Differences between revisions 8 and 10 (spanning 2 versions)
Revision 8 as of 2014-06-29 18:45:27
Size: 1040
Comment:
Revision 10 as of 2016-03-10 04:10:27
Size: 2669
Editor: YuKataoka
Comment:
Deletions are marked like this. Additions are marked like this.
Line 2: Line 2:
 Overview of IFI was written by K. Somiya[[http://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=3537|IFI report]]
= Basic Configuration =
 *IFI is seated on the baseplate because the beam hight of KAGRA is different from aLIGO.
 *Ray tracing was calculated by K. Yano [[http://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=4233|Current ray trace around the IFI]]
== Parameter of IFI ==
 * Weight : 18.1kg
 * Size : L=647.7mm, W=177.8mm, H=155.9mm (with bread bord) [[http://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=3538|IFI Drawing]]
== Parameter of baseplate of IFI ==
 * Weight : 26.9kg
 * Size : L=630mm, W=250mm, H=64.1mm [[http://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=4161|Base of the IFI Drawing]]
= Current Status =
 * IFI was purchased from UF
 * IFI was completed to Assemble on the PSL table in 2015/11
 * Installation was completed in 2015/11
 * Alignment was completed in 2016/02
 * IFI will not be suspended but directly put on the IFI table
 * A pair of unsuspended steering mirrors (STM) have been used for the beam centering
Line 3: Line 20:
 * IFI will be purchased from UF
 * Assembly on the PSL table is scheduled in 2014/11
 * Installation will be in 2015/3
 * IFI will not be suspended but directly put on the IFI table
 * A pair of unsuspended steering mirrors (STM) will be used for the beam centering
=== Pending Problems ===
 * Total hight of IFI system ( = IFI + Baseplate) is higher than the designed beam hight by 1cm.
 * Is CWP2 replacement needed ?
 * Is install counter masses needed ?
 * How we test IFI in high power.
Line 10: Line 27:
 *[[http://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=4822|Slide in 13th f2f meeting written by Kataoka]]
 *[[http://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=4542|Slide of JPS meeting in March 21st 2015 written by Kataoka]]
 * [[http://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=3295|Slide in 11th f2f meeting written by Yano]]
 * [[http://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=3460|measurement result in Dec.2014]]

Input Faraday Isolator

  • Overview of IFI was written by K. SomiyaIFI report

Basic Configuration

Parameter of IFI

  • Weight : 18.1kg
  • Size : L=647.7mm, W=177.8mm, H=155.9mm (with bread bord) IFI Drawing

Parameter of baseplate of IFI

Current Status

  • IFI was purchased from UF
  • IFI was completed to Assemble on the PSL table in 2015/11
  • Installation was completed in 2015/11
  • Alignment was completed in 2016/02
  • IFI will not be suspended but directly put on the IFI table
  • A pair of unsuspended steering mirrors (STM) have been used for the beam centering

Pending Problems

  • Total hight of IFI system ( = IFI + Baseplate) is higher than the designed beam hight by 1cm.
  • Is CWP2 replacement needed ?
  • Is install counter masses needed ?
  • How we test IFI in high power.

KAGRA/Subgroups/IOO/IFI (last edited 2016-03-22 22:37:39 by YuKataoka)