Differences between revisions 48 and 72 (spanning 24 versions)
Revision 48 as of 2019-12-16 11:31:34
Size: 4469
Editor: guiguo.ge
Comment:
Revision 72 as of 2019-12-16 16:55:09
Size: 3242
Editor: guiguo.ge
Comment:
Deletions are marked like this. Additions are marked like this.
Line 16: Line 16:
== Control Room Overview == = Control Room Overview =
Line 20: Line 20:
 . {{attachment:ccd monitor.png||height="681"}}  . {{attachment:CCD.jpg||height="881"}}
Line 29: Line 29:
== How to use Guardian ==
= How to check Guardian =
[[http://gwwiki.icrr.u-tokyo.ac.jp/JGWwiki/KAGRA/Commissioning/Phase1/Operation/ShiftManual#How_to_reset_Watch_Dogs|how to use Guardian]]
Line 31: Line 33:
 . In the desktop, you can click on the sitemap.  . On the desktop, you can click the sitemap.
Line 34: Line 37:
 . {{attachment:114.png||width="730"}}  . {{attachment:116.png||width="730"}}
 . Meaning of the background color
Line 42: Line 46:
== Check list of the interferometer ==
==== Look at the
Guardian overview, check if all of VIS Guardians are in ALIGNED state ====
= Check list of the interferometer =
=== Check if the LSC_LOCK
Guardian at OBSERVATION state ===
{{attachment:LCSLOCK.png||height="",
width="880"}}

=== C
heck if all of VIS Guardians are at ALIGNED state ===
Look at Guardian Overview
Line 48: Line 56:
 * If the Guardian is in TRIPPED state, you should [[http://gwwiki.icrr.u-tokyo.ac.jp/JGWwiki/KAGRA/Commissioning/Phase1/Operation/ShiftManual#How_to_reset_Watch_Dogs|reset Watch Dogs (WDs)]], OR call operation shift members (contact person TBD).  * If the Guardian is at TRIPPED state, you should [[http://gwwiki.icrr.u-tokyo.ac.jp/JGWwiki/KAGRA/Commissioning/Phase1/Operation/ShiftManual#How_to_reset_Watch_Dogs|reset Watch Dogs (WDs)]], OR call operation shift members (contact person TBD).
Line 50: Line 58:
==== Check the IO Guardian ====
=== Check the IO Guardian ===
Line 54: Line 61:
IO Guardian should in PROVIDING_STABLE_LIGHT state, if not call operation shift members '''ASAP!!!'''(contact person TBD). IO Guardian should at PROVIDING_STABLE_LIGHT state, if not call operation shift members '''ASAP!!!'''(contact person TBD).
Line 56: Line 63:
==== Check the Green Laser status ====
 * see if the shutter is on or not
=== Check the Green Laser status ===
 * See if the shutter is on or not. If the background color is green, the shutter is ok/open (red means the shutter is closed).
Line 60: Line 67:
Line 65: Line 73:
 * Check if ALS_PLLX/ALS_PLLY Guardian is on PLL_LOCK state  * Check if ALS_PLLX/ALS_PLLY Guardian is at PLL_LOCK state
Line 67: Line 75:
{{attachment:PLLXY1.png||height="",width="680"}}



<<BR>>If "OFF", check the guardian overview screen<<BR>> {{attachment:guardian_howto3.png||height="281",width="434"}} <<BR>>Check the state of LSC_MICH. First check if the request state of LSC_MICH is OPERATION. If it is not, request OPERATION.<<BR>> {{attachment:guardian_howto4.png||height="281",width="434"}}
 . If the state is ''READY, ENGAGE_SERVO, ENGAGE_BOOST, MICH_LOCKED, CALIBRATION_INJECTION'', or ''ACTUATORCAL_INJECTION'', the interferometer is now on the way to be OPERATION state. It will be ready soon. <<BR>> /!\ ''' If it does not enter OPERATION state in a few mins. Call the interferometer experts.'''<<BR>> Check the status of ''IMC_LOCK, VIS_BS, VIS_PR2, VIS_PR3''. (Note that ''VIS_PRM'' is not used for now, so just ignore it) <<BR>>For IMC_LOCK, every thing should be green and IMC should be back automatically. <<BR>> {{attachment:IMC_guardian.png||height="293",width="453"}} <<BR>> For example, this is how the IMC_LOCK guardian should normally look like.<<BR>> {{attachment:IMC_guardian_status.png||height="281",width="407"}} <<BR>> /!\ '''If it does not come back in ~ 10 mins, call interferometer/IOO experts.'''<<BR>> For VIS_PR2 and VIS_BS, the state should be ALIGNED. If inot, a notification "please reset Watch Dog!" will show up, and the state is in TRIPPED. In that case, go to the next section to know how to reset Watch Dog. <<BR>> For VIS_PR3, the state should be DAMPED. If it is not, a notification "please reset Watch Dog!" will show up, and the state is in TRIPPED. In that case, go to the next section to know how to reset Watch Dog.
{{attachment:PLLXY1.png||height="",width="880"}}


/!\ Edit conflict - other version:



/!\ Edit conflict - your version:



/!\ End of edit conflict


Control Room Overview

  • IFO Monitor: shows the status of the Main Interferometer
  • IFO1.png

  • CCD Monitor:
  • CCD.jpg

  • DAQ/VIS status:
  • vis status.png

  • PEM Monitor: Room temperature/ Vacuum pressure
  • Pem.jpg

  • Time: show JST/UTC/GPS time
  • GPS t ime.jpg

How to check Guardian

how to use Guardian

Accessing to the guardian screen

  • On the desktop, you can click the sitemap.
  • 112.png

  • In the sitemap, you can click on the link for the guardian overview screen.
  • 116.png

  • Meaning of the background color
  • guardian_explanation.png

Knowing the current state and requested state

  • guardian_howto4.png

How to request a state

  • Click on the gray bar in the middle.
    guardian_howto.png
    Then, choose the desired state.
    guardian_howto2.png

Check list of the interferometer

Check if the LSC_LOCK Guardian at OBSERVATION state

LCSLOCK.png

Check if all of VIS Guardians are at ALIGNED state

Look at Guardian Overview

  • VIS guardian.png

OR you can see the VIS status on the Monitor

  • VIS guardian 2.png

  • If the Guardian is at TRIPPED state, you should reset Watch Dogs (WDs), OR call operation shift members (contact person TBD).

Check the IO Guardian

IO guardian.png

IO Guardian should at PROVIDING_STABLE_LIGHT state, if not call operation shift members ASAP!!!(contact person TBD).

Check the Green Laser status

  • See if the shutter is on or not. If the background color is green, the shutter is ok/open (red means the shutter is closed).

shutter.png

  • see if K1: ALS-X (Y)_ARM_INPUT_OUT is more than 0.7

0.7.png

  • Check if ALS_PLLX/ALS_PLLY Guardian is at PLL_LOCK state

PLLXY1.png

KAGRA/EngineeringRun/ER191217_24/Shift (last edited 2020-04-07 12:03:16 by OsamuMiyakawa)