JGW Logo
  • Login
  • KAGRA
  • Subgroups
  • DET
  • Meeting
  • 230308
  • RecentChanges
  • FindPage
  • HelpContents
  • 230308

Revision 1 as of 2023-03-08 10:48:36

Clear message
  • Immutable Page
  • Comments
  • Info
  • Attachments
  • PRFPMI with OMC DC readout
    • 1.2 W output from IMC (7 W when O3GK)
    • Noise hunting
      • (ongoing) MICH/PRCL feed forward tuning
      • (ongoing) Turning off the instruments (Especially vacuum pumps(TMP))
      • Investigating the noise from the vibration
        • OMC leg
        • IMC
        • IFI
        • etc
      • We opened the IFI chamber and remove the material which was connected between IFI chamber and IFI optical table in vac
        • Motivation was to extract the thermal from PRM reflection beam
        • After this work, the sensitivity is improved
        • Latest sensitivity wiki

    • Silent run
      • Latest one klog24301

    • Future work
      • Evaluate the noise budget
        • Turned off the instruments
        • Check the scattering light
        • Hammering test/Acustic injection
      • Suspension control optimization
      • Alignment sensing and control
        • ADS and ASC
      • Interferometer characterization
      • Increased the laser power
  • Immutable Page
  • Comments
  • Info
  • Attachments
  • MoinMoin Powered
  • Python Powered
  • GPL licensed
  • Valid HTML 4.01