*[[http://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=4822|Slide of JPS meeting in March 22nd 2015 written by Kataoka]]  *[[http://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=4822|Slide of JPS meeting in March 22nd 2015 written by Kataoka]]

Input Faraday Isolator

Basic Configuration

Parameter of IFI

  • Weight : 18.1kg
  • Size : L=647.7mm, W=177.8mm, H=155.9mm (with bread bord) IFI Drawing

The hight of IFI is different from CAD file

Parameter of baseplate of IFI

Current Status

  • IFI was purchased from UF
  • IFI was completed to Assemble on the PSL table in 2015/11
  • Installation was completed in 2015/11
  • Alignment was completed in 2016/02
  • IFI will not be suspended but directly put on the IFI table
  • A pair of unsuspended steering mirrors (STM) have been used for the beam centering

Pending Problems

  • Total hight of IFI system ( = IFI + Baseplate) is higher than the designed beam hight by 1cm.
  • Is CWP2 replacement needed ?
  • How we test IFI in high power.
  • How to measure the scattering light from IFI and how to dump that ?
  • Connecting IFI to the digital system.
  • Is installing counter masses needed ?