年間電力消費量試算 by Kuroda | == 変電設備 == |
Line 3: | Line 3: |
|| 冷凍機圧縮機 || 24台×11kW || 264kW×24×365×100% ||<)>2,312,640 kWh || || 計算機(空調込) || || 80kW×24×365×100% ||<)> 700,800 kWh || || 真空ポンプ || || 50kW×24×365× 5% ||<)> 21,900 kWh || || 測定器・電気装置 || || 5kW×12×365×100% ||<)> 21,900 kWh || || 坑内空調機(含フィルター) || || 10kW×12×365×100% ||<)> 43,800 kWh || || 照明 トンネル部分 || || 2kW×24×365× 20% ||<)> 3,504 kWh || || 冷却水循環ポンプ || || 1kW×24×365×100% ||<)> 8,760 kWh || || 真空槽室 || || 1kW×24×365×100% ||<)> 8,760 kWh || || 年間合計 || || ||<)> 3,122,064 kWh || |
== 配電盤 == == 年間電力使用量試算 by Kuroda == || Compressor for cryocooler <<FootNote(24台×11kW)>> ||<)> 264kW || ×24×365×100% ||<)>2,312,640 kWh || || Computer w/ air conditioner ||<)> 80kW || ×24×365×100% ||<)> 700,800 kWh || || Vacuum pupm ||<)> 50kW || ×24×365× 5% ||<)> 21,900 kWh || || Measurement instruments ||<)> 5kW || ×12×365×100% ||<)> 21,900 kWh || || Air conditioner w/ HEPA ||<)> 10kW || ×12×365×100% ||<)> 43,800 kWh || || Lighting equipment ||<)> 2kW || ×24×365× 20% ||<)> 3,504 kWh || || Cooling water pump ||<)> 1kW || ×24×365×100% ||<)> 8,760 kWh || || Vacuum tanks (center room) ||<)> 1kW || ×24×365×100% ||<)> 8,760 kWh || || || || || || || Total sum. ||<)> 413kW || ||<)> 3,122,064 kWh || |
Line 14: | Line 19: |
変電設備
配電盤
年間電力使用量試算 by Kuroda
Compressor for cryocooler 1 |
264kW |
×24×365×100% |
2,312,640 kWh |
Computer w/ air conditioner |
80kW |
×24×365×100% |
700,800 kWh |
Vacuum pupm |
50kW |
×24×365× 5% |
21,900 kWh |
Measurement instruments |
5kW |
×12×365×100% |
21,900 kWh |
Air conditioner w/ HEPA |
10kW |
×12×365×100% |
43,800 kWh |
Lighting equipment |
2kW |
×24×365× 20% |
3,504 kWh |
Cooling water pump |
1kW |
×24×365×100% |
8,760 kWh |
Vacuum tanks (center room) |
1kW |
×24×365×100% |
8,760 kWh |
|
|
|
|
Total sum. |
413kW |
|
3,122,064 kWh |
24台×11kW (1)