Differences between revisions 37 and 111 (spanning 74 versions)
Revision 37 as of 2019-12-16 10:40:03
Size: 3643
Editor: guiguo.ge
Comment:
Revision 111 as of 2019-12-17 15:46:31
Size: 4601
Comment:
Deletions are marked like this. Additions are marked like this.
Line 1: Line 1:
= For collaborator shifts =
Line 2: Line 4:
    * When FPMI cannot keep lock state for over 10 minutes or cannot got to lock state ---> call operation shift members (contact person TBD).  * Operator shift table in [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=10914|JGW-M1910914]]
 * Some information for collaborator shifts in [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=9380|JGW-M1809380]]
Line 5: Line 7:
 * Collaboration shift routine tasks ------
==
Collaboration shift routine tasks ==
Line 7: Line 10:
 . <<TableOfContents(2)>>  1. Write "Log book" ([[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=11124|JGW-E1911124]]) on the desk in the control room.
  * Check Guardian status for 5 items, LSC, VIS, IO, Green laser and ALS. Instruction is in below.
  * Put check mark every 2 hours.
  * Write down everything you noticed.
   * Example: lock lost, earthquake, somebody entered mine etc.
 * When FPMI cannot keep lock state for over 10 minutes or cannot got to lock state
  ---> call operation shift members
   * contact person on the day is listed with '''PHONE NUMBER''' around white board in the control room or see the link [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=10914|JGW-M1910914]] (no phone number in this list)
 * Please write [[http://klog.icrr.u-tokyo.ac.jp/osl/|klog]]: [[http://klog.icrr.u-tokyo.ac.jp/osl/]] before you leave control room.
  * Writing [[http://klog.icrr.u-tokyo.ac.jp/osl/|klog]] is very important. This is only one tool which can show the status in the control room to outside.
  * Account name and password are shown on the white board in the control room.
 * Leave message on "Takeover note" ([[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=5032|JGW-T1605032]]) on the desk in the control room if you have something to tell to the next shift.
 * Improve this wiki page if you had something you did not understand well and you found what it is.
  1. Search "KAGRA wiki" in google and access to KAGRA top page.
  * Go to ERun top page on the second line of KAGRA Top page, and go to "Collaborator shift manuals". That page is this manual.
  * Login KAGRA wiki, and press "Edit" button around the top left.
   * Account name and password are shown on the white board in the control room.
Line 9: Line 28:
== Control Room Overview ==
* IFO Monitor: shows the status of the Main Interferometer
 . {{attachment:IFO1.png||width="630"}}
* CCD Monitor:
 . {{attachment:ccd monitor.png||height="681"}}
* DAQ/VIS status:
 . {{attachment:vis status.png||height="681"}}
* PEM Monitor: Room temperature/ Vacuum pressure
 . {{attachment:Pem.jpg||width="630"}}
* Time: show JST/UTC/GPS time
 . {{attachment:GPS t ime.jpg||width="430"}}
------
------

=== Interferometer locking status screen ===
 * Please check the interferometer locking screen first. If the status is not "LOCKED", something might happen.
  * If you are not sure, please contact operator shift.

 {{attachment:IFOstatus_s.png||width="800"}}
Line 22: Line 38:
== How to use Guardian ==
Line 24: Line 39:
 . In the desktop, you can click on the sitemap.
 . {{attachment:111.png||width="330"}}
 . {{attachment:112.png||width="430"}}
 . On the desktop, you can click the sitemap.

 . {{attachment:112.png||width="630"}}
Line 28: Line 43:
 . {{attachment:114.png||width="730"}}
 . {{attachment:guardian_explanation.png||width=""}}
=== Knowing the current state and requested state ===
 . {{attachment:guardian_howto4.png||height="281",width="434"}}
 . {{attachment:116.png||width="730"}}
Line 33: Line 45:
=== How to request a state ===
 . Click on the gray bar in the middle.<<BR>> {{attachment:guardian_howto.png||height="298",width="433"}} <<BR>> Then, choose the desired state.<<BR>> {{attachment:guardian_howto2.png||height="299",width="434"}}
Line 36: Line 46:
== Check list of the interferometer ==
 . Look at the Guardian overview, check if all of VIS Guardians are in ALIGNED state.
= Check list of the interferometer =
=== Check if the LSC_LOCK Guardian at OBSERVATION state ===
{{attachment:LCSLOCK.png||height="",width="880"}}

=== Check if all of VIS Guardians are at ALIGNED state ===
Look at Guardian Overview
Line 42: Line 56:
*If the Guardian is in TRIPPED state, you should [[http://gwwiki.icrr.u-tokyo.ac.jp/JGWwiki/KAGRA/Commissioning/Phase1/Operation/ShiftManual#How_to_reset_Watch_Dogs|reset Watch Dogs (WDs)]], OR call operation shift members.  * If the Guardian is at TRIPPED state, you should [[http://gwwiki.icrr.u-tokyo.ac.jp/JGWwiki/KAGRA/Commissioning/Phase1/Operation/ShiftManual#How_to_reset_Watch_Dogs|reset Watch Dogs (WDs)]], OR call operation shift members (contact person TBD).

=== Check the IO Guardian ===
{{attachment:IO guardian.png||height="",width="680"}}

IO Guardian should at PROVIDING_STABLE_LIGHT state, if not call operation shift members '''ASAP!!!'''(contact person TBD).

=== Check the Green Laser status ===
 * See if the shutter is on or not. If the background color is green, the shutter is ok/open (red means the shutter is closed).

{{attachment:shutter.png||height="",width="680"}}
Line 45: Line 69:
 * see if K1: ALS-X (Y)_ARM_INPUT_OUT is more than 0.7
Line 46: Line 71:
<<BR>>If "OFF", check the guardian overview screen<<BR>> {{attachment:guardian_howto3.png||height="281",width="434"}} <<BR>>Check the state of LSC_MICH. First check if the request state of LSC_MICH is OPERATION. If it is not, request OPERATION.<<BR>> {{attachment:guardian_howto4.png||height="281",width="434"}}
 . If the state is ''READY, ENGAGE_SERVO, ENGAGE_BOOST, MICH_LOCKED, CALIBRATION_INJECTION'', or ''ACTUATORCAL_INJECTION'', the interferometer is now on the way to be OPERATION state. It will be ready soon. <<BR>> /!\ ''' If it does not enter OPERATION state in a few mins. Call the interferometer experts.'''<<BR>> Check the status of ''IMC_LOCK, VIS_BS, VIS_PR2, VIS_PR3''. (Note that ''VIS_PRM'' is not used for now, so just ignore it) <<BR>>For IMC_LOCK, every thing should be green and IMC should be back automatically. <<BR>> {{attachment:IMC_guardian.png||height="293",width="453"}} <<BR>> For example, this is how the IMC_LOCK guardian should normally look like.<<BR>> {{attachment:IMC_guardian_status.png||height="281",width="407"}} <<BR>> /!\ '''If it does not come back in ~ 10 mins, call interferometer/IOO experts.'''<<BR>> For VIS_PR2 and VIS_BS, the state should be ALIGNED. If inot, a notification "please reset Watch Dog!" will show up, and the state is in TRIPPED. In that case, go to the next section to know how to reset Watch Dog. <<BR>> For VIS_PR3, the state should be DAMPED. If it is not, a notification "please reset Watch Dog!" will show up, and the state is in TRIPPED. In that case, go to the next section to know how to reset Watch Dog.
{{attachment:0.7.png||height="",width="680"}}

 * Check if ALS_PLLX/ALS_PLLY Guardian is at PLL_LOCK state

{{attachment:PLLXY1.png||height="",width="880"}}


------
== Control Room Overview ==
 * IFO Monitor: shows the status of the Main Interferometer
 . {{attachment:IFO1.png||width="630"}}
 * CCD Monitor:
 . {{attachment:CCD.jpg||height="881"}}
 * DAQ/VIS status:
 . {{attachment:vis status.png||height="681"}}
 * PEM Monitor: Room temperature/ Vacuum pressure
 . {{attachment:Pem.jpg||width="630"}}
 * Time: show JST/UTC/GPS time
 . {{attachment:GPS t ime.jpg||width="430"}}

For collaborator shifts


Collaboration shift routine tasks

  1. Write "Log book" (JGW-E1911124) on the desk in the control room.

    • Check Guardian status for 5 items, LSC, VIS, IO, Green laser and ALS. Instruction is in below.
    • Put check mark every 2 hours.
    • Write down everything you noticed.
      • Example: lock lost, earthquake, somebody entered mine etc.
  2. When FPMI cannot keep lock state for over 10 minutes or cannot got to lock state
    • ---> call operation shift members

      • contact person on the day is listed with PHONE NUMBER around white board in the control room or see the link JGW-M1910914 (no phone number in this list)

  3. Please write klog: http://klog.icrr.u-tokyo.ac.jp/osl/ before you leave control room.

    • Writing klog is very important. This is only one tool which can show the status in the control room to outside.

    • Account name and password are shown on the white board in the control room.
  4. Leave message on "Takeover note" (JGW-T1605032) on the desk in the control room if you have something to tell to the next shift.

  5. Improve this wiki page if you had something you did not understand well and you found what it is.
    1. Search "KAGRA wiki" in google and access to KAGRA top page.
    2. Go to ERun top page on the second line of KAGRA Top page, and go to "Collaborator shift manuals". That page is this manual.
    3. Login KAGRA wiki, and press "Edit" button around the top left.
      • Account name and password are shown on the white board in the control room.



Interferometer locking status screen

  • Please check the interferometer locking screen first. If the status is not "LOCKED", something might happen.
    • If you are not sure, please contact operator shift.

    IFOstatus_s.png

Accessing to the guardian screen

  • On the desktop, you can click the sitemap.
  • 112.png

  • In the sitemap, you can click on the link for the guardian overview screen.
  • 116.png

Check list of the interferometer

Check if the LSC_LOCK Guardian at OBSERVATION state

LCSLOCK.png

Check if all of VIS Guardians are at ALIGNED state

Look at Guardian Overview

  • VIS guardian.png

OR you can see the VIS status on the Monitor

  • VIS guardian 2.png

  • If the Guardian is at TRIPPED state, you should reset Watch Dogs (WDs), OR call operation shift members (contact person TBD).

Check the IO Guardian

IO guardian.png

IO Guardian should at PROVIDING_STABLE_LIGHT state, if not call operation shift members ASAP!!!(contact person TBD).

Check the Green Laser status

  • See if the shutter is on or not. If the background color is green, the shutter is ok/open (red means the shutter is closed).

shutter.png

  • see if K1: ALS-X (Y)_ARM_INPUT_OUT is more than 0.7

0.7.png

  • Check if ALS_PLLX/ALS_PLLY Guardian is at PLL_LOCK state

PLLXY1.png


Control Room Overview

  • IFO Monitor: shows the status of the Main Interferometer
  • IFO1.png

  • CCD Monitor:
  • CCD.jpg

  • DAQ/VIS status:
  • vis status.png

  • PEM Monitor: Room temperature/ Vacuum pressure
  • Pem.jpg

  • Time: show JST/UTC/GPS time
  • GPS t ime.jpg

KAGRA/EngineeringRun/ER191217_24/Shift (last edited 2020-04-07 12:03:16 by OsamuMiyakawa)