Differences between revisions 59 and 121 (spanning 62 versions)
Revision 59 as of 2019-12-16 16:14:50
Size: 2972
Editor: guiguo.ge
Comment:
Revision 121 as of 2019-12-17 16:10:19
Size: 4868
Comment:
Deletions are marked like this. Additions are marked like this.
Line 1: Line 1:
= For collaborator shifts =
Line 2: Line 4:
 * Operator shift table in [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=10914|JGW-M1910914]]
 * Some information for collaborator shifts in [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=9380|JGW-M1809380]]
Line 3: Line 7:
---- /!\ '''Edit conflict - other version:''' ----
 * [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=10914| Operator Shift]]
------
== Collaboration shift routine tasks ==
Line 6: Line 10:
---- /!\ '''Edit conflict - your version:''' ----  1. When FPMI cannot keep locked state for over 10 minutes or cannot got to lock state
  ---> call operator shift members
   * contact person (operator shift) on the day is listed with '''PHONE NUMBER''' around white board in the control room or see the link [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=10914|JGW-M1910914]] (no phone number in this list)
Line 8: Line 14:
---- /!\ '''End of edit conflict''' ----
  
 * When FPMI cannot keep lock state for over 10 minutes or cannot got to lock state ---> call operation shift members (contact person TBD).
 * Write "Log book" ([[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=11124|JGW-E1911124]]) on the desk in the control room.
  * Check Guardian status for 5 items, LSC, VIS, IO, Green laser and ALS. Instruction is in below.
  * Put check mark every 2 hours.
  * Write down everything you noticed.
   * Example: lock lost, earthquake, somebody entered mine etc.
 * Please write [[http://klog.icrr.u-tokyo.ac.jp/osl/|klog]]: [[http://klog.icrr.u-tokyo.ac.jp/osl/]] before you leave control room.
  * Writing [[http://klog.icrr.u-tokyo.ac.jp/osl/|klog]] is very important. This is only one tool which can show the status in the control room to outside.
  * Account name and password are shown on the white board in the control room.
 * Leave message on "Takeover note" ([[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=5032|JGW-T1605032]]) on the desk in the control room if you have something to tell to the next shift.
 * Improve this wiki page if you had something you did not understand well and you found what it is.
  1. Search "KAGRA wiki" in google and access to KAGRA top page.
  * Go to ERun top page on the second line of KAGRA Top page, and go to "Collaborator shift manuals". That page is this manual.
  * Login KAGRA wiki, and press "Edit" button around the top left.
   * Account name and password are shown on the white board in the control room.
Line 12: Line 29:
 * Collaboration shift routine tasks ------
------
Line 14: Line 32:
 . <<TableOfContents(2)>> == 1. Interferometer locking status screen ==
 * Please check the interferometer locking screen at the front monitor in the control room first. If the status is not "LOCKED", something might happen.
 * If FPMI cannot keep "LOCKED" state for over 10 minutes or cannot got back to "LOCKED" state, please contact operator shift.
Line 16: Line 36:
= Control Room Overview =
 * IFO Monitor: shows the status of the Main Interferometer
 . {{attachment:IFO1.png||width="630"}}
 * CCD Monitor:
 . {{attachment:CCD.jpg||height="881"}}
 * DAQ/VIS status:
 . {{attachment:vis status.png||height="681"}}
 * PEM Monitor: Room temperature/ Vacuum pressure
 . {{attachment:Pem.jpg||width="630"}}
 * Time: show JST/UTC/GPS time
 . {{attachment:GPS t ime.jpg||width="430"}}
 {{attachment:IFOstatus_s.png||width="800"}}
Line 29: Line 39:
= How to use Guardian =
=== Accessing to the guardian screen ===
 . In the desktop, you can click on the sitemap.
 . {{attachment:112.png||width="630"}}
 . In the sitemap, you can click on the link for the guardian overview screen.
 . {{attachment:114.png||width="730"}}
------
== 2. Check list of the interferometer ==
Line 36: Line 42:
 . {{attachment:guardian_explanation.png||width=""}}
=== Knowing the current state and requested state ===
 . {{attachment:guardian_howto4.png||height="281",width="434"}}
=== How to access to the guardian screen ===
 *On the desktop, you can click the sitemap.
Line 40: Line 45:
=== How to request a state ===
 . Click on the gray bar in the middle.<<BR>> {{attachment:guardian_howto.png||height="298",width="433"}} <<BR>> Then, choose the desired state.<<BR>> {{attachment:guardian_howto2.png||height="299",width="434"}}
 {{attachment:112.png||width="700"}}
Line 43: Line 47:
= Check list of the interferometer =
=== Check if the LSC_LOCK Guardian at OBSERVATION state ===
{{attachment:LCSLOCK.png||height="",width="880"}}
 *In the sitemap, you can click on the link for the guardian overview screen.
 {{attachment:116.png||width="800"}}
Line 47: Line 50:
=== Check if all of VIS Guardians are in ALIGNED state ===

=== 2-1. Check if the LSC_LOCK Guardian at OBSERVATION state ===

 * Please check the "LSC_LOCK" is in "OBSERVATION" mode. If not, please contact operator shift.
 {{attachment:116.png||width="800"}}


=== 2-2. Check if all of VIS Guardians are at ALIGNED state ===
Line 49: Line 60:
 {{attachment:VIS guardian.png||height="",width="880"}}  {{attachment:VIS guardian.png||height="",width="700"}}
Line 52: Line 63:
 {{attachment:VIS guardian 2.png||height="",width="680"}}
 * If the Guardian is in TRIPPED state, you should [[http://gwwiki.icrr.u-tokyo.ac.jp/JGWwiki/KAGRA/Commissioning/Phase1/Operation/ShiftManual#How_to_reset_Watch_Dogs|reset Watch Dogs (WDs)]], OR call operation shift members (contact person TBD).
 {{attachment:VIS guardian 2.png||height="",width="600"}}
 * If the Guardian is at TRIPPED state, you should [[http://gwwiki.icrr.u-tokyo.ac.jp/JGWwiki/KAGRA/Commissioning/Phase1/Operation/ShiftManual#How_to_reset_Watch_Dogs|reset Watch Dogs (WDs)]], OR call operation shift members (contact person TBD).
Line 55: Line 66:
=== Check the IO Guardian ===
{{attachment:IO guardian.png||height="",width="680"}}
=== 2-3. Check the IO Guardian ===
{{attachment:IO guardian.png||height="",width="800"}}
Line 58: Line 69:
IO Guardian should in PROVIDING_STABLE_LIGHT state, if not call operation shift members '''ASAP!!!'''(contact person TBD). IO Guardian should at PROVIDING_STABLE_LIGHT state, if not call operation shift members '''ASAP!!!'''(contact person TBD).
Line 60: Line 71:
=== Check the Green Laser status ===
 * see if the shutter is on or not
=== 2-4. Check the Green Laser status ===
 * See if the shutter is on or not. If the background color is green, the shutter is ok/open (red means the shutter is closed).
Line 63: Line 74:
{{attachment:shutter.png||height="",width="680"}} {{attachment:shutter.png||height="",width="800"}}
Line 69: Line 81:
 * Check if ALS_PLLX/ALS_PLLY Guardian is on PLL_LOCK state === 2-5. Check if ALS_PLLX/ALS_PLLY Guardian is at PLL_LOCK state ===
Line 72: Line 84:


------
== Control Room Overview ==
 * IFO Monitor: shows the status of the Main Interferometer
 . {{attachment:IFO1.png||width="800"}}
 * CCD Monitor:
 . {{attachment:CCD.jpg||height="1000"}}
 * DAQ/VIS status:
 . {{attachment:vis status.png||height="800"}}
 * PEM Monitor: Room temperature/ Vacuum pressure
 . {{attachment:Pem.jpg||width="800"}}
 * Time: show JST/UTC/GPS time
 . {{attachment:GPS t ime.jpg||width="800"}}

For collaborator shifts


Collaboration shift routine tasks

  1. When FPMI cannot keep locked state for over 10 minutes or cannot got to lock state
    • ---> call operator shift members

      • contact person (operator shift) on the day is listed with PHONE NUMBER around white board in the control room or see the link JGW-M1910914 (no phone number in this list)

  2. Write "Log book" (JGW-E1911124) on the desk in the control room.

    • Check Guardian status for 5 items, LSC, VIS, IO, Green laser and ALS. Instruction is in below.
    • Put check mark every 2 hours.
    • Write down everything you noticed.
      • Example: lock lost, earthquake, somebody entered mine etc.
  3. Please write klog: http://klog.icrr.u-tokyo.ac.jp/osl/ before you leave control room.

    • Writing klog is very important. This is only one tool which can show the status in the control room to outside.

    • Account name and password are shown on the white board in the control room.
  4. Leave message on "Takeover note" (JGW-T1605032) on the desk in the control room if you have something to tell to the next shift.

  5. Improve this wiki page if you had something you did not understand well and you found what it is.
    1. Search "KAGRA wiki" in google and access to KAGRA top page.
    2. Go to ERun top page on the second line of KAGRA Top page, and go to "Collaborator shift manuals". That page is this manual.
    3. Login KAGRA wiki, and press "Edit" button around the top left.
      • Account name and password are shown on the white board in the control room.



1. Interferometer locking status screen

  • Please check the interferometer locking screen at the front monitor in the control room first. If the status is not "LOCKED", something might happen.
  • If FPMI cannot keep "LOCKED" state for over 10 minutes or cannot got back to "LOCKED" state, please contact operator shift.

    IFOstatus_s.png


2. Check list of the interferometer

How to access to the guardian screen

  • On the desktop, you can click the sitemap.

    112.png

  • In the sitemap, you can click on the link for the guardian overview screen.

    116.png

2-1. Check if the LSC_LOCK Guardian at OBSERVATION state

  • Please check the "LSC_LOCK" is in "OBSERVATION" mode. If not, please contact operator shift.

    116.png

2-2. Check if all of VIS Guardians are at ALIGNED state

Look at Guardian Overview

  • VIS guardian.png

OR you can see the VIS status on the Monitor

  • VIS guardian 2.png

  • If the Guardian is at TRIPPED state, you should reset Watch Dogs (WDs), OR call operation shift members (contact person TBD).

2-3. Check the IO Guardian

IO guardian.png

IO Guardian should at PROVIDING_STABLE_LIGHT state, if not call operation shift members ASAP!!!(contact person TBD).

2-4. Check the Green Laser status

  • See if the shutter is on or not. If the background color is green, the shutter is ok/open (red means the shutter is closed).

shutter.png

  • see if K1: ALS-X (Y)_ARM_INPUT_OUT is more than 0.7

0.7.png

2-5. Check if ALS_PLLX/ALS_PLLY Guardian is at PLL_LOCK state

PLLXY1.png


Control Room Overview

  • IFO Monitor: shows the status of the Main Interferometer
  • IFO1.png

  • CCD Monitor:
  • CCD.jpg

  • DAQ/VIS status:
  • vis status.png

  • PEM Monitor: Room temperature/ Vacuum pressure
  • Pem.jpg

  • Time: show JST/UTC/GPS time
  • GPS t ime.jpg

KAGRA/EngineeringRun/ER191217_24/Shift (last edited 2020-04-07 12:03:16 by OsamuMiyakawa)