Check if the real time models are sending data to DAQ
DC status on each mode's GDS_TP screen should be 0x0.
1. Open sitemap on an workstation
$sc $medm sitemap.adl
2. Open CDS screen
3. Open GDS_TP screen of each model (blue buttons)
4. Check that "DC Status" is 0x0
DC status |
What to do |
0x0 |
Good status! |
x4000 |
It is OK. Data is being sent and you can leave it. There is some synchronization error. |
x2000 |
It is OK. Data is being sent and you can leave it. There is some synchronization error. |
0x2bad |
Bad. The real time model is not sending data to the data concentrator machine, k1dc0. Go to (1) |
blank |
Bad. Channels are not registered to send to k1dc0. Go to (2) |
When DC status is blank
1. First check
make sure the model's channel list is registered in master.
t cd fb emacs master
Check if
- tpchn_modelname.par
- MODELNAME.ini
are written in the file.
2. If master is ok, but still blank, or, if you changed master file
Before doing this, let everyone know that DQ will be killed
ssh k1dc0 ps -ef | grep daqd
Check the process number of daqd. There may be two or three and pick the first and left number (###).
kill ###
daqd process will automatically start up again, and the DAC status will be cleared.
3. If neither above did not work
Reboot the data concentrator:
ssh k1dc0 sudo reboot
Wait patiently until k1dc0 restarts.
4. Rebooting did not work
Call Osamu or Keiko.