Size: 1205
Comment:
|
Size: 3911
Comment:
|
Deletions are marked like this. | Additions are marked like this. |
Line 5: | Line 5: |
* https://klog.icrr.u-tokyo.ac.jp/osl/?r=29228 | |
Line 7: | Line 8: |
* https://klog.icrr.u-tokyo.ac.jp/osl/?r=29520 | |
Line 9: | Line 11: |
* Did you eyeballs check during the beam path check? | |
Line 12: | Line 15: |
Suspension Health check PR2,3, BS, SRM, SR2, SR3. (Takahashi-san, Ushiba-kun) | Suspension Condition of PR2, PR3, BS, SR3, SR2, SRM. (Takahashi-san, Ushiba-kun, Hirata-san) |
Line 14: | Line 17: |
* Mechanical Motion * Smooth pico motion and its default position: skip * Gaps between magnets and coils :skip * Gaps between EQ stoppers and mirrors * PR2 * (Recovery Work)https://klog.icrr.u-tokyo.ac.jp/osl/?r=28593 * Position measurement of the traverser. * PR3 * (Recovery Work)https://klog.icrr.u-tokyo.ac.jp/osl/?r=28509 * Position measurement of the traverser. * BS * SRM: https://klog.icrr.u-tokyo.ac.jp/osl/?r=29594 * SR2: https://klog.icrr.u-tokyo.ac.jp/osl/?r=29595 * SR3: https://klog.icrr.u-tokyo.ac.jp/osl/?r=29596 *SRMs total comments: https://klog.icrr.u-tokyo.ac.jp/osl/?r=29612 * IP adjustment * BS: https://klog.icrr.u-tokyo.ac.jp/osl/?r=28359 * Electrical wirings * Coil resistances and inductances -> * PR2: https://klog.icrr.u-tokyo.ac.jp/osl/?r=29429 * PR3: https://klog.icrr.u-tokyo.ac.jp/osl/?r=29430 * BS : https://klog.icrr.u-tokyo.ac.jp/osl/?r=29088, https://klog.icrr.u-tokyo.ac.jp/osl/?r=29014 * SRM: * SR2: * SR3: |
|
Line 16: | Line 45: |
* OSEM conditions * RP2: (Recovery Work)https://klog.icrr.u-tokyo.ac.jp/osl/?r=28593 * RP3: (Recovery Work)https://klog.icrr.u-tokyo.ac.jp/osl/?r=28509 * BS : https://klog.icrr.u-tokyo.ac.jp/osl/?r=29156, https://klog.icrr.u-tokyo.ac.jp/osl/?r=29379 * SRM: https://klog.icrr.u-tokyo.ac.jp/osl/?r=29317, https://klog.icrr.u-tokyo.ac.jp/osl/?r=29323, https://klog.icrr.u-tokyo.ac.jp/osl/?r=29594 * SR2: https://klog.icrr.u-tokyo.ac.jp/osl/?r=29315, https://klog.icrr.u-tokyo.ac.jp/osl/?r=29322, https://klog.icrr.u-tokyo.ac.jp/osl/?r=29595 * SR3: https://klog.icrr.u-tokyo.ac.jp/osl/?r=29316, https://klog.icrr.u-tokyo.ac.jp/osl/?r=29321, https://klog.icrr.u-tokyo.ac.jp/osl/?r=29596 * Smooth Mag-coil motion and balance and TFs * Spectrum * PR2: * PR3: * BS: https://klog.icrr.u-tokyo.ac.jp/osl/?r=28292, https://klog.icrr.u-tokyo.ac.jp/osl/?r=28352, https://klog.icrr.u-tokyo.ac.jp/osl/?r=29432 * SRM: https://klog.icrr.u-tokyo.ac.jp/osl/?r=28373, https://klog.icrr.u-tokyo.ac.jp/osl/?r=29584 * SR2: https://klog.icrr.u-tokyo.ac.jp/osl/?r=28369, https://klog.icrr.u-tokyo.ac.jp/osl/?r=29498 * SR3: https://klog.icrr.u-tokyo.ac.jp/osl/?r=28368, https://klog.icrr.u-tokyo.ac.jp/osl/?r=29199 |
|
Line 18: | Line 63: |
* Mirror conditions(??) * Clean around the center? * |
|
Line 59: | Line 107: |
* | * Finished: https://klog.icrr.u-tokyo.ac.jp/osl/?r=29146, https://klog.icrr.u-tokyo.ac.jp/osl/?r=29088, https://klog.icrr.u-tokyo.ac.jp/osl/?r=29146 |
PR2,3,BS,SRM,SR2,SR3 Cleaning
PR2
PR3
No cleaning for BS, SRM, SR2, SR3
- Did you eyeballs check during the beam path check?
Suspension Condition of PR2, PR3, BS, SR3, SR2, SRM. (Takahashi-san, Ushiba-kun, Hirata-san)
- Mechanical Motion
- Smooth pico motion and its default position: skip
- Gaps between magnets and coils :skip
- Gaps between EQ stoppers and mirrors
- PR2
(Recovery Work)https://klog.icrr.u-tokyo.ac.jp/osl/?r=28593
- Position measurement of the traverser.
- PR3
(Recovery Work)https://klog.icrr.u-tokyo.ac.jp/osl/?r=28509
- Position measurement of the traverser.
- BS
SRMs total comments: https://klog.icrr.u-tokyo.ac.jp/osl/?r=29612
- PR2
- IP adjustment
- Electrical wirings
Coil resistances and inductances ->
- OSEM conditions
RP2: (Recovery Work)https://klog.icrr.u-tokyo.ac.jp/osl/?r=28593
RP3: (Recovery Work)https://klog.icrr.u-tokyo.ac.jp/osl/?r=28509
BS : https://klog.icrr.u-tokyo.ac.jp/osl/?r=29156, https://klog.icrr.u-tokyo.ac.jp/osl/?r=29379
SRM: https://klog.icrr.u-tokyo.ac.jp/osl/?r=29317, https://klog.icrr.u-tokyo.ac.jp/osl/?r=29323, https://klog.icrr.u-tokyo.ac.jp/osl/?r=29594
SR2: https://klog.icrr.u-tokyo.ac.jp/osl/?r=29315, https://klog.icrr.u-tokyo.ac.jp/osl/?r=29322, https://klog.icrr.u-tokyo.ac.jp/osl/?r=29595
SR3: https://klog.icrr.u-tokyo.ac.jp/osl/?r=29316, https://klog.icrr.u-tokyo.ac.jp/osl/?r=29321, https://klog.icrr.u-tokyo.ac.jp/osl/?r=29596
- Smooth Mag-coil motion and balance and TFs
- Spectrum
- PR2:
- PR3:
BS: https://klog.icrr.u-tokyo.ac.jp/osl/?r=28292, https://klog.icrr.u-tokyo.ac.jp/osl/?r=28352, https://klog.icrr.u-tokyo.ac.jp/osl/?r=29432
SRM: https://klog.icrr.u-tokyo.ac.jp/osl/?r=28373, https://klog.icrr.u-tokyo.ac.jp/osl/?r=29584
SR2: https://klog.icrr.u-tokyo.ac.jp/osl/?r=28369, https://klog.icrr.u-tokyo.ac.jp/osl/?r=29498
SR3: https://klog.icrr.u-tokyo.ac.jp/osl/?r=28368, https://klog.icrr.u-tokyo.ac.jp/osl/?r=29199
- Mirror conditions(??)
- Clean around the center?
- Clean around the center?
Oplev Check for PR2,3,BS,SRM,SR2,SR3. (Yokozawa-kun)
Activities:
Beam Power
Beam Path Clearance
QPD centering
Calibration
Spectrum Health
Oplev beam's stray light influence
- almost no light?
Oplev table covering
- we will do this after closing.
Beam path and Baffle Position
Leaked hermetic flange repair on BS
Finished: https://klog.icrr.u-tokyo.ac.jp/osl/?r=29146, https://klog.icrr.u-tokyo.ac.jp/osl/?r=29088, https://klog.icrr.u-tokyo.ac.jp/osl/?r=29146
Vacuum system (Kimura/Uchiyama and their selected persons)
Clean inside as much as possible including the bellows duct with TMP
- maybe impossible from the only side hatches.
Check the flange seal surface condition where were opened.
Decide where the elastomer/Metal gasket will be used.
Check the opened flanges and the top hut of PRM2, 3
Logistic to reinstall the bellows duct with TMP.
- Sawada-sana and Mirapro members call
- If you use chain block, please be careful of its fixing
- Careful cramp tightening near oplevs.