    On/Off of shutters for high-gain QPDs

    MIF

  • For each TMS suspension and local sensors,

    Name

    Type

    Input ch#

    Output ch#

    Purpose

    Used By

    Actuators for TMS

    TBD

    12?

    0

    Remote actuation for TMS

    ---

    Optical levers for TMS

    TBD

    0

    8

    OpLev QPDx2?

    ---

    Other, related to the suspension itself

    TBD

    ---

    ---

    ---

    ---

Naming Conventions

  • TBD

Locations

  • At the dedicated chambers in back of ETM chambers