## page was renamed from LCGT/subgroup/ifo/digital/Manual/ChangeModelNameSTDA |
How to change model name or DCU number on standalone setpu.
- Make a new .mdl RT model file using Simlink of Matlab or copy the existing .mdl file under /opt/rtcds/tst/x1/core/advLigoRTS/trunk/src/epics/simLink/.
- If you want to change druid on an existing model, start matlab on 'desktop1' PC, open the x1x30.mdl, and change dcuid on left top box.
Go RT PC as
ssh -Y XXX
(XXX = RT PC host name like standalone)> cd /opt/rtcds/tst/x1/core/advLigoRTS/trunk
build model as
> ./dbuild xxx.mdl
(xxx = model name like x1scx)- Verify no error message
- Then modify /etc/rtsystab to put the new model name or change existing model to the new one.
- Modify /opt/rtcds/tst/x1/target/fb/master
- And /opt/rtcds/tst/x1/target/fb/daqdrc if you changed DUC number.
- /opt/rtcds/tst/x1/target/gds/param/testpoint.par should be modified automatically when you build.
define and activate DAQ channels using
> daqconfig &
kill old model like
> killyyy
(yyy = existing old model name like x1x15) and start the new model by typing
> startxxx
(xxx = model name like x1scx) on any directly, or just reboot RT PC as