Differences between revisions 1 and 2
Revision 1 as of 2019-12-25 13:56:12
Size: 646
Editor: miyoki
Comment:
Revision 2 as of 2019-12-25 13:56:26
Size: 655
Editor: miyoki
Comment:
Deletions are marked like this. Additions are marked like this.
Line 5: Line 5:
 * Please put -26 (<- this value is example) to K1:VIS-SR3_IM_OLSET_P_OFFSET. From terminal, you cando caput K1:VIS-SR3_IM_OLSET_P_OFFSET -26 (<- this value is example)  * Please put -26 (<- this value is an example) to K1:VIS-SR3_IM_OLSET_P_OFFSET. From terminal, you cando caput K1:VIS-SR3_IM_OLSET_P_OFFSET -26 (<- this value is an example)
Line 7: Line 7:
 * Make sure K1:VIS-SR3_TM_OPLEV_PIT_DIAGMON goes to -26 (<- this value is example) . You can check on terminal by caget K1:VIS-SR3_TM_OPLEV_PIT_DIAGMON  * Make sure K1:VIS-SR3_TM_OPLEV_PIT_DIAGMON goes to -26 (<- this value is an example) . You can check on terminal by caget K1:VIS-SR3_TM_OPLEV_PIT_DIAGMON

PR3 DC alignment

  • Make sure VIS_SR3 guardian is ALIGNED. You can check on terminal by guardctrl status VIS_SR3
  • Please put -26 (<- this value is an example) to K1:VIS-SR3_IM_OLSET_P_OFFSET. From terminal, you cando caput K1:VIS-SR3_IM_OLSET_P_OFFSET -26 (<- this value is an example)

  • Make sure K1:VIS-SR3_TM_OPLEV_PIT_DIAGMON goes to -26 (<- this value is an example) . You can check on terminal by caget K1:VIS-SR3_TM_OPLEV_PIT_DIAGMON

  • Make sure green Y arm transmission goes close to 1. Check by caget K1:AOS-TMSY_GR_PDA1_OUTPUT
  • Then you can start LSC_LOCK guardian, or the initial alignment (if it seems necessary)

KAGRA/Operation/Manuals/MIF/VIS/TypeB/PR3/DCAlignmentRecovery (last edited 2019-12-25 16:09:36 by miyoki)