* December 17-24 24h engineering run * [[http://gwwiki.icrr.u-tokyo.ac.jp/JGWwiki/KAGRA/EngineeringRun/ER191217_24/ | wiki]] * We also held the post ER. We turned off the FFUs and vacuum pumps * Lock acquisition to PRFPMI * There is still some peaks in the lower frequency * Type-A resonant frequency [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=11116|JGWDoc11116]] * Peaks appeared at higher frequency * PEM injection to REFL table * After that, we will move to noise hunting |
* Finally, we can lock the PRFPMI * Transmittance laser power became 100 times higher than FPMI * Lock duration is about 30min at maximum * OMC commissioning is also ongoing |
Line 23: | Line 18: |
* PEM plan January * Identification of the ~100Hz noise source * (Maybe, ) the dominant noise for lower frequency may come from suspension * After the success of the PRFPMI (or chance to operate the FPMI), we would like to do following things * Understanding the coupling function detected at the refl table * At the some point, we detected the larger coupling function * Periscope or some optics? * We would like to inject sound or vibration to AS, POP and TMS table |
* New PEMs * We bought the ACO power supply, microphone and accelerometers(end of Feb.) * Basically the portable PEMs * PEM plan * PEM injection to optical table * Hammering test |
Weekly PEM meeting
- 2020/01/28(Tue) 16:00-(JST)
- Regular meeting meeting (Japanese)
Web meeting with Zoom2 (Zoom2)
Agenda
General issue
- Interferometer status
- Finally, we can lock the PRFPMI
- Transmittance laser power became 100 times higher than FPMI
- Lock duration is about 30min at maximum
- OMC commissioning is also ongoing
~100Hz noise and line noise of the higher frequency -> PEM
- Finally, we can lock the PRFPMI
- New PEMs
- We bought the ACO power supply, microphone and accelerometers(end of Feb.)
- Basically the portable PEMs
- PEM plan
- PEM injection to optical table
- Hammering test
- Long term PEM evaluation
- PEM festival
- 01/14(Tue) 9:00-15:00
Evaluate the scattered light for payload (with CRY team) http://klog.icrr.u-tokyo.ac.jp/osl/?r=12293
- 01/15(Wed) (Maybe expanded)
- Turned off almost all FFUs and vacuum pumps
- 01/14(Tue) 9:00-15:00
- Conference
地下宇宙若手研究会@茂住 (2/22-24)
- JPS (2020/3/16-19 @ Nagoya)
- Yokozawa, TTanaka
- KIW7
- PEM injection
- Shaker injection1 (TTanaka, Yokozawa)
- acoustic injection (TTanaka, Yokozawa)
- PSL, REFL and AS table injection
- Analysis is ongoing
- magnetic field injection (Niigata Tanaka, Fujikawa, Yokozawa)
- Effect of the air cooler magnetic field
- AS, REFL table injection
- He is writing the thesis
- Newtonian noise measurement
- Thank you for Virgo PEM member!
- Francesca mainly measured the newtonian noise
- We will discuss in 21st. Jan.(Virgo KAGRA PEM meeting)
- PEM measurement
- Someday : Effect of the sound to DARM displacement
- Someday : Environmental check around BS (including the POP)
- Someday : Evaluation of the table cover
- Someday : SR2 and SR3 optical lever (Reflection light from SRM?)
Each progress
- Yokozawa
- Planning toward the O3 run
- Washimi
Preparation for the hammering test @ Y-end klog
Sound reverberation study (KAGRA & Virgo)
- Kozakai
- Offline detchar report for the part of the PEM
- TTanaka(ICRR)
shaker injection with FPMIspeaker@12/8,shaker@12/15
Master thesisthesis
- Fujikawa
- Lock loss study2
- fujimopy
- TTanaka(Niigata)
- Magnetic field from air cooler and compressor