Size: 4212
Comment:
|
← Revision 12 as of 2019-05-08 16:15:06 ⇥
Size: 4495
Comment:
|
Deletions are marked like this. | Additions are marked like this. |
Line 1: | Line 1: |
= Transmission Monitor's Vibration Isolation Stage for Y (TMS-VISY): preparation in Mitaka = | = TMS-VIS-Y: preparation in Mitaka = |
Line 4: | Line 4: |
||<<MonthCalendar(,2019,5)>>||<<MonthCalendar(,2019,6)>>||<<MonthCalendar(,2019,7)>>|| | |
Line 7: | Line 8: |
* [[hKAGRA/subgroup/AOS/TMS-VIS0|The previous preparation of TMS-VIS (for Xend)]] | * [[KAGRA/subgroup/AOS/TMS-VIS0|The previous preparation of TMS-VIS (for Xend)]] |
Line 22: | Line 23: |
||'''Sensor'''|| Serial#|| polarity || calibration factor || || LVDT V1 ||# || || || || LVDT V2 ||# || || || || LVDT V3 ||# || || || || LVDT H1 ||# || || || || LVDT H2 ||# || || || || LVDT H3 ||# || || || |
||'''Sensor'''|| Serial#|| polarity || calibration factor [um/cnt]|| || LVDT V1 ||#6 ||-1 ||0.1374 || || LVDT V2 ||#8 ||+1 ||0.1463 || || LVDT V3 ||#9 ||+1 ||0.1456 || || LVDT H1 ||#10 ||-1 ||0.1356 || || LVDT H2 ||#11 ||-1 ||0.1371 || || LVDT H3 ||#12 ||+1 ||0.1473 || |
Line 43: | Line 44: |
|| COIL V1 || ||# || || COIL V2 || ||# || || COIL V3 || ||# || || COIL H1 || ||# || || COIL H2 || ||# || || COIL H3 || ||# || |
|| COIL V1 ||+ ||#13 || || COIL V2 ||+ ||#15 || || COIL V3 ||+ ||#16 || || COIL H1 ||+ ||#17 || || COIL H2 ||+ ||#1 || || COIL H3 ||+ ||#6 || |
Line 55: | Line 56: |
|| 404080975 || Vert || || || || 404080976 || Vert || TMS-VISX: Geo-V2|| Akutsu || |
|| 404080975 || Vert || TMS-VISY: Geo-V2||Akutsu || || 404080976 || Vert || -(TMS-VISX: Geo-V2)-|| Akutsu || |
Line 58: | Line 59: |
|| 404080978 || Vert || || || || 404084240 || Vert || || || || 404084241 || Vert || TMS-VISX: Geo-V3|| Akutsu || || 404084242 || Vert || TMS-VISX: Geo-V1|| Fujii -> Akutsu || || 2 || Horiz|| TMS-VISX: Geo-H3|| Akutsu -> Uraguchi || |
|| 404080978 || Vert || TMS-VISY: Geo-V3||Akutsu || || 404084240 || Vert || TMS-VISY: Geo-V1 (broken??)|| Akutsu || || 404084241 || Vert || -(TMS-VISX: Geo-V3)-|| Akutsu || || 404084242 || Vert || -(TMS-VISX: Geo-V1)-|| Fujii -> Akutsu || || 2 || Horiz|| -(TMS-VISX: Geo-H3)-|| Akutsu -> Uraguchi || |
Line 64: | Line 65: |
|| 4 || Horiz|| TMS-VISX: Geo-H1|| Akutsu || || 5 || Horiz|| TMS-VISX: Geo-H2|| Akutsu || || 15 || Horiz|| || || || 16 || Horiz|| || || || 17 || Horiz|| || || |
|| 4 || Horiz|| -(TMS-VISX: Geo-H1)-|| Akutsu || || 5 || Horiz|| -(TMS-VISX: Geo-H2)-|| Akutsu || || 15 || Horiz|| TMS-VISY: Geo-H1|| Akutsu || || 16 || Horiz|| TMS-VISY: Geo-H2|| Akutsu || || 17 || Horiz|| TMS-VISY: Geo-H3|| Akutsu || |
TMS-VIS-Y: preparation in Mitaka
- TMS = BRT (beam reducing telescope) + GPT (Gouy phase telescope)
|
|
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
|
Links to knowledge
Mechanical design: Mechanical design of TMS Vibration Isolation Stage (by Uraguchi-san)
Ref: design of blade spring for TMS VIS stage (in Japanese) (by Uraguchi-san)
Ref: mechanical model of TMS VIS (in Japanese) (by Uraguchi-san)
LVDTs
Polarity & Calibration Factor
- V: postive means that the LVDT outputs positive counts when TMS-VIS moves upward, and so the calibration factors are set.
- H: postive means that the LVDT outputs positive counts when TMS-VIS moves positive yaw (counter clock wise from top view), and so the calibration factors are set.
Sensor |
Serial# |
polarity |
calibration factor [um/cnt] |
LVDT V1 |
#6 |
-1 |
0.1374 |
LVDT V2 |
#8 |
+1 |
0.1463 |
LVDT V3 |
#9 |
+1 |
0.1456 |
LVDT H1 |
#10 |
-1 |
0.1356 |
LVDT H2 |
#11 |
-1 |
0.1371 |
LVDT H3 |
#12 |
+1 |
0.1473 |
Actuator coils
Be careful! The pin assignment in the Dsub shell or the signal phases would be different from the below, as I needed to once detach the pins when I installed the coils (Akutsu). Note that newly four actuator coils have been made for TMS-VISY after JGW-T1800846.
- [[]]
- Tanioka-kun's efforts in 2019
Polarity & Calibration Factor
- V: postive means upward (TMS-VIS moves in upward by inputting positive value to the act coils from MEDM)
- H: positive means plus yaw (TMS-VIS moves in counter clock wise from top view by inputting positive value to the act coils from MEDM)
Actuator |
polarity |
Serial# |
COIL V1 |
+ |
#13 |
COIL V2 |
+ |
#15 |
COIL V3 |
+ |
#16 |
COIL H1 |
+ |
#17 |
COIL H2 |
+ |
#1 |
COIL H3 |
+ |
#6 |
Geophones
Serical# of L-4C |
Vert/Horiz |
Naming of the assembled unit |
Assembler |
404080975 |
Vert |
TMS-VISY: Geo-V2 |
Akutsu |
404080976 |
Vert |
-(TMS-VISX: Geo-V2)- |
Akutsu |
404080977 |
Vert |
|
|
404080978 |
Vert |
TMS-VISY: Geo-V3 |
Akutsu |
404084240 |
Vert |
TMS-VISY: Geo-V1 (broken??) |
Akutsu |
404084241 |
Vert |
-(TMS-VISX: Geo-V3)- |
Akutsu |
404084242 |
Vert |
-(TMS-VISX: Geo-V1)- |
Fujii -> Akutsu |
2 |
Horiz |
-(TMS-VISX: Geo-H3)- |
Akutsu -> Uraguchi |
3 |
Horiz |
|
|
4 |
Horiz |
-(TMS-VISX: Geo-H1)- |
Akutsu |
5 |
Horiz |
-(TMS-VISX: Geo-H2)- |
Akutsu |
15 |
Horiz |
TMS-VISY: Geo-H1 |
Akutsu |
16 |
Horiz |
TMS-VISY: Geo-H2 |
Akutsu |
17 |
Horiz |
TMS-VISY: Geo-H3 |
Akutsu |
Cabling
- LVDT/Act - (coil wires) - Dsub9M - (Dsub9F - PTFE 2m - Dsub9F) - Dsub9M flange - Flipper cable - Dsub Cable
- Geophone - (MIL C 26482 - PTFE 0.5m - Dsub9M) - (Dsub9F - 1.5m PTFE - Dsub9F) - Dsub9M flange - Flipper cable - Dsub Cable