Differences between revisions 55 and 69 (spanning 14 versions)
Revision 55 as of 2019-12-16 15:54:47
Size: 2992
Editor: guiguo.ge
Comment:
Revision 69 as of 2019-12-16 16:50:45
Size: 3262
Editor: guiguo.ge
Comment:
Deletions are marked like this. Additions are marked like this.
Line 16: Line 16:
== Control Room Overview == = Control Room Overview =
Line 29: Line 29:
== How to use Guardian ==
= How to check Guardian =
[[http://gwwiki.icrr.u-tokyo.ac.jp/JGWwiki/KAGRA/Commissioning/Phase1/Operation/ShiftManual#How_to_reset_Watch_Dogs|how to use Guardian]]
Line 31: Line 33:
 . In the desktop, you can click on the sitemap.  . On the desktop, you can click the sitemap.
Line 34: Line 37:
 . {{attachment:114.png||width="730"}}  . {{attachment:116.png||width="730"}}
 . Meaning of the background color
Line 43: Line 46:
== Check list of the interferometer ==
==== Check if the LSC_LOCK Guardian at OBSERVATION state ====
= Check list of the interferometer =
=== Check if the LSC_LOCK Guardian at OBSERVATION state ===
Line 47: Line 50:
==== Look at the Guardian overview, check if all of VIS Guardians are in ALIGNED state ==== === Check if all of VIS Guardians are at ALIGNED state ===
Look at Guardian Overview
Line 52: Line 56:
 * If the Guardian is in TRIPPED state, you should [[http://gwwiki.icrr.u-tokyo.ac.jp/JGWwiki/KAGRA/Commissioning/Phase1/Operation/ShiftManual#How_to_reset_Watch_Dogs|reset Watch Dogs (WDs)]], OR call operation shift members (contact person TBD).  * If the Guardian is at TRIPPED state, you should [[http://gwwiki.icrr.u-tokyo.ac.jp/JGWwiki/KAGRA/Commissioning/Phase1/Operation/ShiftManual#How_to_reset_Watch_Dogs|reset Watch Dogs (WDs)]], OR call operation shift members (contact person TBD).
Line 54: Line 58:
==== Check the IO Guardian ====
=== Check the IO Guardian ===
Line 58: Line 61:
IO Guardian should in PROVIDING_STABLE_LIGHT state, if not call operation shift members '''ASAP!!!'''(contact person TBD). IO Guardian should at PROVIDING_STABLE_LIGHT state, if not call operation shift members '''ASAP!!!'''(contact person TBD).
Line 60: Line 63:
==== Check the Green Laser status ==== === Check the Green Laser status ===
Line 64: Line 67:

If the background color is green, the shutter is open.
If the background color is red, the shutter is closed.
Line 69: Line 75:
 * Check if ALS_PLLX/ALS_PLLY Guardian is on PLL_LOCK state  * Check if ALS_PLLX/ALS_PLLY Guardian is at PLL_LOCK state


/!\ Edit conflict - other version:



/!\ Edit conflict - your version:



/!\ End of edit conflict


Control Room Overview

  • IFO Monitor: shows the status of the Main Interferometer
  • IFO1.png

  • CCD Monitor:
  • CCD.jpg

  • DAQ/VIS status:
  • vis status.png

  • PEM Monitor: Room temperature/ Vacuum pressure
  • Pem.jpg

  • Time: show JST/UTC/GPS time
  • GPS t ime.jpg

How to check Guardian

how to use Guardian

Accessing to the guardian screen

  • On the desktop, you can click the sitemap.
  • 112.png

  • In the sitemap, you can click on the link for the guardian overview screen.
  • 116.png

  • Meaning of the background color
  • guardian_explanation.png

Knowing the current state and requested state

  • guardian_howto4.png

How to request a state

  • Click on the gray bar in the middle.
    guardian_howto.png
    Then, choose the desired state.
    guardian_howto2.png

Check list of the interferometer

Check if the LSC_LOCK Guardian at OBSERVATION state

LCSLOCK.png

Check if all of VIS Guardians are at ALIGNED state

Look at Guardian Overview

  • VIS guardian.png

OR you can see the VIS status on the Monitor

  • VIS guardian 2.png

  • If the Guardian is at TRIPPED state, you should reset Watch Dogs (WDs), OR call operation shift members (contact person TBD).

Check the IO Guardian

IO guardian.png

IO Guardian should at PROVIDING_STABLE_LIGHT state, if not call operation shift members ASAP!!!(contact person TBD).

Check the Green Laser status

  • see if the shutter is on or not

shutter.png

If the background color is green, the shutter is open. If the background color is red, the shutter is closed.

  • see if K1: ALS-X (Y)_ARM_INPUT_OUT is more than 0.7

0.7.png

  • Check if ALS_PLLX/ALS_PLLY Guardian is at PLL_LOCK state

PLLXY1.png