Size: 190
Comment:
|
Size: 2888
Comment:
|
Deletions are marked like this. | Additions are marked like this. |
Line 2: | Line 2: |
Line 6: | Line 5: |
=== Interferometer Diagram === {{attachment:MIF-diagram.png|MIF Diagram|width="800"}} |
|
Line 7: | Line 8: |
{{attachment:MIF-diagram.png|MIF Diagram|width=800}} | ---- === g1=-0.7857, g2=-0.6043, 16.875MHz, 45MHz === This is the parameter set chosen by the MIF group. |
Line 9: | Line 12: |
==== Lengths & Frequencies ==== ||f1 ||16.880962MHz (3*f2/8) ||f2 ||45.015898MHz ||f3 ||56.269873MHz (10*f2/8) || ||Larm ||3000.0m ||Lmc ||26.639m ||||<style="text-align:center"> || ||Lprc ||66.591m ||Lsrc ||66.591m ||Las ||3.3299m || ||Lp1 ||14.7606 ||Lp2 ||11.0669m ||Lp3 ||15.7638m || ||Lmi ||25m ||Lmx ||26.6649m ||Lmy ||23.3351m || ||Ls1 ||14.7606m ||Ls2 ||11.0669m ||Ls3 ||15.7638m || ||Folding angle ||0.6860[deg] ||||||||<style="text-align:center"> || Folding angle is an incident angle of the beam to the folding mirrors. The angle between incoming and reflected beams is twice the folding angle. ==== Radius of Curvatures (Positive for concave) ==== ||ITM ||1680.0m ||ETM ||1870.0m ||||<style="text-align:center"> || ||PRM ||303.96m ||PR2 ||-2.7628m ||PR3 ||24.574m || ||SRM ||303.96m ||SR2 ||-2.7764m ||SR3 ||24.584m || ==== Beam Spot Size (1/e^2 radius) ==== ||ITM ||35.064mm ||ETM ||39.983mm ||||<style="text-align:center"> || ||PRM ||4.030mm ||PR2 ||4.030mm ||PR3 ||36.479mm || ||SRM ||4.031mm ||SR2 ||4.031mm ||SR3 ||36.327mm || ==== Lens effect (effective focal length seen from the AR side) ==== ||ITM (Sapphire) ||>666km || ||PRM (Silica) ||>10000km || ---- || || || || || || ---- |
|
Line 10: | Line 50: |
=== Test Masses === '''ITM''' ||HR Radius of Curvature ||1.68(+/-0.008)km ||0.5% error || ||AR Radius of Curvature ||Flat (>100km) ||As flat as possible || ||AR Wedge Angle ||0.2+/-0.002deg || || ||Transmission@1064nm ||0.004 +0.001/-0.0 || || ||Transmission asymmetry@1064nm ||2*|(T1-T2)/(T1+T2)| < 0.01 ||T1 and T2 are the transmission of two ITMs || ||HR Loss@1064nm ||<45ppm || || ||Transmission@532nm ||0.2(+/-0.1) ||Transmission of ITM must be larger than ETM@532nm || ||Transmission asymmetry@532nm ||No requirement || || ||HR Loss@532nm ||<1% || || ||AR Reflectivity@1064nm ||200(+100/-0)ppm || || ||AR Reflectivity@532nm ||<5% ||As small as possible || '''ETM''' ||HR Radius of Curvature ||1.87(+/-0.009)km ||0.5% error || ||AR Radius of Curvature ||Flat (>100km) ||As flat as possible || ||AR Wedge Angle ||0.2+/-0.1deg || || ||Transmission@1064nm ||5ppm < T < 10ppm || || ||Transmission asymmetry@1064nm ||2*|(T1-T2)/(T1+T2)| < 0.01 ||Best Effort || ||HR Loss@1064nm ||<45ppm || || ||Transmission@532nm ||0.2(+/-0.01) ||Transmission of ETM must be smaller than ITM@532nm || ||Transmission asymmetry@532nm ||No requirement || || ||HR Loss@532nm ||<1% || || ||AR Reflectivity@1064nm ||200(+100/-0)ppm || || ||AR Reflectivity@532nm ||<5% ||As small as possible || |
Actual Optical Parameters of the Main Interferometer
Contents
Optical Parameters
Interferometer Diagram
g1=-0.7857, g2=-0.6043, 16.875MHz, 45MHz
This is the parameter set chosen by the MIF group.
Lengths & Frequencies
f1 |
16.880962MHz (3*f2/8) |
f2 |
45.015898MHz |
f3 |
56.269873MHz (10*f2/8) |
Larm |
3000.0m |
Lmc |
26.639m |
|
|
Lprc |
66.591m |
Lsrc |
66.591m |
Las |
3.3299m |
Lp1 |
14.7606 |
Lp2 |
11.0669m |
Lp3 |
15.7638m |
Lmi |
25m |
Lmx |
26.6649m |
Lmy |
23.3351m |
Ls1 |
14.7606m |
Ls2 |
11.0669m |
Ls3 |
15.7638m |
Folding angle |
0.6860[deg] |
|
Folding angle is an incident angle of the beam to the folding mirrors. The angle between incoming and reflected beams is twice the folding angle.
Radius of Curvatures (Positive for concave)
ITM |
1680.0m |
ETM |
1870.0m |
|
|
PRM |
303.96m |
PR2 |
-2.7628m |
PR3 |
24.574m |
SRM |
303.96m |
SR2 |
-2.7764m |
SR3 |
24.584m |
Beam Spot Size (1/e^2 radius)
ITM |
35.064mm |
ETM |
39.983mm |
|
|
PRM |
4.030mm |
PR2 |
4.030mm |
PR3 |
36.479mm |
SRM |
4.031mm |
SR2 |
4.031mm |
SR3 |
36.327mm |
Lens effect (effective focal length seen from the AR side)
ITM (Sapphire) |
>666km |
PRM (Silica) |
>10000km |
|
|
|
|
Mirror Specs
Test Masses
ITM
HR Radius of Curvature |
1.68(+/-0.008)km |
0.5% error |
AR Radius of Curvature |
Flat (>100km) |
As flat as possible |
AR Wedge Angle |
0.2+/-0.002deg |
|
Transmission@1064nm |
0.004 +0.001/-0.0 |
|
Transmission asymmetry@1064nm |
2*|(T1-T2)/(T1+T2)| < 0.01 |
T1 and T2 are the transmission of two ITMs |
HR Loss@1064nm |
<45ppm |
|
Transmission@532nm |
0.2(+/-0.1) |
Transmission of ITM must be larger than ETM@532nm |
Transmission asymmetry@532nm |
No requirement |
|
HR Loss@532nm |
<1% |
|
AR Reflectivity@1064nm |
200(+100/-0)ppm |
|
AR Reflectivity@532nm |
<5% |
As small as possible |
ETM
HR Radius of Curvature |
1.87(+/-0.009)km |
0.5% error |
AR Radius of Curvature |
Flat (>100km) |
As flat as possible |
AR Wedge Angle |
0.2+/-0.1deg |
|
Transmission@1064nm |
5ppm < T < 10ppm |
|
Transmission asymmetry@1064nm |
2*|(T1-T2)/(T1+T2)| < 0.01 |
Best Effort |
HR Loss@1064nm |
<45ppm |
|
Transmission@532nm |
0.2(+/-0.01) |
Transmission of ETM must be smaller than ITM@532nm |
Transmission asymmetry@532nm |
No requirement |
|
HR Loss@532nm |
<1% |
|
AR Reflectivity@1064nm |
200(+100/-0)ppm |
|
AR Reflectivity@532nm |
<5% |
As small as possible |