Size: 2537
Comment:
|
← Revision 6 as of 2021-03-03 18:14:28 ⇥
Size: 2743
Comment:
|
Deletions are marked like this. | Additions are marked like this. |
Line 4: | Line 4: |
||<<MonthCalendar(,2021,3)>>| | |
Line 34: | Line 35: |
P23 | P23, to be connected to Cryocon#7 E and F in this order respectively. |
Line 36: | Line 37: |
||A||75 ohm|| Thermometer || V- || Green || || || ||B||75 ohm|| Thermometer || V+ || Black || || || ||C||4 ohm|| Thermometer || I- || Red || || || ||D||4 ohm|| Thermometer || I+ || Yellow || || || ||E||75 ohm|| Thermometer || V- || Green || || || ||F||75 ohm|| Thermometer || V+ || Black || || || ||G||4 ohm|| Thermometer || I- || Red || || || ||H||4 ohm|| Thermometer || I+ || Yellow || || || |
||A||75 ohm|| Thermometer S/N#2564|| V- || Green || WAB || || ||B||75 ohm|| Thermometer S/N#2564|| V+ || Black || WAB || || ||C||4 ohm|| Thermometer S/N#2564|| I- || Red || WAB || || ||D||4 ohm|| Thermometer S/N#2564|| I+ || Yellow || WAB || || ||E||75 ohm|| Thermometer S/N#360|| V- || Green || Structure || || ||F||75 ohm|| Thermometer S/N#360|| V+ || Black || Structure || || ||G||4 ohm|| Thermometer S/N#360|| I- || Red || Structure || || ||H||4 ohm|| Thermometer S/N#360|| I+ || Yellow || Structure || || |
Wide Angle Baffle at IYC
|
|
|
|
||
<< < 2021 / 3 > >> | ||||||
---|---|---|---|---|---|---|
Mon | Tue | Wed | Thu | Fri | Sat | Sun |
1 | 2 | 3 | 4 | 5 | 6 | 7 |
8 | 9 | 10 | 11 | 12 | 13 | 14 |
15 | 16 | 17 | 18 | 19 | 20 | 21 |
22 | 23 | 24 | 25 | 26 | 27 | 28 |
29 | 30 | 31 |
Links to knowledge
Calculations regarding the back-scattering of different Wide Angle Baffle designs (Zeidler)
Personal calc of WAB's stray light noise by Akutsu; due to several uncertain parameters there are several results and no one would know the actual effect!
Heat links positions (by Obuchi) fmkopgehpapgdkcc.png
Task list
Note: some of the tasks can be done in parallel.
Place/install the WAB suspension
Align the position of WAB -> take WAB back to nominal position, put off protectors)
horizontal alignment
yaw alignment
Move it to the saving mode.
Back to the nominal position.
Attach heat links
4 soft heat links to WAB
1 heat link btwn the top and the structure
Attach 2 thermometers
- Set revised blocks under the base plate.
Pin Assignment
P23, to be connected to Cryocon#7 E and F in this order respectively.
Pin Name |
Resistance |
Equipment |
Assign |
Comment1 |
Comment2 |
Connection |
A |
75 ohm |
Thermometer S/N#2564 |
V- |
Green |
WAB |
|
B |
75 ohm |
Thermometer S/N#2564 |
V+ |
Black |
WAB |
|
C |
4 ohm |
Thermometer S/N#2564 |
I- |
Red |
WAB |
|
D |
4 ohm |
Thermometer S/N#2564 |
I+ |
Yellow |
WAB |
|
E |
75 ohm |
Thermometer S/N#360 |
V- |
Green |
Structure |
|
F |
75 ohm |
Thermometer S/N#360 |
V+ |
Black |
Structure |
|
G |
4 ohm |
Thermometer S/N#360 |
I- |
Red |
Structure |
|
H |
4 ohm |
Thermometer S/N#360 |
I+ |
Yellow |
Structure |
|
Note that the pin arrangement (or the naming) is mirrored compared with that of in IXC! Rather, I guess this IXC's would be correct.