Cryocooler P53
measured near Cryocooler P53 jpg
measured in 6 situations
situation |
small cryocooler |
big cryocooler |
FFU filters & fan for EXC chamber |
1 |
off |
off |
on |
2 |
on |
off |
on |
3 |
on |
on |
on |
4 |
on |
on |
off |
5 |
off |
off |
off |
Situation 6 is situation 5 with an ele-mag protection sheet
situation 1
0-250 MHz |
0-20 MHz |
0-5 MHz |
situation 2
0-250 MHz |
0-20 MHz |
0-5 MHz |
situation 3
0-250 MHz |
0-20 MHz |
0-5 MHz |
situation 4
0-250 MHz |
0-20 MHz |
0-5 MHz |
situation 5
0-250 MHz |
0-20 MHz |
0-5 MHz |
situation 6
0-250 MHz |
0-20 MHz |
0-5 MHz |