Line 105: Line 105:
  * Perhaps interesting to lock OMC to check out the freq/int noise couplings to AS port.   * Perhaps interesting to lock OMC to check out the freq/int noise couplings (down to ~10 Hz) to AS port.
Line 123: Line 123:
 * Measure frequency/intensity noise coupling, down to ~10 Hz.
 * Measure MICH/PRCL to DARM coupling.
Line 132: Line 134:
 * Measure MICH/PRCL/SRCL to DARM coupling.

O4 Commissioning Task List

This is a list of things to do for each commissioning stage for O4.

Each stage include ASC.

References

Preparations

  • Tune f1, f2, f3 frequencies to IMC FSR
  • Replace all the in-vac steering mirrors and pick-off mirrors to proper ones JGW-T2112592

  • Replace all the beam splitters in in-air optical tables to non-polarizing beam splitters JGW-D2112956

    • This is necessary to estimate the polarization content of the interferometer correctly (without too much confusion)
  • Install polarization optics to backward POP or POS, and TRY and TRY.
    • This is necessary to estimate the arm cavity round-trip loss correctly JGW-T2011633

  • Check actuation efficiencies of IMC mirrors, frequency actuation efficiencies of PSL.
  • Install picomotor+PZT steering mirrors for POP green and POS green.
  • Install coil driver switch for ETMs (and ITMs?).
    • High power for lock acquisition, low power for low noise mode.
  • Install picomotors to center the beam on oplev QPDs and ASC QPDs.
  • Inject a fake RF signal to PDA1 to reproduce the spurious coupling around the REFL table and ALS racks
    • klogs 10958,10959, 11014, 11315, 12382, 12392,
    • Perhaps illuminating PDA1 by intensity modulated light maybe interesting.
    • Insert Baluns as necessary.

Xarm

  • Measure the finesse at room temperature and at cryogenic temperatures, for both 1064 nm and 532 nm.
  • Measure the round-trip loss by taking into account the effect of birefringence correctly.
    • Measure the beam spot position dependence.
  • Measure the amount of POP/POS p-pol when the arm is locked and unlocked.
  • Measure the mode-matching for both 1064 nm and 532 nm.
  • Tune the Gouy phase separation between two QPDs at REFL/AS/TRX.
    • Make sure all the signals are in in-phase.
  • Measure the alignment sensing matrix at REFL/AS/TRX, for ITM and ETM.
    • Try closing ASC loops.
  • Measure modulation depths for f1, f2 and f3.
  • Check ITM and ETM actuation efficiencies.
  • Make a power budget of each ISC detection port.
  • Refining the automation -- mainly for the successive full ifo initial alignment.
  • Leave a record on the demod phases -- for repeating the Schnup asymmetry measurement.
  • Establish IR/Green co-alignment procedure -- for full ifo initial alignment.
  • Could we check out the common mode servo board at this point?

Yarm

  • Same as Xarm.

Michelson

  • Check BS actuation efficiency.
  • Check out the LSC optical gain. Should be easy enough to doublecheck.
  • Measure, again, the contrast defect.
  • Measure the mode content of AS beam using OMC.
  • Record typical Mich length noise.
  • Close the ASC loops -- mainly for the purpose of the initial alignment automation.
  • Refine the automation.

Power recycling cavity

  • Measure PRY length and PRX length.
    • Previous methods give inconsistent results and also not compatible with Schnupp asymmetry measurements.
  • Tune IMC length to PRC length (and re-tune sideband frequencies).
  • Check actuation efficiency of PR mirrors.
  • Measure PRC Gouy phase.
  • Close the ASC loops.
  • Refine the automation.
  • Check out the power build up in the carrier-locked and side-band locked conditions
  • Correlation measurement of p/s-pol sloshing (https://klog.icrr.u-tokyo.ac.jp/osl/?r=9333) against angular fluctuations or whatever.

  • Identification of any drifty suspensions as the carrier is locked -- to support the coming full lock operation.
  • Tune up the triggers and filter shapes for fast lock acquisition.

Signal recycling cavity

  • Check actuation efficiency of SR mirrors.
  • Measure SRC Gouy phase.
  • Automation?

Dual Recycled Michelson

  • Measure power recycling gains for carrier and sidebands, with and without SRC.
  • Measure length sensing matrix.
    • Both for 1f and 3f signals.
    • Optimize the modulation depths if necessary for sufficient signal-to-noise ratio for 3f signals.
  • Measure power at each ISC detection port when DRMI is locked.
  • Tune the Gouy phase separation between two QPDs at POP.
  • Measure the alignment sensing matrix at REFL/POP/AS.
    • Try closing ASC loops.
    • Most notably the f1-f2 WFSs at AS
  • Examine the mode-hop criteria (https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=12213)

    • Which mirror affects most and how much angular motions are tolerable?
    • Is the SRC Gouy phase large enough?
  • Refine automation.
  • Make a noise budget for MICH/PRCL/SRCL.

Fabry-Perot Michelson

  • Measure length sensing matrix.
  • Measure power at each ISC detection port when FPMI is locked.
  • Measure the alignment sensing matrix at REFL/POP/AS/TRX/TRY.
    • Try closing ASC loops.
    • Test out the radiation pressure basis actuation scheme
  • Do some noise hunting at low frequencies and VIS commissioning with FPMI
    • Perhaps interesting to lock OMC to check out the freq/int noise couplings (down to ~10 Hz) to AS port.
    • Also, rf phase and amp noises.
  • Measure the contrast defect, compare it with Michelson.
  • Measure the mode content of AS beam using OMC, compare it with Michelson.
  • OMC ASC commissioning?
  • Repeat the same measurements as described in
    • klogs 10958,10959, 11014, 11315, 12382, 12392,
    • to make sure whether the problem still persists or not.

Power Recycled Fabry-Perot Michelson

  • Measure length sensing matrix.
  • Measure power recycling gains for carrier and sidebands.
  • Measure power at each ISC detection port when PRFPMI is locked.
  • Measure the alignment sensing matrix at REFL/POP/AS/TRX/TRY.
    • Try closing ASC loops.
  • Refine automation.
    • Review/refine the O3GK lock acquisition process.
  • Measure frequency/intensity noise coupling, down to ~10 Hz.
  • Measure MICH/PRCL to DARM coupling.

Resonant Sideband Extraction

  • Measure length sensing matrix.
  • Measure power recycling gains for carrier and sidebands.
  • Measure the cavity pole.
  • Measure power at each ISC detection port when PRFPMI is locked.
  • Measure the alignment sensing matrix at REFL/POP/AS/TRX/TRY.
    • Try closing ASC loops.
  • Measure MICH/PRCL/SRCL to DARM coupling.