Differences between revisions 39 and 40
Revision 39 as of 2018-11-18 19:03:51
Size: 3203
Comment:
Revision 40 as of 2018-11-18 21:44:09
Size: 3193
Editor: YukiInoue
Comment:
Deletions are marked like this. Additions are marked like this.
Line 2: Line 2:
 * Transfer function
 * Relative power Noise
 * Longtime injection
 * Enviroment monitor
 * WSK calibration
== TF,Noise ==
[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=9278|data]

Run01 (2018/11/1~11/3)

TF,Noise

[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=9278|data]

The measurement condition, measurement "Unix" time (not GPS time), and corresponding channels

Measurement condition

Unix start time

Unix finish time

channels

Without WSK, Path1

1541157539.418005

1541157839.8215971

TxPD1, OFSPD1, RxPD

Without WSK, Path2

1541157909.4979379

1541158200.728071

TxPD2, OFSPD2, RxPD

WSK at Tx module exit, Path1

1541156396.084233

1541156695.7076631

TxPD1, OFSPD1, WSK

WSK at Tx module exit, Path2

1541156891.447325

1541157194.656775

TxPD2, OFSPD2, WSK

WSK at Tx module exit, Laser off

1541157279.23807

1541157383.5417781

TxPD1, OFSPD1, TxPD2, OFSPD2, WSK

WSK at Rx module entrance, Path1

1541154371.3472719

1541154722.988471

TxPD1, OFSPD1, WSK

WSK at Rx module entrance, Path2

1541155076.5712309

1541155414.8761361

TxPD2, OFSPD2, WSK

WSK at Rx module entrance, Laser off

1541155503.024539

1541155632.5346031

TxPD1, OFSPD1, TxPD2, OFSPD2, WSK

TxPD1=K1:CAL-PCAL_EX_1_PD_TX_V_DQ

TxPD2=K1:CAL-PCAL_EX_2_PD_TX_V_DQ

OFSPD1=K1:CAL-PCAL_EX_1_PD_OFS_V_DQ

OFSPD2=K1:CAL-PCAL_EX_2_PD_OFS_V_DQ

RxPD=K1:CAL-PCAL_EX_1_PD_RX_V_DQ

Memo: Above 5 channels:

  • - Sampling rate = 16,384 Hz
  • - Type = float (not double!!)

Environmental channels

  • K1:CAL-PCAL_EX_ACC_RX_OUT_DQ
    • TEAC 706 accelerometer on the Rx module
  • K1:CAL-PCAL_EX_ACC_TX_OUT_DQ
    • TEAC 706 accelerometer on the Tx module
  • K1:CAL-PCAL_EX_MIC_OUT_DQ
    • ACO microphone near the Rx module

    Memo: Above 3 channels:
    • - Sampling rate = 2,048 Hz
    • - Type = float (not double!!)

  • You can check after restart the model at Nov. 3rd (around 17:30 JST)
  • Working time is same as PCal maintenance

Unix Time <---> GPS time

  • Unix Time = 1500000000 <---> GPS Time = 1184035218

  • Unix Time = 1541150000 <---> GPS Time = 1225185218 (Nov 02, 2018. 09:13:20 UTC = Nov 02, 2018. 18:13:20 JST)

  • Unix Time = 1541155000 <---> GPS Time = 1225190218 (Nov 02, 2018. 10:36:40 UTC = Nov 02, 2018. 19:36:40 JST)


  • Unix Time = 1541084400 <---> GPS Time = 1225119618 (Nov 01, 2018. 15:00:00 UTC = Nov 02, 2018. 00:00:00 JST)

  • Unix Time = 1541170800 <---> GPS Time = 1225206018 (Nov 02, 2018. 15:00:00 UTC = Nov 03, 2018. 00:00:00 JST)

  • Unix Time = 1541257200 <---> GPS Time = 1225292418 (Nov 03, 2018. 15:00:00 UTC = Nov 04, 2018. 00:00:00 JST)

  • Unix Time = 1541343600 <---> GPS Time = 1225378818 (Nov 04, 2018. 15:00:00 UTC = Nov 05, 2018. 00:00:00 JST)

Other Info.

  • PCAL
    K1:CAL-PCAL_[EX,EY]_[1,2]_PD_[TX,RX,OFS]_V_DQ 16,384 Hz
    K1:CAL-PCAL_[EX,EY]_TEMP_[TX,RX,LASERINT] 16 Hz
    K1:CAL-PCAL_[EX,EY]_LASER_TEMPDIOD 16 Hz

  • Baffle PD
    K1:AOS-[EXC,EYC,IXA]_BAFFLEPD_xxxx 16 Hz

  • EMTX OPLEV
    K1:VIS-ETMX_TM_OPLEV_xxxx 16 Hz or 2,048 Hz

  • PSL?? (ref caV, MZM, PMC, IMC, ...)

  • ...(will add more channels later as necessary)...

Run01 (last edited 2018-11-21 23:39:49 by YukiInoue)