Differences between revisions 42 and 46 (spanning 4 versions)
Revision 42 as of 2019-12-16 11:24:53
Size: 3991
Editor: miyoki
Comment:
Revision 46 as of 2019-12-16 11:29:46
Size: 4511
Editor: guiguo.ge
Comment:
Deletions are marked like this. Additions are marked like this.
Line 2: Line 2:

---- /!\ '''Edit conflict - other version:''' ----
Line 3: Line 5:

---- /!\ '''Edit conflict - your version:''' ----

---- /!\ '''End of edit conflict''' ----
Line 11: Line 17:
* IFO Monitor: shows the status of the Main Interferometer  * IFO Monitor: shows the status of the Main Interferometer
Line 13: Line 19:
* CCD Monitor:  * CCD Monitor:
Line 15: Line 21:
* DAQ/VIS status:  * DAQ/VIS status:
Line 17: Line 23:
* PEM Monitor: Room temperature/ Vacuum pressure  * PEM Monitor: Room temperature/ Vacuum pressure
Line 19: Line 25:
* Time: show JST/UTC/GPS time  * Time: show JST/UTC/GPS time
Line 43: Line 49:
*If the Guardian is in TRIPPED state, you should [[http://gwwiki.icrr.u-tokyo.ac.jp/JGWwiki/KAGRA/Commissioning/Phase1/Operation/ShiftManual#How_to_reset_Watch_Dogs|reset Watch Dogs (WDs)]],  * If the Guardian is in TRIPPED state, you should [[http://gwwiki.icrr.u-tokyo.ac.jp/JGWwiki/KAGRA/Commissioning/Phase1/Operation/ShiftManual#How_to_reset_Watch_Dogs|reset Watch Dogs (WDs)]],
Line 52: Line 58:
==== Check the Green Laser status ====
 * see if the shutter is on or not

{{attachment:shutter.png||height="",width="680"}}

 * see if K1: ALS-X (Y)_ARM_INPUT_OUT is more than 0.7

{{attachment:0.7.png||height="",width="680"}}

 * Check if ALS_PLLX/ALS_PLLY Guardian is on PLL_LOCK state

{{attachment:PLLXY1.png||height="",width="680"}}



/!\ Edit conflict - other version:



/!\ Edit conflict - your version:



/!\ End of edit conflict


Control Room Overview

How to use Guardian

Accessing to the guardian screen

Knowing the current state and requested state

How to request a state

Check list of the interferometer

Look at the Guardian overview, check if all of VIS Guardians are in ALIGNED state

OR you can see the VIS status on the Monitor

OR call operation shift members (contact person TBD).

Check the IO Guardian

IO guardian.png

IO Guardian should in PROVIDING_STABLE_LIGHT state, if not call operation shift members ASAP!!!(contact person TBD).

Check the Green Laser status

shutter.png

0.7.png

PLLXY1.png


If "OFF", check the guardian overview screen
guardian_howto3.png
Check the state of LSC_MICH. First check if the request state of LSC_MICH is OPERATION. If it is not, request OPERATION.
guardian_howto4.png

KAGRA/EngineeringRun/ER191217_24/Shift (last edited 2020-04-07 12:03:16 by OsamuMiyakawa)