 * When FPMI cannot keep lock state for over 10 minutes or cannot got to lock state ---> call operation shift members (contact person TBD).
Line 3: Line 13:
  *
  *
  *
 * When FPMI cannot keep lock state for over 10 minutes or cannot got to lock state ---> call operation shift members.
Line 12: Line 17:
 . {{attachment:image1.jpeg||width="1000"}} * IFO Monitor: shows the status of the Main Interferometer
 . {{attachment:IFO1.png||width="630"}}
* CCD Monitor:
 . {{attachment:ccd monitor.png||height="681"}}
* DAQ/VIS status:
 . {{attachment:vis status.png||height="681"}}
* PEM Monitor: Room temperature/ Vacuum pressure
 . {{attachment:Pem.jpg||width="630"}}
* Time: show JST/UTC/GPS time
 . {{attachment:GPS t ime.jpg||width="430"}}
Line 14: Line 28:
 . {{attachment:IMG_4929.jpg||width="430"}}
Line 18: Line 31:
 . In the desktop, you can click on the sitemap.
 . {{attachment:111.png||width="330"}}
 . {{attachment:112.png||width="430"}}
Line 19: Line 35:
 {{attachment:sitemap_guardian.png||height="172",width="430"}} <<BR>> It pops up the following screen, <<BR>> {{attachment:guardian_howto3.png||height="281",width="434"}}
 . {{attachment:114.png||width="730"}}
. {{attachment:guardian_explanation.png||width=""}}
Line 27: Line 43:
== How to know the status of the interferometer ==
 . Look at one of the TV monitor in the control room. If "ON", it is in OPERATION mode.
 {{attachment:obs_state.png||height="233",width="465"}} <<BR>>If "OFF", check the guardian overview screen<<BR>> {{attachment:guardian_howto3.png||height="281",width="434"}} <<BR>>Check the state of LSC_MICH. First check if the request state of LSC_MICH is OPERATION. If it is not, request OPERATION.<<BR>> {{attachment:guardian_howto4.png||height="281",width="434"}}
== Check list of the interferometer ==
==== Look at the Guardian overview, check if all of VIS Guardians are in ALIGNED state ====
 {{attachment:VIS guardian.png||height="",width="880"}}
 
OR you can see the VIS status on the Monitor
 {{attachment:VIS guardian 2.png||height="",width="680"}}
*If the Guardian is in TRIPPED state, you should [[http://gwwiki.icrr.u-tokyo.ac.jp/JGWwiki/KAGRA/Commissioning/Phase1/Operation/ShiftManual#How_to_reset_Watch_Dogs|reset Watch Dogs (WDs)]],
OR call operation shift members (contact person TBD).

==== Check the IO Guardian ====

{{attachment:IO guardian.png||height="",width="680"}}

IO Guardian should in PROVIDING_STABLE_LIGHT state, if not call operation shift members '''ASAP!!!'''(contact person TBD).

==== Check the Green Laser status ====
 * see if the shutter is on or not

{{attachment:shutter.png||height="",width="680"}}

 * see if K1: ALS-X (Y)_ARM_INPUT_OUT is more than 0.7

{{attachment:0.7.png||height="",width="680"}}

 * Check if ALS_PLLX/ALS_PLLY Guardian is on PLL_LOCK state

{{attachment:PLLXY1.png||height="",width="680"}}



<<BR>>If "OFF", check the guardian overview screen<<BR>> {{attachment:guardian_howto3.png||height="281",width="434"}} <<BR>>Check the state of LSC_MICH. First check if the request state of LSC_MICH is OPERATION. If it is not, request OPERATION.<<BR>> {{attachment:guardian_howto4.png||height="281",width="434"}}
Line 31: Line 75:

== How to reset Watch Dogs ==
 0. Request LSC_MICH to be READY by Guardian.

 0. Open Sitemap (from Terminal, type "mk" and press return).

 0. Click VIS

 0. Click the suspension of which you want to reset Watch Dog
 {{attachment:VISALL.png||width="407"}} <<BR>>

 0. Go to PRs case or BS case

=== PRs case ===
 4. Request SAFE by Guardian

 4. Open "DETAILS" at bottom right,
 {{attachment:PRTOP.png||width="300"}} <<BR>>
  . and you will find PRs overview screen
 {{attachment:PR.png||width="800"}} <<BR>>

 4. Click WATCHDOG
  . If something is red, press here to reset.
 {{attachment:PRWD.png||width="400"}} <<BR>>

 4. Click DACKILL (see the picture above, PRs overview sceen)
  . If it is not green, press reset.
 {{attachment:DACKILL.png||width="200"}} <<BR>>

 4. Click Coil Driver WD (picture above, PRs overview sceen) Check if everything is green. If there are red signs, push corresponding WD Pulse ON button and then OFF button
 {{attachment:PR_CDWD.png||width="800"}} <<BR>>

 4. Request DAMPED. For PR2, ~ 10 seconds after the state becomes DAMPED, request ALIENED.

 4. ~ 10 seconds after the suspension gets in a nominal state, request LSC_MICH to be OPERATION.

=== BS case ===
 4. Request SAFE by Guardian

 4. Open "Payload" at bottom center,
 {{attachment:BSTOP.png||width="250"}} <<BR>>
  . and you will find BS payload overview screen
 {{attachment:BSpayload.png||width="800"}} <<BR>>

 4. Click WATCHDOG If something is red, press here to reset.
 {{attachment:PRWD.png||width="400"}} <<BR>>

 4. Click DACKILL (see the picture above for BS overview screen) If it is not green, press reset.
 {{attachment:DACKILL.png||width="200"}} <<BR>>

 4. Click Coil Driver WD (see the picture above for BS overview screen) Check if everything is green. If there are red signs, push corresponding WD Pulse ON button and then OFF button
 {{attachment:PR_CDWD.png||width="800"}} <<BR>>

 4. Request DAMPED. For PR2, ~ 10 seconds after the state becomes DAMPED, request ALIENED.

 4. ~ 10 seconds after the suspension gets in a nominal state, request LSC_MICH to be OPERATION.


/!\ Edit conflict - other version:



/!\ Edit conflict - your version:



/!\ End of edit conflict


Control Room Overview

* IFO Monitor: shows the status of the Main Interferometer

* CCD Monitor:

* DAQ/VIS status:

* PEM Monitor: Room temperature/ Vacuum pressure

* Time: show JST/UTC/GPS time

How to use Guardian

Accessing to the guardian screen

Knowing the current state and requested state

How to request a state

Check list of the interferometer

Look at the Guardian overview, check if all of VIS Guardians are in ALIGNED state

OR you can see the VIS status on the Monitor

*If the Guardian is in TRIPPED state, you should reset Watch Dogs (WDs), OR call operation shift members (contact person TBD).

Check the IO Guardian

IO guardian.png

IO Guardian should in PROVIDING_STABLE_LIGHT state, if not call operation shift members ASAP!!!(contact person TBD).

Check the Green Laser status

shutter.png

0.7.png

PLLXY1.png


If "OFF", check the guardian overview screen
guardian_howto3.png
Check the state of LSC_MICH. First check if the request state of LSC_MICH is OPERATION. If it is not, request OPERATION.
guardian_howto4.png