Check if the real time models are sending data to DAQ
1. Open sitemap on an workstation
$sc $medm sitemap.adl
2. Open CDS screen
3. Open GDS_TP screen of each model (blue buttons)
4. Check that "DC Status" is 0x0
DC status |
What to do |
0x0 |
Good status! |
x4000 |
Data is being sent and you can leave it. Master IOP gets it when the timing synchronization is fuked up. |
x2000 |
When the master IOP's timing is not synchrimized properly, slave model shows this code. |
0x2 |
Real time model is not sending data to k1dc0 machine. Go to (1) |
(1)
ssh <FE macehine name such as k1pr0> sudo /etc/init.d/mx_stream restart
(2)
ps -ef | grep daqd
Check the process number of daqd. There may be two or three and pick the first and left number (###).
kill ###
daqd process will automatically start up again, and the DAC status will be cleared.