Differences between revisions 73 and 92 (spanning 19 versions)
Revision 73 as of 2019-12-17 10:06:48
Size: 3150
Comment:
Revision 92 as of 2019-12-17 10:44:22
Size: 4168
Comment:
Deletions are marked like this. Additions are marked like this.
Line 1: Line 1:
= Collaborator shift manual =
  modified at 2019/12/17
= For collaborator shifts =
Line 5: Line 4:
 * [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=10914| Operator Shift]]  * Operator shift table in [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=10914|JGW-M1910914]]
 * Some information for collaborator shifts in [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=9380|JGW-M1809380]]

----
== Collaboration shift routine tasks ==

 1. Write "Log book" on the desk in the control room.
  * Put check mark every 2 hours.
  * Write down everything you noticed.
   * Example: lock lost, earthquake, somebody entered mine etc.
 * When FPMI cannot keep lock state for over 10 minutes or cannot got to lock state
  ---> call operation shift members
   * contact person on the day is listed with '''PHONE NUMBER''' around white board in the control room or see the link [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=10914|JGW-M1910914]] (no phone number in this list)
 * Write down "Takeover note" on the desk in the control room.
  * If you have something which should be known to the next shift, please leave messages in the notebook.
 * Please write [[http://klog.icrr.u-tokyo.ac.jp/osl/|klog]]: [[http://klog.icrr.u-tokyo.ac.jp/osl/]] before you leave control room.
  * Writing [[http://klog.icrr.u-tokyo.ac.jp/osl/|klog]] is very important. This is only one tool which can show the status in the control room to outside.

------
Line 7: Line 24:
 * When FPMI cannot keep lock state for over 10 minutes or cannot got to lock state ---> call operation shift members (contact person TBD).
Line 9: Line 25:
 * Collaboration shift routine tasks

 . <<TableOfContents(2)>>

= Control Room Overview =
== Control Room Overview ==

For collaborator shifts


Collaboration shift routine tasks

  1. Write "Log book" on the desk in the control room.
    • Put check mark every 2 hours.
    • Write down everything you noticed.
      • Example: lock lost, earthquake, somebody entered mine etc.
  2. When FPMI cannot keep lock state for over 10 minutes or cannot got to lock state
    • ---> call operation shift members

      • contact person on the day is listed with PHONE NUMBER around white board in the control room or see the link JGW-M1910914 (no phone number in this list)

  3. Write down "Takeover note" on the desk in the control room.
    • If you have something which should be known to the next shift, please leave messages in the notebook.
  4. Please write klog: http://klog.icrr.u-tokyo.ac.jp/osl/ before you leave control room.

    • Writing klog is very important. This is only one tool which can show the status in the control room to outside.


Control Room Overview

  • IFO Monitor: shows the status of the Main Interferometer
  • IFO1.png

  • CCD Monitor:
  • CCD.jpg

  • DAQ/VIS status:
  • vis status.png

  • PEM Monitor: Room temperature/ Vacuum pressure
  • Pem.jpg

  • Time: show JST/UTC/GPS time
  • GPS t ime.jpg

How to check Guardian

how to use Guardian

Accessing to the guardian screen

  • On the desktop, you can click the sitemap.
  • 112.png

  • In the sitemap, you can click on the link for the guardian overview screen.
  • 116.png

  • Meaning of the background color
  • guardian_explanation.png

Knowing the current state and requested state

  • guardian_howto4.png

How to request a state

  • Click on the gray bar in the middle.
    guardian_howto.png
    Then, choose the desired state.
    guardian_howto2.png

Check list of the interferometer

Check if the LSC_LOCK Guardian at OBSERVATION state

LCSLOCK.png

Check if all of VIS Guardians are at ALIGNED state

Look at Guardian Overview

  • VIS guardian.png

OR you can see the VIS status on the Monitor

  • VIS guardian 2.png

  • If the Guardian is at TRIPPED state, you should reset Watch Dogs (WDs), OR call operation shift members (contact person TBD).

Check the IO Guardian

IO guardian.png

IO Guardian should at PROVIDING_STABLE_LIGHT state, if not call operation shift members ASAP!!!(contact person TBD).

Check the Green Laser status

  • See if the shutter is on or not. If the background color is green, the shutter is ok/open (red means the shutter is closed).

shutter.png

  • see if K1: ALS-X (Y)_ARM_INPUT_OUT is more than 0.7

0.7.png

  • Check if ALS_PLLX/ALS_PLLY Guardian is at PLL_LOCK state

PLLXY1.png