Size: 613
Comment:
|
Size: 2471
Comment:
|
Deletions are marked like this. | Additions are marked like this. |
Line 1: | Line 1: |
= Optical Lever = | = Optical Lever (Room Temperature) = |
Line 4: | Line 4: |
'''[[../|..Up]]''' | |
Line 7: | Line 8: |
Optical lever for LCGT-SAS system | Sensing local motions including --(longitudinal dof and)-- all alignment dofs (pitch, yaw and roll) of any mirrors supported by vibration isolation system. <!> Note on the operating temperature: here the system is assumed to be utilized at room temperature, not in cryogenic temperature. |
Line 10: | Line 15: |
* Spec. for vacuum chambers * Any... |
TBD; just see the links below. |
Line 14: | Line 18: |
Line 23: | Line 28: |
* | * ITM chambers (X,Y) * ETM chambers (X,Y) * PRC chambers (PRC, PR2, PR3) * SRC chambers (SRC, SR2, SR3) * MC chambers (MC1, MC2...) |
Line 26: | Line 35: |
TBD | * Sensor noise should be less than xxx. * Sensor's dynamic range should be greater than xxx. * At least horizontal degrees of freedom (X,Y) * Preferably a vertical sensor (Z) and side * The sensors have to be rigidly mounted on the ground so that these are useful for remembering the position of the mirror and recording the drifts. |
Line 35: | Line 48: |
== Procurement process and plans == TBD <<Anchor(Links)>> |
|
Line 36: | Line 54: |
* [[https://dcc.ligo.org/cgi-bin/DocDB/ShowDocument?docid=29666&version=1|LIGO-T1000746-v1, Viewports Subsystem Final Design Document]] | <!> Some of the LIGO documents listed below are '''NOT''' public; to access them, you may need your own LSC account. * [[https://dcc.ligo.org/cgi-bin/private/DocDB/ShowDocument?docid=22686|LIGO-M1000343, Advanced LIGO Review Committee Report: Test Mass Optical Lever FDR]] * [[https://dcc.ligo.org/cgi-bin/private/DocDB/ShowDocument?docid=15032|LIGO-T1000517, Optical levers Final Design Review for test masses, recycler mirrors and HAM optical benches]] * [[https://dcc.ligo.org/cgi-bin/private/DocDB/ShowDocument?docid=70690|LIGO-G1100961, Long-Term Stability Test for aLIGO Optical Levers]] * * [[http://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=418|JGW-G1100418, LCGT vacuum chamber envelope study]] * [[https://dcc.ligo.org/cgi-bin/private/DocDB/ShowDocument?docid=15271|LIGO-T1000533, Super-luminescent LED 21 and 50 day trend analysis]] * [[https://dcc.ligo.org/cgi-bin/private/DocDB/ShowDocument?docid=13338|LIGO-T1000390, Trade-off Study for the Optical Lever Light Source]] * [[https://dcc.ligo.org/cgi-bin/private/DocDB/ShowDocument?docid=11010|LIGO-T1000219, Test mass optical levers preliminary design]] |
Optical Lever (Room Temperature)
Related subgroups: VIS, IOO, MIF, VAC, CRY...
Contents
Scope
Sensing local motions including longitudinal dof and all alignment dofs (pitch, yaw and roll) of any mirrors supported by vibration isolation system.
Note on the operating temperature: here the system is assumed to be utilized at room temperature, not in cryogenic temperature.
Applicable Documents
TBD; just see the links below.
General Description
Receiver and Transmitter
Naming Conventions
TBD
Locations
- BS chamber
- ITM chambers (X,Y)
- ETM chambers (X,Y)
- PRC chambers (PRC, PR2, PR3)
- SRC chambers (SRC, SR2, SR3)
- MC chambers (MC1, MC2...)
Requirements
- Sensor noise should be less than xxx.
- Sensor's dynamic range should be greater than xxx.
- At least horizontal degrees of freedom (X,Y)
- Preferably a vertical sensor (Z) and side
- The sensors have to be rigidly mounted on the ground so that these are useful for remembering the position of the mirror and recording the drifts.
Characteristics
TBD
Inspection plans
TBD
Procurement process and plans
TBD
Links
Some of the LIGO documents listed below are NOT public; to access them, you may need your own LSC account.