Size: 245
Comment:
|
← Revision 16 as of 2016-03-22 22:37:39 ⇥
Size: 3297
Comment:
|
Deletions are marked like this. | Additions are marked like this. |
Line 2: | Line 2: |
Overview of IFI written by K. Somiya[[http://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=3537|IFI report]] Proposal for KAGRA IO Faraday Isolator written by G. Muller and D.B. Tanner [[http://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=3461|Proposal for KAGRA IO Faraday Isolator]] = Basic Configuration = *IFI is seated on the baseplate because the beam hight of KAGRA is different from aLIGO. *Ray tracing was calculated by K. Yano [[http://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=4233|Current ray trace around the IFI]] == Parameter of IFI == * Weight : 18.1kg * Size : L=647.7mm, W=177.8mm, H=155.9mm (with bread bord) [[http://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=3538|IFI Drawing]] {{{#!wiki red/solid'''ATTENTION!''' The hight of IFI is different from CAD file}}} == Parameter of baseplate of IFI == * Weight : 26.9kg * Size : L=630mm, W=250mm, H=64.1mm [[http://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=4161|Base of the IFI Drawing]] = Current Status = * IFI was purchased from UF * IFI was completed to Assemble on the PSL table in 2015/11 * Installation was completed in 2015/11 * Alignment was completed in 2016/02 * IFI will not be suspended but directly put on the IFI table * A pair of unsuspended steering mirrors (STM) have been used for the beam centering |
|
Line 3: | Line 24: |
[[http://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=2104|Report by Kentaro]] (2014/1) | === Pending Problems === * Total hight of IFI system ( = IFI + Baseplate) is higher than the designed beam hight by 1cm. * Is CWP2 replacement needed ? * How we test IFI in high power. * How to measure the scattering light from IFI and how to dump that ? * Connecting IFI to the digital system. * Is installing [[http://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=4551|counter masses]] needed ? |
Line 5: | Line 32: |
[[http://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=2486|IFI Layout]] (2014/6) | == Related documents == *[[http://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=4822|Slide of JPS meeting in March 22nd 2016 written by Kataoka]] *[[http://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=4822|Slide in 13th f2f meeting written by Kataoka]] *[[http://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=3440|Slide of JPS meeting in March 21st 2015 written by Kataoka]] * [[http://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=3295|Slide in 11th f2f meeting written by Yano]] * [[http://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=3460|measurement result in Dec.2014]] * [[http://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=2104|First Report by Somiya in 2014/1]] * [[http://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=2192|Magnetic noise estimation by Somiya]] * [[http://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=2227|Scatter-light noise estimation by Somiya]] * [[http://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=2330|Apperture noise estimation by Somiya]] * [[http://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=2486|IFI Layout by Somiya]] * [[http://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=2474|STM noise by Nakano]] |
Input Faraday Isolator
Overview of IFI written by K. SomiyaIFI report
Proposal for KAGRA IO Faraday Isolator written by G. Muller and D.B. Tanner Proposal for KAGRA IO Faraday Isolator
Basic Configuration
- IFI is seated on the baseplate because the beam hight of KAGRA is different from aLIGO.
Ray tracing was calculated by K. Yano Current ray trace around the IFI
Parameter of IFI
- Weight : 18.1kg
Size : L=647.7mm, W=177.8mm, H=155.9mm (with bread bord) IFI Drawing
The hight of IFI is different from CAD file
Parameter of baseplate of IFI
- Weight : 26.9kg
Size : L=630mm, W=250mm, H=64.1mm Base of the IFI Drawing
Current Status
- IFI was purchased from UF
- IFI was completed to Assemble on the PSL table in 2015/11
- Installation was completed in 2015/11
- Alignment was completed in 2016/02
- IFI will not be suspended but directly put on the IFI table
- A pair of unsuspended steering mirrors (STM) have been used for the beam centering
Pending Problems
- Total hight of IFI system ( = IFI + Baseplate) is higher than the designed beam hight by 1cm.
- Is CWP2 replacement needed ?
- How we test IFI in high power.
- How to measure the scattering light from IFI and how to dump that ?
- Connecting IFI to the digital system.
Is installing counter masses needed ?