= How to use Guardian = | = How to check Guardian = [[http://gwwiki.icrr.u-tokyo.ac.jp/JGWwiki/KAGRA/Commissioning/Phase1/Operation/ShiftManual#How_to_reset_Watch_Dogs|how to use Guardian]] |
Line 31: | Line 33: |
. In the desktop, you can click on the sitemap. | . On the desktop, you can click the sitemap. ---- /!\ '''End of edit conflict''' ---- |
Line 34: | Line 38: |
. {{attachment:114.png||width="730"}} | . {{attachment:116.png||width="730"}} . Meaning of the background color |
Line 47: | Line 51: |
=== Look at the Guardian overview, check if all of VIS Guardians are in ALIGNED state === | === Check if all of VIS Guardians are in ALIGNED state === Look at Guardian Overview |
Line 55: | Line 60: |
Edit conflict - other version:
Edit conflict - your version:
End of edit conflict
When FPMI cannot keep lock state for over 10 minutes or cannot got to lock state ---> call operation shift members (contact person TBD).
- Collaboration shift routine tasks
Control Room Overview
- IFO Monitor: shows the status of the Main Interferometer
- CCD Monitor:
- DAQ/VIS status:
- PEM Monitor: Room temperature/ Vacuum pressure
- Time: show JST/UTC/GPS time
How to check Guardian
Accessing to the guardian screen
- On the desktop, you can click the sitemap.
End of edit conflict
- In the sitemap, you can click on the link for the guardian overview screen.
- Meaning of the background color
Knowing the current state and requested state
How to request a state
Click on the gray bar in the middle.
Then, choose the desired state.
Check list of the interferometer
Check if the LSC_LOCK Guardian at OBSERVATION state
Check if all of VIS Guardians are in ALIGNED state
Look at Guardian Overview
OR you can see the VIS status on the Monitor
If the Guardian is in TRIPPED state, you should reset Watch Dogs (WDs), OR call operation shift members (contact person TBD).
Check the IO Guardian
IO Guardian should in PROVIDING_STABLE_LIGHT state, if not call operation shift members ASAP!!!(contact person TBD).
Check the Green Laser status
- see if the shutter is on or not
- see if K1: ALS-X (Y)_ARM_INPUT_OUT is more than 0.7
- Check if ALS_PLLX/ALS_PLLY Guardian is on PLL_LOCK state