Size: 583
Comment:
|
Size: 607
Comment:
|
Deletions are marked like this. | Additions are marked like this. |
Line 6: | Line 6: |
Each iKAGRA ETM suspension has 4 coils and 4 pico-motors connected. | Each iKAGRA ETM suspension has 4 coils and 4 pico-motors (pitch:1-6, yaw:2-7, z:3-8, y:4-9). |
Line 8: | Line 8: |
If the coil-magnet actuator seems to have a problem, please check 2 things. | If you find a problem about coil-magnet actuator, please check 2 things. |
Line 11: | Line 11: |
Mode Cleaner Suspensions
Each MC suspension has 4 coils and 2 pico-motors (pitch, yaw).
ETM
Each iKAGRA ETM suspension has 4 coils and 4 pico-motors (pitch:1-6, yaw:2-7, z:3-8, y:4-9).
If you find a problem about coil-magnet actuator, please check 2 things.
1. Coil drivers in particular for Y-end had a loose connection with power line (-18V, -15V).
Please check the LED on coil driver. If the LED is out, try to fasten the power line.
2. Sometimes watchdog? system stop the output current from the coil driver in order to protect mechanical system.