Line 2: | Line 4: |
* When FPMI cannot keep lock state for over 10 minutes or cannot got to lock state ---> call operation shift members. | * Operator shift table in [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=10914|JGW-M1910914]] * Some information for collaborator shifts in [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=9380|JGW-M1809380]] |
Line 5: | Line 7: |
* Collaboration shift routine tasks | ------ == Collaboration shift routine tasks == |
Line 7: | Line 10: |
. <<TableOfContents(2)>> | 1. When FPMI cannot keep locked state for over 10 minutes or cannot got to lock state ---> call operator shift members * contact person (operator shift) on the day is listed with '''PHONE NUMBER''' around white board in the control room or see the link [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=10914|JGW-M1910914]] (no phone number in this list) |
Line 9: | Line 14: |
== Control Room Overview == * IFO Monitor: shows the status of the Main Interferometer . {{attachment:IFO1.png||width="630"}} * CCD Monitor: . {{attachment:ccd monitor.png||height="681"}} * DAQ/VIS status: . {{attachment:vis status.png||height="681"}} * PEM Monitor: Room temperature/ Vacuum pressure . {{attachment:Pem.jpg||width="630"}} * Time: show JST/UTC/GPS time . {{attachment:GPS t ime.jpg||width="430"}} |
* Write "Log book" ([[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=11124|JGW-E1911124]]) on the desk in the control room. * Check Guardian status for 5 items, LSC, VIS, IO, Green laser and ALS. Instruction is in below. * Put check mark every 2 hours. * Write down everything you noticed. * Example: lock lost, earthquake, somebody entered mine etc. * Please write [[http://klog.icrr.u-tokyo.ac.jp/osl/|klog]]: [[http://klog.icrr.u-tokyo.ac.jp/osl/]] before you leave control room. * Writing [[http://klog.icrr.u-tokyo.ac.jp/osl/|klog]] is very important. This is only one tool which can show the status in the control room to outside. * Account name and password are shown on the white board in the control room. * Leave message on "Takeover note" ([[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=5032|JGW-T1605032]]) on the desk in the control room if you have something to tell to the next shift. * Improve this wiki page if you had something you did not understand well and you found what it is. 1. Search "KAGRA wiki" in google and access to KAGRA top page. * Go to ERun top page on the second line of KAGRA Top page, and go to "Collaborator shift manuals". That page is this manual. * Login KAGRA wiki, and press "Edit" button around the top left. * Account name and password are shown on the white board in the control room. ------ ------ === 1. Interferometer locking status screen === * Please check the interferometer locking screen first. If the status is not "LOCKED", something might happen. * If FPMI cannot keep "LOCKED" state for over 10 minutes or cannot got back to "LOCKED" state, please contact operator shift. {{attachment:IFOstatus_s.png||width="800"}} |
Line 22: | Line 39: |
== How to use Guardian == === Accessing to the guardian screen === . In the desktop, you can click on the sitemap. . {{attachment:111.png||width="330"}} . {{attachment:112.png||width="430"}} |
=== 2. Accessing to the guardian screen === . On the desktop, you can click the sitemap. . {{attachment:112.png||width="630"}} |
Line 28: | Line 44: |
. {{attachment:114.png||width="730"}} . {{attachment:guardian_explanation.png||width=""}} === Knowing the current state and requested state === . {{attachment:guardian_howto4.png||height="281",width="434"}} === How to request a state === . Click on the gray bar in the middle.<<BR>> {{attachment:guardian_howto.png||height="298",width="433"}} <<BR>> Then, choose the desired state.<<BR>> {{attachment:guardian_howto2.png||height="299",width="434"}} == Check list of the interferometer == . Look at the Guardian overview, check if all of VIS Guardians are in ALIGNED state. {{attachment:VIS guardian.png||height="",width="880"}} OR you can see the VIS status on the Monitor {{attachment:VIS guardian 2.png||height="",width="680"}} *If the Guardian is in TRIPPED state, you should [[http://gwwiki.icrr.u-tokyo.ac.jp/JGWwiki/KAGRA/Commissioning/Phase1/Operation/ShiftManual#How_to_reset_Watch_Dogs|reset Watch Dogs (WDs)]], OR call operation shift members. |
. {{attachment:116.png||width="730"}} |
Line 44: | Line 47: |
= Check list of the interferometer = === Check if the LSC_LOCK Guardian at OBSERVATION state === {{attachment:LCSLOCK.png||height="",width="880"}} |
|
Line 45: | Line 51: |
<<BR>>If "OFF", check the guardian overview screen<<BR>> {{attachment:guardian_howto3.png||height="281",width="434"}} <<BR>>Check the state of LSC_MICH. First check if the request state of LSC_MICH is OPERATION. If it is not, request OPERATION.<<BR>> {{attachment:guardian_howto4.png||height="281",width="434"}} . If the state is ''READY, ENGAGE_SERVO, ENGAGE_BOOST, MICH_LOCKED, CALIBRATION_INJECTION'', or ''ACTUATORCAL_INJECTION'', the interferometer is now on the way to be OPERATION state. It will be ready soon. <<BR>> /!\ ''' If it does not enter OPERATION state in a few mins. Call the interferometer experts.'''<<BR>> Check the status of ''IMC_LOCK, VIS_BS, VIS_PR2, VIS_PR3''. (Note that ''VIS_PRM'' is not used for now, so just ignore it) <<BR>>For IMC_LOCK, every thing should be green and IMC should be back automatically. <<BR>> {{attachment:IMC_guardian.png||height="293",width="453"}} <<BR>> For example, this is how the IMC_LOCK guardian should normally look like.<<BR>> {{attachment:IMC_guardian_status.png||height="281",width="407"}} <<BR>> /!\ '''If it does not come back in ~ 10 mins, call interferometer/IOO experts.'''<<BR>> For VIS_PR2 and VIS_BS, the state should be ALIGNED. If inot, a notification "please reset Watch Dog!" will show up, and the state is in TRIPPED. In that case, go to the next section to know how to reset Watch Dog. <<BR>> For VIS_PR3, the state should be DAMPED. If it is not, a notification "please reset Watch Dog!" will show up, and the state is in TRIPPED. In that case, go to the next section to know how to reset Watch Dog. |
=== Check if all of VIS Guardians are at ALIGNED state === Look at Guardian Overview {{attachment:VIS guardian.png||height="",width="880"}} OR you can see the VIS status on the Monitor {{attachment:VIS guardian 2.png||height="",width="680"}} * If the Guardian is at TRIPPED state, you should [[http://gwwiki.icrr.u-tokyo.ac.jp/JGWwiki/KAGRA/Commissioning/Phase1/Operation/ShiftManual#How_to_reset_Watch_Dogs|reset Watch Dogs (WDs)]], OR call operation shift members (contact person TBD). === Check the IO Guardian === {{attachment:IO guardian.png||height="",width="680"}} IO Guardian should at PROVIDING_STABLE_LIGHT state, if not call operation shift members '''ASAP!!!'''(contact person TBD). === Check the Green Laser status === * See if the shutter is on or not. If the background color is green, the shutter is ok/open (red means the shutter is closed). {{attachment:shutter.png||height="",width="680"}} * see if K1: ALS-X (Y)_ARM_INPUT_OUT is more than 0.7 {{attachment:0.7.png||height="",width="680"}} * Check if ALS_PLLX/ALS_PLLY Guardian is at PLL_LOCK state {{attachment:PLLXY1.png||height="",width="880"}} ------ == Control Room Overview == * IFO Monitor: shows the status of the Main Interferometer . {{attachment:IFO1.png||width="630"}} * CCD Monitor: . {{attachment:CCD.jpg||height="881"}} * DAQ/VIS status: . {{attachment:vis status.png||height="681"}} * PEM Monitor: Room temperature/ Vacuum pressure . {{attachment:Pem.jpg||width="630"}} * Time: show JST/UTC/GPS time . {{attachment:GPS t ime.jpg||width="430"}} |
For collaborator shifts
Operator shift table in JGW-M1910914
Some information for collaborator shifts in JGW-M1809380
Collaboration shift routine tasks
- When FPMI cannot keep locked state for over 10 minutes or cannot got to lock state
---> call operator shift members
contact person (operator shift) on the day is listed with PHONE NUMBER around white board in the control room or see the link JGW-M1910914 (no phone number in this list)
Write "Log book" (JGW-E1911124) on the desk in the control room.
- Check Guardian status for 5 items, LSC, VIS, IO, Green laser and ALS. Instruction is in below.
- Put check mark every 2 hours.
- Write down everything you noticed.
- Example: lock lost, earthquake, somebody entered mine etc.
Please write klog: http://klog.icrr.u-tokyo.ac.jp/osl/ before you leave control room.
Writing klog is very important. This is only one tool which can show the status in the control room to outside.
- Account name and password are shown on the white board in the control room.
Leave message on "Takeover note" (JGW-T1605032) on the desk in the control room if you have something to tell to the next shift.
- Improve this wiki page if you had something you did not understand well and you found what it is.
- Search "KAGRA wiki" in google and access to KAGRA top page.
- Go to ERun top page on the second line of KAGRA Top page, and go to "Collaborator shift manuals". That page is this manual.
- Login KAGRA wiki, and press "Edit" button around the top left.
- Account name and password are shown on the white board in the control room.
1. Interferometer locking status screen
- Please check the interferometer locking screen first. If the status is not "LOCKED", something might happen.
- If FPMI cannot keep "LOCKED" state for over 10 minutes or cannot got back to "LOCKED" state, please contact operator shift.
2. Accessing to the guardian screen
- On the desktop, you can click the sitemap.
- In the sitemap, you can click on the link for the guardian overview screen.
Check list of the interferometer
Check if the LSC_LOCK Guardian at OBSERVATION state
Check if all of VIS Guardians are at ALIGNED state
Look at Guardian Overview
OR you can see the VIS status on the Monitor
If the Guardian is at TRIPPED state, you should reset Watch Dogs (WDs), OR call operation shift members (contact person TBD).
Check the IO Guardian
IO Guardian should at PROVIDING_STABLE_LIGHT state, if not call operation shift members ASAP!!!(contact person TBD).
Check the Green Laser status
- See if the shutter is on or not. If the background color is green, the shutter is ok/open (red means the shutter is closed).
- see if K1: ALS-X (Y)_ARM_INPUT_OUT is more than 0.7
- Check if ALS_PLLX/ALS_PLLY Guardian is at PLL_LOCK state
Control Room Overview
- IFO Monitor: shows the status of the Main Interferometer
- CCD Monitor:
- DAQ/VIS status:
- PEM Monitor: Room temperature/ Vacuum pressure
- Time: show JST/UTC/GPS time