⇤ ← Revision 1 as of 2020-06-04 18:18:24
Size: 1084
Comment:
|
Size: 1568
Comment:
|
Deletions are marked like this. | Additions are marked like this. |
Line 9: | Line 9: |
6/2: O3GK configuration file is following. [[https://github.com/gw-detchar/tools/blob/master/Omicron/Parameter/O3rerun_4096.txt]] [[https://github.com/gw-detchar/tools/blob/master/Omicron/Parameter/O3rerun_2048.txt]] [[https://github.com/gw-detchar/tools/blob/master/Omicron/Parameter/O3rerun_1024.txt]] [[https://github.com/gw-detchar/tools/blob/master/Omicron/Parameter/O3rerun_512.txt]] [[https://github.com/gw-detchar/tools/blob/master/Omicron/Parameter/O3rerun_256.txt]] |
O3GK reprocess log
This is log of problems and solutions during O3GK reprocess. You can get some plots used in following struggling here
6/2: O3GK configuration file is following. https://github.com/gw-detchar/tools/blob/master/Omicron/Parameter/O3rerun_4096.txt https://github.com/gw-detchar/tools/blob/master/Omicron/Parameter/O3rerun_2048.txt https://github.com/gw-detchar/tools/blob/master/Omicron/Parameter/O3rerun_1024.txt https://github.com/gw-detchar/tools/blob/master/Omicron/Parameter/O3rerun_512.txt https://github.com/gw-detchar/tools/blob/master/Omicron/Parameter/O3rerun_256.txt
Some channels had error message like Omicron::ExtractTriggers: the maximum trigger rate (5000.00000 Hz) is exceeded
Case 1: At the lock loss
- ex. K1:CAL-CS_PROC_DARM_DISPLACEMENT_DQ, K1:LSC-MICH_IN1_DQ
-> Solution: The last 30 sec of segment is not used in Omicron.
Case 2: Appearance or disappearance of line noise
- ex. K1:PEM-MIC_OMC_TABLE_AS_Z_OUT_DQ, K1:PEM-MAG_EXC_BOOTH_EXC_Y_OUT_DQ
-> Solution: Reprocess Omicron with only failed short segments.
Case 3: Unused channels
- ex. K1:IMC-IMMT1_TRANS_QPDA2_DC_PIT_OUT_DQ, K1:LSC-REFL_PDA2_DC_OUT_DQ
-> Solution: Skip these channels
Case 4: Strange behavior
- ex. K1:AOS-TMSX(Y)_GR_(Q)PDA1_(SUM_)OUT_DQ, K1:OMC-PZT_LV_OUT_DQ
-> Solution: Skip these channels (We may better to investigate them )